OSHA SearchOSHA records by employer

Luna Masonry: OSHA inspections and violations

Columbia, South Carolina · Masonry Contractors · NAICS 238140

1inspections
7citation items
$2,900current penalties
Nov 1, 2017last inspection

Luna Masonry has one OSHA inspection on record in South Carolina.

OSHA opened it on Nov 1, 2017 as a planned inspection, in Columbia.

From that inspection OSHA issued 7 citation items: 7 serious.

OSHA proposed $10,300 in penalties. After settlements and reviews the total is $2,900, down 72%.

Most often, OSHA cited 1926.451, scaffolds, general requirements (5 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Luna Masonry averages $2,900 over 1 cited inspection in that time.

Luna Masonry: OSHA citation items per year, 2017 to 2017
Citation items per year, by inspection date.

South Carolina · latest 90 days of OSHA records

43employers cited

Get notified the morning OSHA posts each new citation in South Carolina: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in South Carolina

Checking a subcontractor, a client or your own company? Watch Luna Masonry and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342788965 OPENED NOV 1, 2017Closed

Planned · Complete · Safety · 6 employees at the site · Closed Nov 5, 2018

110 Highland Center Dr, Columbia, SC 29203 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.300(b)(2) · Tools—Hand and Power: general requirements
Serious$750$375Jan 29, 2018Final
Citation 1, item 6
29 CFR 1926.451(h)(2) · Scaffolds, general requirements
Serious$750$375Jan 29, 2018Final
Citation 1, item 8a
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$1,500$1,400Jan 29, 2018Final
Citation 1, item 8b
29 CFR 1926.451(c)(1) · Scaffolds, general requirements
Serious$2,800$0Jan 29, 2018Final
Citation 1, item 8c
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$1,500$0Jan 29, 2018Final
Citation 1, item 9a
29 CFR 1926.451(f)(7) · Scaffolds, general requirements
Serious$1,500$750Jan 29, 2018Final
Citation 1, item 9b
29 CFR 1926.454(a) · Scaffold training
Serious$1,500$0Jan 29, 2018Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.300 · Tools—Hand and Power: general requirements

29 CFR 1926.300(b)(2)

(2) Belts, gears, shafts, pulleys, sprockets, spindles, drums, fly wheels, chains, or other reciprocating, rotating or moving parts of equipment shall be guarded if such parts are exposed to contact by employees or otherwise create a hazard. Guarding shall meet the requirements as set forth in American National Standards Institute, B15.1-1953 (R1958), Safety Code for Mechanical Power-Transmission Apparatus.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)

(b) Scaffold platform construction. (1) Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows:

29 CFR 1926.451(c)(1)

(c) Criteria for supported scaffolds. (1) Supported scaffolds with a height to base width (including outrigger supports, if used) ratio of more than four to one (4:1) shall be restrained from tipping by guying, tying, bracing, or equivalent means, as follows:

29 CFR 1926.454 · Scaffold training