OSHA SearchOSHA records by employer

Martin Roofing LLC: OSHA inspections and violations

Wichita Falls, Texas · Roofing Contractors · NAICS 238160

3inspections
6citation items
$4,200current penalties
Feb 25, 2026last inspection

Since 1985, OSHA inspectors have visited Martin Roofing LLC in Texas 3 times.

The most recent inspection opened on Feb 25, 2026 as a planned inspection, in Plano and is still open.

In all, OSHA issued 6 citation items: 3 serious and 3 other-than-serious.

The proposed penalties came to $8,144; today they stand at $4,200, 48% less.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Martin Roofing LLC averages $4,000 across 1 cited inspection.

Martin Roofing LLC: OSHA citation items per year, 1985 to 2026
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

393employers cited

48 of them in the same industry

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch Martin Roofing LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348774001 OPENED FEB 25, 2026Open

Planned · Partial · Safety · 6 employees at the site · Open

1250 Industrial Blvd, Plano, TX 75023 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(10) · Fall protection in construction
Serious$3,972$2,000Jul 2, 2026Final
Citation 1, item 2
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$3,972$2,000Jul 2, 2026Final

Inspection 100276203 OPENED APR 7, 1986Closed

Planned · No inspection · Safety · Closed Apr 8, 1986

1745 W Irving Blvd, Irving, TX 75061 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 101816890 OPENED DEC 23, 1985Closed

Referral · Complete · Safety · 4 employees at the site · Closed Mar 30, 1988

1400 11th Street, Wichita Falls, TX 76301 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.500(g)(1) · Scope, application, and definitions applicable to this subpart
Serious$200$200Jan 13, 1986Closed
Citation 2, item 1
29 CFR 1903.2(a)(1) · Posting of notice; availability of the Act, regulations and applicable standards
Other-than-serious$0$0Jan 13, 1986Closed
Citation 2, item 2
29 CFR 1926.25(a) · Housekeeping
Other-than-serious$0$0Jan 13, 1986Closed
Citation 2, item 3
29 CFR 1926.152(a)(1) · Flammable liquids
Other-than-serious$0$0Jan 13, 1986Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1903.2 · Posting of notice; availability of the Act, regulations and applicable standards

29 CFR 1903.2(a)(1)

(a)(1) Each employer shall post and keep posted a notice or notices, to be furnished by the Occupational Safety and Health Administration, U.S. Department of Labor, informing employees of the protections and obligations provided for in the Act, and that for assistance and information, including copies of the Act and of specific safety and health standards, employees should contact the employer or the nearest office of the Department of Labor. Such notice or notices shall be posted by the employer in each establishment in a conspicuous place or places where notices to employees are customarily posted. Each employer shall take steps to insure that such notices are not altered, defaced, or covered by other material.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.152 · Flammable liquids

29 CFR 1926.152(a)(1)

(a) General requirements. (1) Only approved containers and portable tanks shall be used for storage and handling of flammable liquids. Approved safety cans or Department of Transportation approved containers shall be used for the handling and use of flammable liquids in quantities of 5 gallons or less, except that this shall not apply to those flammable liquid materials which are highly viscid (extremely hard to pour), which may be used and handled in original shipping containers. For quantities of one gallon or less, the original container may be used, for storage, use and handling of flammable liquids.

29 CFR 1926.25 · Housekeeping

29 CFR 1926.500 · Scope, application, and definitions applicable to this subpart

29 CFR 1926.501 · Fall protection in construction