OSHA SearchOSHA records by employer

Marine Technology Inc: OSHA inspections and violations

Oconto, Wisconsin · Boat Building · NAICS 336612

5inspections
34citation items
$101,624current penalties
Apr 29, 2024last inspection

Since 2012, OSHA inspectors have visited Marine Technology Inc in Wisconsin 5 times.

The most recent inspection opened on Apr 29, 2024 after a complaint, in Oconto.

In all, OSHA issued 34 citation items: 27 serious, 6 repeat and 1 other-than-serious.

The proposed penalties came to $267,597; today they stand at $101,624, 62% less.

The rule cited most here is 1910.134 (respiratory protection), 7 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. Marine Technology Inc averages $24,990 across 4 cited inspections.

Marine Technology Inc also files yearly injury logs with OSHA, summarized below.

It reported 1 severe injury to OSHA since 2015.

Marine Technology Inc: OSHA citation items per year, 2012 to 2024
Citation items per year, by inspection date.

Wisconsin · latest 90 days of OSHA records

229employers cited

Get notified the morning OSHA posts each new citation in Wisconsin: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Wisconsin

Checking a subcontractor, a client or your own company? Watch Marine Technology Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347446262 OPENED APR 29, 2024Closed

Complaint · Partial · Health · 84 employees at the site · Closed May 29, 2026

206 Charles Street, Oconto, WI 54153 · Boat Building · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.28(b)(15) · Fall protection in general industry
Serious$13,690$6,845Aug 23, 2024Final
Citation 1, item 2
29 CFR 1910.94(c)(2) · Ventilation
Serious$11,409$5,704Aug 23, 2024Final
Citation 1, item 3a
29 CFR 1910.106(e)(2)(ii)(b)(2) · Flammable liquids
Serious$11,409$5,704Aug 23, 2024Final
Citation 1, item 3b
29 CFR 1910.106(e)(6)(ii) · Flammable liquids
Serious$0$0Aug 23, 2024Final

Inspection 347446528 OPENED APR 29, 2024Closed

Complaint · Partial · Safety · 83 employees at the site · Closed May 29, 2026

206 Charles Street, Oconto, WI 54153 · Boat Building · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.178(a)(4) · Forklifts and other powered industrial trucks
Repeat$18,252$9,126Aug 23, 2024Final
Citation 1, item 1b
29 CFR 1910.178(a)(5) · Forklifts and other powered industrial trucks
Repeat$0$0Aug 23, 2024Final
Citation 2, item 1
29 CFR 1910.22(a)(3) · Walking-working surfaces
Other-than-serious$0$0Aug 23, 2024Final

Inspection 347463820 OPENED APR 29, 2024Closed

Follow-up · Partial · Health · 83 employees at the site · Closed May 29, 2026

206 Charles Street, Oconto, WI 54153 · Boat Building · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.134(g)(1)(i) · Respiratory protection
Serious$11,409$5,704Aug 23, 2024Final
Citation 2, item 1a
29 CFR 1910.106(e)(2)(iv)(a) · Flammable liquids
Repeat$31,939$15,969Aug 23, 2024Final
Citation 2, item 1b
29 CFR 1910.1200(f)(6)(ii) · Hazard communication
Repeat$31,939$0Aug 23, 2024Final
Citation 2, item 2a
29 CFR 1910.1000(a)(2) · Air contaminants
Repeat$22,818$11,409Aug 23, 2024Final
Citation 2, item 2b
29 CFR 1910.1000(e) · Air contaminants
Repeat$0$0Aug 23, 2024Final

