OSHA SearchOSHA records by employer

Martinez Construction Ltd.: OSHA inspections and violations

Longmont, Colorado · Framing Contractors · NAICS 238130

14inspections
33citation items
$31,055current penalties
Aug 6, 2025last inspection

Martinez Construction Ltd. has 14 OSHA inspections on record in Colorado, the first in 1997.

OSHA's last visit started on Aug 6, 2025 as a planned inspection, in Westminster.

Across those inspections OSHA issued 33 citation items: 31 serious and 2 other-than-serious.

OSHA proposed $41,609 in penalties. After settlements and reviews the total is $31,055, down 25%.

Most often, OSHA cited 1926.451, scaffolds, general requirements (11 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Martinez Construction Ltd. averages $4,392 over 3 cited inspections in that time.

Martinez Construction Ltd.: OSHA citation items per year, 1997 to 2025
Citation items per year, by inspection date.

Colorado · latest 90 days of OSHA records

136employers cited

24 of them in the same industry

Get notified the morning OSHA posts each new citation in Colorado: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Colorado

Checking a subcontractor, a client or your own company? Watch Martinez Construction Ltd. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348418005 OPENED AUG 6, 2025Closed

Planned · Partial · Safety · 8 employees at the site · Closed Mar 26, 2026

8670 Clay St, Westminster, CO 80031 · Siding Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$3,547$2,128Jan 15, 2026Final

Inspection 346146608 OPENED AUG 12, 2022Closed

Complaint · Partial · Safety · 3 employees at the site · Closed May 8, 2023

2655 63rd Street, Boulder, CO 80301 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$4,688$2,344Feb 6, 2023Final
Citation 1, item 2
29 CFR 1926.503(a)(1) · Fall protection training in construction
Other-than-serious$4,688$2,344Feb 6, 2023Final

Inspection 344732003 OPENED APR 23, 2020Closed

Complaint · Partial · Safety · 5 employees at the site · Closed Sep 18, 2023

4318 E. Utah Place, Denver, CO 80222 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$2,313$2,313Aug 19, 2020Final
Citation 1, item 1b
29 CFR 1926.503(a)(1) · Fall protection training in construction
Serious$0$0Aug 19, 2020Final
Citation 1, item 2
29 CFR 1926.416(a)(1) · Electrical safety in construction
Serious$2,313$2,313Aug 19, 2020Final
Citation 1, item 3a
29 CFR 1926.102(a)(1) · Eye and face protection in construction
Serious$1,735$1,735Aug 19, 2020Final
Citation 1, item 3b
29 CFR 1910.135(a)(1) · Head protection
Serious$0$0Aug 19, 2020Final

Inspection 339490740 OPENED NOV 15, 2013Closed

Follow-up · No inspection · Safety · 3 employees at the site · Closed Nov 20, 2013

1656 Venice Lane, Longmont, CO 80503 · Framing Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 339297251 OPENED AUG 15, 2013Closed

Follow-up · No inspection · Safety · 3 employees at the site · Closed Aug 15, 2013

250 Ricker Ln., Johnstown, CO 80534 · Other Foundation, Structure, and Building Exterior Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 339315871 OPENED AUG 10, 2013Closed

Planned · Partial · Safety · 3 employees at the site · Closed Jul 12, 2016

1656 Venice Lane, Longmont, CO 80503 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$1,200$1,200Sep 30, 2013Final

Inspection 339183667 OPENED JUL 13, 2013Closed

Planned · Partial · Safety · 3 employees at the site · Closed Jan 27, 2016

250 Ricker Ln., Johnstown, CO 80534 · Siding Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$1,700$1,700Jul 22, 2013Final

Inspection 330987447 OPENED SEP 10, 2011Closed

Planned · Partial · Safety · 4 employees at the site · Closed Aug 2, 2016

1520 Warren, Lakewood, CO 80123 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.304(d) · Woodworking tools
Serious$2,400$2,400Mar 2, 2012Final
Citation 1, item 2
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$4,200$4,200Mar 2, 2012Final
6 older inspections

