OSHA SearchOSHA records by employer

Manual de Jesus Gaytan: OSHA inspections and violations

Benbrook, Texas · Finish Carpentry Contractors · NAICS 238350

1inspections
3citation items
$3,838current penalties
Nov 6, 2024last inspection

OSHA has inspected Manual de Jesus Gaytan once in Texas.

The inspection began on Nov 6, 2024 as a planned inspection, in Benbrook; the case is still open.

That inspection ended with 3 citation items: 3 serious.

Penalties were first proposed at $6,396 and now stand at $3,838, 40% lower after settlements or reviews.

Scaffolds, general requirements comes up most often in these citations: 2 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Manual de Jesus Gaytan averages $3,838 (1 cited inspection).

Manual de Jesus Gaytan: OSHA citation items per year, 2024 to 2024
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

405employers cited

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch Manual de Jesus Gaytan and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347863474 OPENED NOV 6, 2024Open

Planned · Partial · Safety · 2 employees at the site · Open

10501 Norah Bend Trail, Benbrook, TX 76126 · Finish Carpentry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$2,939$1,763Nov 26, 2024Final
Citation 1, item 2a
29 CFR 1926.451(b)(2) · Scaffolds, general requirements
Serious$3,457$2,074Nov 26, 2024Final
Citation 1, item 2b
29 CFR 1926.452(a)(4) · Rules for each type of scaffold
Serious$0$0Nov 26, 2024Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(2)

(2) Except as provided in paragraphs (b)(2)(i) and (b)(2)(ii) of this section, each scaffold platform and walkway shall be at least 18 inches (46 cm) wide.

29 CFR 1926.451(g)(1)(vii)

(vii) For all scaffolds not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, each employee shall be protected by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section.

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.452(a)(4)

(4) Diagonal bracing in both directions shall be installed across the entire outside face of all double- and single-pole scaffolds.