OSHA SearchOSHA records by employer

M & C Forklift Services, Inc.: OSHA inspections and violations

Knoxville, Tennessee · Air and Gas Compressor Manufacturing · NAICS 333912

6inspections
20citation items
$14,050current penalties
Feb 7, 2024last inspection

Since 2016, OSHA inspectors have visited M & C Forklift Services, Inc. in Tennessee 6 times.

The most recent inspection opened on Feb 7, 2024 after a complaint, in Knoxville.

In all, OSHA issued 20 citation items: 14 serious, 5 repeat and 1 other-than-serious.

The proposed penalties came to $14,850; today they stand at $14,050, 5% less.

The rule cited most here is 1910.107 (spray painting and finishing), 6 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. M & C Forklift Services, Inc. averages $2,810 across 5 cited inspections.

M & C Forklift Services, Inc.: OSHA citation items per year, 2016 to 2024
Citation items per year, by inspection date.

Tennessee · latest 90 days of OSHA records

318employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in Tennessee: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Tennessee

Checking a subcontractor, a client or your own company? Watch M & C Forklift Services, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347270126 OPENED FEB 7, 2024Closed

Complaint · Partial · Health · 22 employees at the site · Closed Jul 10, 2024

601 Barbrow Lane, Knoxville, TN 37932 · Air and Gas Compressor Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.134(c)(2)(ii) · Respiratory protection
Serious$900$900Apr 22, 2024Final

Inspection 345321319 OPENED MAY 20, 2021Closed

Referral · Partial · Safety · 21 employees at the site · Closed Feb 10, 2022

601 Barbrow Lane, Knoxville, TN 37932 · Air and Gas Compressor Manufacturing · OSHA's record · Phone and website on Google Maps

Incident on Jan 25, 2021: Employee suffers fractures when caught in revolving cnc door

On January 25, 2021, an employee was working as a machinist for a firm that serviced forklifts. He was loading a piece of stock metal into a three-phase 220 Vac ATrump LV-65 dual-pallet CNC milling machine. This CNC machine was equipped with a rotary table consisting of two pallets, A and B. The pallets were separated by a metal interior door that protected employees from moving parts, flying particles, and coolant. The door had two windows with see-through material that let employees at the loading area monitor activity. The door was attached to the turntable; when the table rotated, so did the door. While the machine worked on pallet A, the operator loaded pallet B with a new workpiece. When the setup of pallet B was complete, the employee removed the setup blocks and tools from the pallet, closed the outer swivel doors, and waited for pallet A's seven-minute cycle to finish. At that point, the employee pressed a button to initiate table rotation, allowing pallet B to be machined. When the table had stopped rotating, the swivel doors were opened for removal of the finished product and to begin setup for a new workpiece. From the manufacturer, the machine did not permit table rotation if the outer swivel doors were open. The CSHO learned from employee interviews that the doors could in fact be opened moments after table rotation had begun, exposing employees to moving parts. Opening the doors in mid-rotation would not stop the table. In this incident, the employee closed the loading doors and pressed the cycle start button. To retrieve a setup block that he had left on the pallet, he opened the loading doors. The table and interior door were rotating. The employee was caught between the revolving door and the machine frame. He suffered multiple rib fractures, a fractured sternum, a degloving of his right arm, and a crushed chest and torso, with the result that both of his lungs were collapsed. On his way to the hospital, he coded several times. He was hospitalized.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.147(c)(1) · Lockout/tagout
Serious$1,200$1,200Nov 1, 2021Final
Citation 1, item 2
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$5,400$5,400Nov 1, 2021Final

Inspection 344788005 OPENED JUN 15, 2020Closed

Follow-up · Partial · Health · 23 employees at the site · Closed Jun 30, 2020

601 Barbrow Lane, Knoxville, TN 37932 · Air and Gas Compressor Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 344138466 OPENED JUL 9, 2019Closed

