Inspection 348133935 OPENED MAR 25, 2025Closed
3010 E Sd-44, Rapid City, SD 57703 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Rapid City, South Dakota · Commercial and Institutional Building Construction · NAICS 236220
Since 1983, OSHA inspectors have visited Mac Construction Company, Inc. in South Dakota 7 times.
The most recent inspection opened on Mar 25, 2025, in Rapid City.
In all, OSHA issued 19 citation items: 14 serious and 5 other-than-serious.
The proposed penalties came to $9,204; today they stand at $8,064, 12% less.
The rule cited most here is 1926.304 (woodworking tools), 4 times.
Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Mac Construction Company, Inc. averages $5,304 across 1 cited inspection.
Mac Construction Company, Inc. also files yearly injury logs with OSHA, summarized below.
South Dakota · latest 90 days of OSHA records
30employers cited
Get notified the morning OSHA posts each new citation in South Dakota: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in South Dakota
Checking a subcontractor, a client or your own company? Watch Mac Construction Company, Inc. and get notified the morning OSHA posts a new citation for it.
Watch this company3010 E Sd-44, Rapid City, SD 57703 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
2300 Elgin Street, Rapid City, SD 57703 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1926.451(e)(8) · Scaffolds, general requirements |
Other-than-serious | $2,273 | $2,273 | Jun 26, 2019 | Final |
| Citation 1, item 1b 29 CFR 1926.451(e)(6)(vi) · Scaffolds, general requirements |
Other-than-serious | $0 | $0 | Jun 26, 2019 | Final |
| Citation 1, item 2 29 CFR 1926.501(b)(1) · Fall protection in construction |
Other-than-serious | $3,031 | $3,031 | Jun 26, 2019 | Final |
255 Texas Street, Rapid City, SD 57701 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1926.453(b)(2)(v) · Aerial lifts |
Serious | $2,975 | $2,082 | Oct 18, 2011 | Final |
| Citation 1, item 1b 29 CFR 1926.501(b)(11) · Fall protection in construction |
Serious | $0 | $0 | Oct 18, 2011 | Final |
2834 Jackson Boulevard, Rapid City, SD 57702 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Deadwood Railroad Depot, Deadwood, SD 57732 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1926.304(f) · Woodworking tools |
Serious | $225 | $158 | Dec 19, 1991 | Closed |
| Citation 1, item 1b 29 CFR 1926.304(f) · Woodworking tools |
Serious | $0 | $0 | Dec 19, 1991 | Closed |
| Citation 1, item 1c 29 CFR 1926.304(f) · Woodworking tools |
Serious | $0 | $0 | Dec 19, 1991 | Closed |
| Citation 1, item 1d 29 CFR 1926.304(f) · Woodworking tools |
Serious | $0 | $0 | Dec 19, 1991 | Closed |
| Citation 1, item 2a 29 CFR 1926.403(a) · Electrical equipment on job sites |
Serious | $300 | $210 | Dec 19, 1991 | Closed |
| Citation 1, item 2b 29 CFR 1926.403(b)(1) · Electrical equipment on job sites |
Serious | $0 | $0 | Dec 19, 1991 | Closed |
| Citation 1, item 2c 29 CFR 1926.404(b)(1)(i) · Ground-fault protection on job sites |
Serious | $0 | $0 | Dec 19, 1991 | Closed |
| Citation 1, item 2d 29 CFR 1926.405(b)(1) · Job-site wiring |
Serious | $0 | $0 | Dec 19, 1991 | Closed |
| Citation 1, item 3 29 CFR 1926.500(d)(1) · Scope, application, and definitions applicable to this subpart |
Serious | $300 | $210 | Dec 19, 1991 | Closed |
Lawrence County Courthouse, Deadwood, SD 57732 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
West St Cloud & Cayon Lake Rd, Rapid City, SD 57701 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1926.400(a) · Introduction |
Serious | $100 | $100 | May 12, 1983 | Closed |
| Citation 1, item 1b 29 CFR 1926.400(h)(2) · Introduction |
Serious | $0 | $0 | May 12, 1983 | Closed |
| Citation 1, item 1c 29 CFR 1926.401(a)(1) · [Reserved] |
Serious | $0 | $0 | May 12, 1983 | Closed |
| Citation 2, item 1 29 CFR 1926.350(a)(9) · Gas welding and cutting |
Other-than-serious | $0 | $0 | May 12, 1983 | Closed |
| Citation 2, item 2 29 CFR 1926.602(c)(1) · Earthmovers and forklifts in construction |
Other-than-serious | $0 | $0 | May 12, 1983 | Closed |
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2025, the Rapid City site logged 3 recordable injuries or illnesses among about 41 workers: 7.5 per 100 full-time workers, against a median of 0.6 for its industry.
| Site and year | Workers | Cases | Days-away cases | Rate | Industry median |
|---|---|---|---|---|---|
| MAC Construction Co., Inc. Rapid City · 2025 | 41 | 3 | 0 | 7.5 | 0.6 |
Included with any plan: 8 more yearly logs from these sites, back to 2017, with each site's average rate over its latest three years. Already a subscriber? Sign in.
See plansCurrent text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1926.304(f)
(f) Other requirements. All woodworking tools and machinery shall meet other applicable requirements of American National Standards Institute, 01.1-1961, Safety Code for Woodworking Machinery.
29 CFR 1926.350(a)(9)
(9) Compressed gas cylinders shall be secured in an upright position at all times except, if necessary, for short periods of time while cylinders are actually being hoisted or carried.
29 CFR 1926.400(a)
(a) Installation safety requirements. Installation safety requirements are contained in §§ 1926.402 through 1926.408. Included in this category are electric equipment and installations used to provide electric power and light on jobsites.
Alert subscribers get notified of each newly cited employer in South Dakota the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.