Inspection 345125967 OPENED FEB 3, 2021Closed

Monitoring · Partial · Health · 55 employees at the site · Closed Jul 10, 2023

206 Charles Street, Oconto, WI 54153 · Boat Building · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.28(b)(11)(ii) · Fall protection in general industry
Serious$7,022$3,509Jun 10, 2021Final
Citation 1, item 2
29 CFR 1910.106(e)(2)(iv)(a) · Flammable liquids
Serious$8,778$4,389Jun 10, 2021Final
Citation 1, item 3a
29 CFR 1910.134(a)(2) · Respiratory protection
Serious$8,778$4,389Jun 10, 2021Final
Citation 1, item 3b
29 CFR 1910.1000(a)(2) · Air contaminants
Serious$0$0Jun 10, 2021Final
Citation 1, item 3c
29 CFR 1910.1000(e) · Air contaminants
Serious$0$0Jun 10, 2021Final
Citation 1, item 4a
29 CFR 1910.134(c)(1) · Respiratory protection
Serious$10,533$5,266Jun 10, 2021Final
Citation 1, item 4b
29 CFR 1910.134(c)(2)(ii) · Respiratory protection
Serious$0$0Jun 10, 2021Final
Citation 1, item 4c
29 CFR 1910.134(e)(1) · Respiratory protection
Serious$0$0Jun 10, 2021Final
Citation 1, item 4d
29 CFR 1910.134(f)(1) · Respiratory protection
Serious$0$0Jun 10, 2021Final
Citation 1, item 4e
29 CFR 1910.134(k) · Respiratory protection
Serious$0$0Jun 10, 2021Final
Citation 1, item 5a
29 CFR 1910.178(a)(4) · Forklifts and other powered industrial trucks
Serious$8,778$4,389Jun 10, 2021Final
Citation 1, item 5b
29 CFR 1910.178(a)(5) · Forklifts and other powered industrial trucks
Serious$0$0Jun 10, 2021Final
Citation 1, item 5c
29 CFR 1910.178(l)(6) · Forklifts and other powered industrial trucks
Serious$8,778$0Jun 10, 2021Final
Citation 1, item 7a
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Serious$10,533$5,266Jun 10, 2021Final
Citation 1, item 7b
29 CFR 1910.305(g)(1)(iv)(c) · Electrical wiring methods
Serious$0$0Jun 10, 2021Final
Citation 1, item 7c
29 CFR 1910.334(a)(2)(ii) · Using electrical equipment
Serious$0$0Jun 10, 2021Final
Citation 1, item 8a
29 CFR 1910.1200(e)(1) · Hazard communication
Serious$12,288$12,288Jun 10, 2021Final
Citation 1, item 8b
29 CFR 1910.1200(f)(6)(ii) · Hazard communication
Serious$12,288$0Jun 10, 2021Final
Citation 1, item 8c
29 CFR 1910.1200(g)(1) · Hazard communication
Serious$12,288$0Jun 10, 2021Final
Citation 1, item 8d
29 CFR 1910.1200(h)(1) · Hazard communication
Serious$12,288$0Jun 10, 2021Final

Inspection 332795954 OPENED MAR 8, 2012Closed

Complaint · Partial · Safety · 9 employees at the site · Closed Mar 29, 2012

2984 Holmgren Way, Green Bay, WI 54304 · Boat Building · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.334(a)(2)(ii) · Using electrical equipment
Serious$2,380$1,666Mar 16, 2012Final
Citation 1, item 1b
29 CFR 1910.334(a)(3)(ii) · Using electrical equipment
Serious$0$0Mar 16, 2012Final

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2023, the Oconto site logged 10 recordable injuries or illnesses among about 85 workers: 8.9 per 100 full-time workers, against a median of 3.8 for its industry. Those cases cost 30 days away from work.

Site and yearWorkersCasesDays-away casesRateIndustry median
Marine Technology Inc
Oconto · 2023
85 1028.93.8

Included with any plan: 1 more yearly log from these sites, back to 2022, with each site's average rate over its latest three years. Already a subscriber? Sign in.

See plans

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 1 report on file.

Jun 1, 2020, Oconto: Amputation · amputations · finger(s), fingernail(s), n.e.c.

An employee was using a table saw to cut thin foam material when his glove was pulled into the blade and his right index finger was amputated.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1000 · Air contaminants

29 CFR 1910.1000(a)(2)

(2) Other substances—8-hour Time Weighted Averages. An employee's exposure to any substance in Table Z-1, the exposure limit of which is not preceded by a “C”, shall not exceed the 8-hour Time Weighted Average given for that substance in any 8-hour work shift of a 40-hour work week.

29 CFR 1910.1000(e)

(e) To achieve compliance with paragraphs (a) through (d) of this section, administrative or engineering controls must first be determined and implemented whenever feasible. When such controls are not feasible to achieve full compliance, protective equipment or any other protective measures shall be used to keep the exposure of employees to air contaminants within the limits prescribed in this section. Any equipment and/or technical measures used for this purpose must be approved for each particular use by a competent industrial hygienist or other technically qualified person. Whenever respirators are used, their use shall comply with 1910.134.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(e)(2)(ii)(b)(2)

(ii) Containers. Flammable liquids shall be stored in tanks or closed containers.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.22 · Walking-working surfaces

29 CFR 1910.28 · Fall protection in general industry

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.334 · Using electrical equipment

29 CFR 1910.94 · Ventilation

Other boat building employers in Wisconsin

Alert subscribers get notified of each newly cited employer in Wisconsin the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.