Complaint · Partial · Health · 24 employees at the site · Closed Nov 21, 2019

601 Barbrow Lane, Knoxville, TN 37932 · Air and Gas Compressor Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.107(b)(5)(i) · Spray painting and finishing
Serious$1,400$1,000Sep 27, 2019Final
Citation 1, item 2
29 CFR 1910.252(b)(2)(iii) · Welding fire safety
Serious$1,400$1,000Sep 27, 2019Final
Citation 2, item 1
29 CFR 1910.1200(h)(1) · Hazard communication
Repeat$200$200Sep 27, 2019Final
Citation 3, item 1
29 CFR TDLWD RULE 800-01-09-.07
Other-than-serious$200$200Sep 27, 2019Final

Inspection 344160023 OPENED JUL 9, 2019Closed

Complaint · Partial · Safety · 24 employees at the site · Closed Oct 31, 2019

601 Barbrow Lane, Knoxville, TN 37932 · Air and Gas Compressor Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.243(c)(3) · Guarding of portable powered tools
Serious$750$750Sep 20, 2019Final

Inspection 341956878 OPENED DEC 2, 2016Closed

Complaint · Partial · Health · 20 employees at the site · Closed May 11, 2017

601 Barbrow Lane, Knoxville, TN 37932 · All Other Miscellaneous General Purpose Machinery Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.107(b)(9) · Spray painting and finishing
Serious$1,400$1,400Apr 19, 2017Final
Citation 1, item 1b
29 CFR 1910.107(b)(10) · Spray painting and finishing
Serious$0$0Apr 19, 2017Final
Citation 1, item 1c
29 CFR 1910.107(i)(4) · Spray painting and finishing
Serious$0$0Apr 19, 2017Final
Citation 1, item 1d
29 CFR 1910.107(i)(8) · Spray painting and finishing
Serious$0$0Apr 19, 2017Final
Citation 1, item 1e
29 CFR 1910.107(c)(6) · Spray painting and finishing
Serious$0$0Apr 19, 2017Final
Citation 1, item 2a
29 CFR 1910.134(c)(1) · Respiratory protection
Serious$1,400$1,400Apr 19, 2017Final
Citation 1, item 2b
29 CFR 1910.134(c)(2)(ii) · Respiratory protection
Serious$0$0Apr 19, 2017Final
Citation 1, item 2c
29 CFR 1910.134(e)(1) · Respiratory protection
Serious$0$0Apr 19, 2017Final
Citation 2, item 1
29 CFR 1910.134(c)(2)(i) · Respiratory protection
Repeat$200$200Apr 19, 2017Final
Citation 2, item 2a
29 CFR 1910.1200(e)(1) · Hazard communication
Repeat$400$400Apr 19, 2017Final
Citation 2, item 2b
29 CFR 1910.1200(g)(1) · Hazard communication
Repeat$0$0Apr 19, 2017Final
Citation 2, item 2c
29 CFR 1910.1200(h)(1) · Hazard communication
Repeat$0$0Apr 19, 2017Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.107(b)(10)

(10) Illumination. When spraying areas are illuminated through glass panels or other transparent materials, only fixed lighting units shall be used as a source of illumination. Panels shall effectively isolate the spraying area from the area in which the lighting unit is located, and shall be of a noncombustible material of such a nature or so protected that breakage will be unlikely. Panels shall be so arranged that normal accumulations of residue on the exposed surface of the panel will not be raised to a dangerous temperature by radiation or conduction from the source of illumination.

29 CFR 1910.107(b)(5)(i)

(i) The spraying operations except electrostatic spraying operations shall be so designed, installed and maintained that the average air velocity over the open face of the booth (or booth cross section during spraying operations) shall be not less than 100 linear feet per minute. Electrostatic spraying operations may be conducted with an air velocity over the open face of the booth of not less than 60 linear feet per minute, or more, depending on the volume of the finishing material being applied and its flammability and explosion characteristics. Visible gauges or audible alarm or pressure activated devices shall be installed to indicate or insure that the required air velocity is maintained. Filter rolls shall be inspected to insure proper replacement of filter media.

29 CFR 1910.107(b)(9)

(9) Cleaning. Spray booths shall be so installed that all portions are readily accessible for cleaning. A clear space of not less than 3 feet on all sides shall be kept free from storage or combustible construction.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.212 · Machine guarding

29 CFR 1910.243 · Guarding of portable powered tools

29 CFR 1910.252 · Welding fire safety

Other air and gas compressor manufacturing employers in Tennessee

Alert subscribers get notified of each newly cited employer in Tennessee the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.