Inspection 345532519 OPENED SEP 16, 2021Closed
4 Louise Drive, Ivyland, PA 18974 · Fabricated Structural Metal Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Ivyland, Pennsylvania · Fabricated Structural Metal Manufacturing · NAICS 332312
Martellis Metal Fabrication Inc has 4 OSHA inspections on record in Pennsylvania, the first in 2014.
OSHA's last visit started on Sep 16, 2021 after a complaint, in Ivyland.
Across those inspections OSHA issued 12 citation items: 12 serious.
OSHA proposed $14,000 in penalties. After settlements and reviews the total is $7,700, down 45%.
Most often, OSHA cited 1910.134, respiratory protection (4 items).
For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $3,600. Martellis Metal Fabrication Inc averages $2,100 over 1 cited inspection in that time.
Pennsylvania · latest 90 days of OSHA records
280employers cited
2 of them in the same industry
Get notified the morning OSHA posts each new citation in Pennsylvania: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Pennsylvania
Checking a subcontractor, a client or your own company? Watch Martellis Metal Fabrication Inc and get notified the morning OSHA posts a new citation for it.
Watch this company4 Louise Drive, Ivyland, PA 18974 · Fabricated Structural Metal Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
4 Louise Drive, Ivyland, PA 18974 · Other Building Finishing Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
4 Louise Drive, Ivyland, PA 18974 · Fabricated Structural Metal Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.107(c)(6) · Spray painting and finishing |
Serious | $2,800 | $2,100 | Apr 16, 2015 | Final |
4 Louise Drive, Ivyland, PA 18974 · Fabricated Structural Metal Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1910.107(b)(5)(i) · Spray painting and finishing |
Serious | $2,100 | $1,050 | Mar 6, 2015 | Final |
| Citation 1, item 1b 29 CFR 1910.107(d)(3) · Spray painting and finishing |
Serious | $0 | $0 | Mar 6, 2015 | Final |
| Citation 1, item 1c 29 CFR 1910.107(e)(2) · Spray painting and finishing |
Serious | $0 | $0 | Mar 6, 2015 | Final |
| Citation 1, item 2a 29 CFR 1910.134(c)(2)(ii) · Respiratory protection |
Serious | $2,100 | $1,050 | Mar 6, 2015 | Final |
| Citation 1, item 2b 29 CFR 1910.134(k)(6) · Respiratory protection |
Serious | $0 | $0 | Mar 6, 2015 | Final |
| Citation 1, item 3a 29 CFR 1910.134(i)(7) · Respiratory protection |
Serious | $2,800 | $1,400 | Mar 6, 2015 | Final |
| Citation 1, item 3b 29 CFR 1910.134(i)(5)(iv) · Respiratory protection |
Serious | $0 | $0 | Mar 6, 2015 | Final |
| Citation 1, item 4 29 CFR 1910.157(g)(1) · Portable fire extinguishers |
Serious | $2,100 | $1,050 | Mar 6, 2015 | Final |
| Citation 1, item 5a 29 CFR 1910.1200(e)(1) · Hazard communication |
Serious | $2,100 | $1,050 | Mar 6, 2015 | Final |
| Citation 1, item 5b 29 CFR 1910.1200(g)(8) · Hazard communication |
Serious | $0 | $0 | Mar 6, 2015 | Final |
| Citation 1, item 5c 29 CFR 1910.1200(h)(1) · Hazard communication |
Serious | $0 | $0 | Mar 6, 2015 | Final |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.107(b)(5)(i)
(i) The spraying operations except electrostatic spraying operations shall be so designed, installed and maintained that the average air velocity over the open face of the booth (or booth cross section during spraying operations) shall be not less than 100 linear feet per minute. Electrostatic spraying operations may be conducted with an air velocity over the open face of the booth of not less than 60 linear feet per minute, or more, depending on the volume of the finishing material being applied and its flammability and explosion characteristics. Visible gauges or audible alarm or pressure activated devices shall be installed to indicate or insure that the required air velocity is maintained. Filter rolls shall be inspected to insure proper replacement of filter media.
29 CFR 1910.107(c)(6)
(6) Wiring type approved. Electrical wiring and equipment not subject to deposits of combustible residues but located in a spraying area as herein defined shall be of explosion-proof type approved for Class I, group D locations and shall otherwise conform to the provisions of subpart S of this part, for Class I, Division 1, Hazardous Locations. Electrical wiring, motors, and other equipment outside of but within twenty (20) feet of any spraying area, and not separated therefrom by partitions, shall not produce sparks under normal operating conditions and shall otherwise conform to the provisions of subpart S of this part for Class I, Division 2 Hazardous Locations.
29 CFR 1910.107(d)(3)
(3) Independent exhaust. Each spray booth shall have an independent exhaust duct system discharging to the exterior of the building, except that multiple cabinet spray booths in which identical spray finishing material is used with a combined frontal area of not more than 18 square feet may have a common exhaust. If more than one fan serves one booth, all fans shall be so interconnected that one fan cannot operate without all fans being operated.
Alert subscribers get notified of each newly cited employer in Pennsylvania the morning it is posted. See the alert plans.