Inspection 313417412 OPENED MAR 6, 2010Closed

Planned · Partial · Safety · 4 employees at the site · Closed Apr 13, 2010

1113 Petras St., Erie, CO 80516 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.102(a)(1) · Eye and face protection in construction
Serious$300$210Mar 17, 2010Closed
Citation 1, item 2
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$525$368Mar 17, 2010Closed

Inspection 313716102 OPENED DEC 15, 2009Closed

Complaint · Partial · Safety · 10 employees at the site · Closed Jul 5, 2012

900 S. Kipling St., Lakewood, CO 80232 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.100(a) · Hard hats in construction
Serious$300$300Jan 7, 2010Closed
Citation 1, item 2
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$1,500$1,500Jan 7, 2010Closed
Citation 1, item 3
29 CFR 1926.1053(b)(4) · Ladders in construction
Serious$300$300Jan 7, 2010Closed

Inspection 307524629 OPENED AUG 26, 2004Closed

Planned · Partial · Safety · 4 employees at the site · Closed Oct 7, 2004

2202 E. 14th Ave., Denver, CO 80237 · Residential Remodelers · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(c)(3) · Scaffolds, general requirements
Serious$600$300Sep 9, 2004Closed
Citation 1, item 2a
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$1,500$750Sep 9, 2004Closed
Citation 1, item 2b
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$0$0Sep 9, 2004Closed
Citation 1, item 3
29 CFR 1926.454(a) · Scaffold training
Serious$1,500$750Sep 9, 2004Closed
Citation 2, item 1
29 CFR 1926.20(b)(1) · Construction safety programs
Other-than-serious$0$0Sep 9, 2004Closed

Inspection 306370099 OPENED JUN 2, 2003Closed

Follow-up · No inspection · Safety · Closed Jun 2, 2003

8615 Portico, Longmont, CO 80501 · Framing Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 304985286 OPENED FEB 13, 2003Closed

Unprogrammed other · Partial · Safety · 4 employees at the site · Closed Feb 21, 2007

8615 Portico, Longmont, CO 80501 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$1,500$900Feb 19, 2003Closed
Citation 1, item 1b
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$0$0Feb 19, 2003Closed
Citation 1, item 2a
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Serious$1,500$900Feb 19, 2003Closed
Citation 1, item 2b
29 CFR 1926.451(c)(3) · Scaffolds, general requirements
Serious$0$0Feb 19, 2003Closed
Citation 1, item 2c
29 CFR 1926.452(c)(2) · Rules for each type of scaffold
Serious$0$0Feb 19, 2003Closed
Citation 1, item 2d
29 CFR 1926.452(c)(3) · Rules for each type of scaffold
Serious$0$0Feb 19, 2003Closed
Citation 1, item 3a
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Serious$1,500$900Feb 19, 2003Closed
Citation 1, item 3b
29 CFR 1926.451(f)(7) · Scaffolds, general requirements
Serious$0$0Feb 19, 2003Closed
Citation 1, item 3c
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$0$0Feb 19, 2003Closed
Citation 1, item 4
29 CFR 1926.501(b)(11) · Fall protection in construction
Serious$1,500$900Feb 19, 2003Closed

Inspection 301179446 OPENED NOV 18, 1997Closed

Unprogrammed other · Partial · Safety · 2 employees at the site · Closed May 20, 1998

4900 S. Ulster Parkway, Denver, CO 80237 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.102(a)(1) · Eye and face protection in construction
Serious$300$300Dec 11, 1997Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.135 · Head protection

29 CFR 1910.135(a)(1)

(a) General requirements. (1) The employer shall ensure that each affected employee wears a protective helmet when working in areas where there is a potential for injury to the head from falling objects.

29 CFR 1926.100 · Hard hats in construction

29 CFR 1926.100(a)

(a) Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, shall be protected by protective helmets.

29 CFR 1926.102 · Eye and face protection in construction

29 CFR 1926.102(a)(1)

(a) General. (1) The employer shall ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.20 · Construction safety programs

29 CFR 1926.304 · Woodworking tools

29 CFR 1926.416 · Electrical safety in construction

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.454 · Scaffold training

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.503 · Fall protection training in construction

Other framing contractors employers in Colorado

Alert subscribers get notified of each newly cited employer in Colorado the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.