OSHA SearchOSHA records by employer

Luis Lara: OSHA inspections and violations

Fort Worth, Texas · Finish Carpentry Contractors · NAICS 238350

2inspections
4citation items
$11,918current penalties
Mar 12, 2025last inspection

OSHA has inspected Luis Lara 2 times in Texas since 2025.

The latest one began on Mar 12, 2025 as a planned inspection, in Fort Worth; the case is still open.

Those inspections ended with 4 citation items: 4 serious.

Penalties were first proposed at $11,918 and still stand at $11,918.

Fall protection in construction comes up most often in these citations: 2 items under 1926.501.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,079, and Luis Lara averages $5,959 (2 cited inspections).

Luis Lara: OSHA citation items per year, 2025 to 2025
Citation items per year, by inspection date.

Want to know if OSHA cites Luis Lara again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 348101189 OPENED MAR 12, 2025Open

Planned · Partial · Safety · 4 employees at the site · Open

9464 Mint Hill Drive, Fort Worth, TX 76108 · Finish Carpentry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$3,015$3,015Mar 17, 2025Final
Citation 1, item 2
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$1,809$1,809Mar 17, 2025Final

Inspection 348029612 OPENED FEB 7, 2025Open

Unprogrammed other · Partial · Safety · 5 employees at the site · Open

8244 Coffee Springs Dr, Fort Worth, TX 76131 · Finish Carpentry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$3,547$3,547Feb 11, 2025Final
Citation 1, item 2
29 CFR 1926.1051(a) · Stairways and Ladders: general requirements
Serious$3,547$3,547Feb 11, 2025Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1051 · Stairways and Ladders: general requirements

29 CFR 1926.1051(a)

(a) A stairway or ladder shall be provided at all personnel points of access where there is a break in elevation of 19 inches (48 cm) or more, and no ramp, runway, sloped embankment, or personnel hoist is provided.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.501(b)(13)

(13) Residential construction. Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of § 1926.502.

Other finish carpentry contractors employers in Texas

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.