OSHA SearchOSHA records by employer

Martin Masonry LLC: OSHA inspections and violations

Walker, Louisiana · Masonry Contractors · NAICS 238140

2inspections
7citation items
$3,911current penalties
Oct 3, 2016last inspection

Since 1982, OSHA inspectors have visited Martin Masonry LLC in Louisiana 2 times.

The most recent inspection opened on Oct 3, 2016 as a planned inspection, in Vidalia.

In all, OSHA issued 7 citation items: 3 serious and 4 other-than-serious.

The proposed penalties came to $6,519; today they stand at $3,911, 40% less.

The rule cited most here is 1926.451 (scaffolds, general requirements), 4 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Martin Masonry LLC averages $3,911 across 1 cited inspection.

Martin Masonry LLC: OSHA citation items per year, 1982 to 2016
Citation items per year, by inspection date.

Louisiana · latest 90 days of OSHA records

18employers cited

Get notified the morning OSHA posts each new citation in Louisiana: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Louisiana

Checking a subcontractor, a client or your own company? Watch Martin Masonry LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341829919 OPENED OCT 3, 2016Closed

Planned · Partial · Safety · 4 employees at the site · Closed Oct 10, 2018

101 Spruce Street, Vidalia, LA 71373 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$2,173$1,304Jan 17, 2017Final
Citation 1, item 2
29 CFR 1926.451(c)(2)(ii) · Scaffolds, general requirements
Serious$2,173$1,304Jan 17, 2017Final
Citation 1, item 3
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$2,173$1,303Jan 17, 2017Final

Inspection 16167132 OPENED MAR 18, 1982Closed

Planned · Complete · Safety · 10 employees at the site · Closed Oct 8, 1982

Levi Milton Elem School, Walker, LA 70785 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1903.2(a)(1) · Posting of notice; availability of the Act, regulations and applicable standards
Other-than-serious$0$0Mar 25, 1982Closed
Citation 1, item 2
29 CFR 1904.2(a) · Partial exemption for establishments in certain industries
Other-than-serious$0$0Mar 25, 1982Closed
Citation 1, item 3
29 CFR 1926.102(a)(1) · Eye and face protection in construction
Other-than-serious$0$0Mar 25, 1982Closed
Citation 1, item 4
29 CFR 1926.451(a)(4) · Scaffolds, general requirements
Other-than-serious$0$0Mar 25, 1982Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1903.2 · Posting of notice; availability of the Act, regulations and applicable standards

29 CFR 1903.2(a)(1)

(a)(1) Each employer shall post and keep posted a notice or notices, to be furnished by the Occupational Safety and Health Administration, U.S. Department of Labor, informing employees of the protections and obligations provided for in the Act, and that for assistance and information, including copies of the Act and of specific safety and health standards, employees should contact the employer or the nearest office of the Department of Labor. Such notice or notices shall be posted by the employer in each establishment in a conspicuous place or places where notices to employees are customarily posted. Each employer shall take steps to insure that such notices are not altered, defaced, or covered by other material.

29 CFR 1904.2 · Partial exemption for establishments in certain industries

29 CFR 1926.102 · Eye and face protection in construction

29 CFR 1926.102(a)(1)

(a) General. (1) The employer shall ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(a)(4)

(4) Each suspension rope, including connecting hardware, used on adjustable suspension scaffolds shall be capable of supporting, without failure, at least 6 times the maximum intended load applied or transmitted to that rope with the scaffold operating at either the rated load of the hoist, or 2 (minimum) times the stall load of the hoist, whichever is greater.

Other masonry contractors employers in Louisiana

Alert subscribers get notified of each newly cited employer in Louisiana the morning it is posted. See the alert plans.