Maselter Cabinets, Inc. has 2 OSHA inspections on record in Minnesota, the first in 2007.
OSHA's last visit started on Nov 23, 2020 as a planned inspection, in Rockville.
Across those inspections OSHA issued 7 citation items: 6 serious and 1 other-than-serious.
OSHA proposed $2,425 in penalties. After settlements and reviews the total is $1,698, down 30%.
Most often, OSHA cited 1910.213, woodworking machinery (2 items).
For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $3,600. Maselter Cabinets, Inc. averages $892 over 1 cited inspection in that time.
Maselter Cabinets, Inc. also files yearly injury logs with OSHA, summarized below.
Citation items per year, by inspection date.
Minnesota · latest 90 days of OSHA records
371employers cited
5 of them in the same industry
Get notified the morning OSHA posts each new citation in Minnesota: the employer, the site address, the rules broken and the penalty.
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2023, the Rockville site logged 1 recordable injury or illness among about 25 workers: 3.8 per 100 full-time workers, against a median of 3.7 for its industry.
Site and year
Workers
Cases
Days-away cases
Rate
Industry median
Maselter Cabinets, Inc.
Rockville · 2023
25
1
0
3.8
3.7
Maselter Cabinets Creative Cabinets, Inc.
Rockville · 2022
28
1
1
3.6
3.7
Included with any plan: 4 more yearly logs from these sites, back to 2017, with each site's average rate over its latest three years. Already a subscriber? Sign in.
(iv) Ventilation. Every inside storage room shall be provided with either a gravity or a mechanical exhaust ventilation system. Such system shall be designed to provide for a complete change of air within the room at least six times per hour. If a mechanical exhaust system is used, it shall be controlled by a switch located outside of the door. The ventilating equipment and any lighting fixtures shall be operated by the same switch. A pilot light shall be installed adjacent to the switch if Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), are dispensed within the room. Where gravity ventilation is provided, the fresh air intake, as well as the exhaust outlet from the room, shall be on the exterior of the building in which the room is located.
29 CFR 1910.106(e)(6)(ii)
(ii) Grounding. Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), shall not be dispensed into containers unless the nozzle and container are electrically interconnected. Where the metallic floorplate on which the container stands while filling is electrically connected to the fill stem or where the fill stem is bonded to the container during filling operations by means of a bond wire, the provisions of this section shall be deemed to have been complied with.
(i) The spraying operations except electrostatic spraying operations shall be so designed, installed and maintained that the average air velocity over the open face of the booth (or booth cross section during spraying operations) shall be not less than 100 linear feet per minute. Electrostatic spraying operations may be conducted with an air velocity over the open face of the booth of not less than 60 linear feet per minute, or more, depending on the volume of the finishing material being applied and its flammability and explosion characteristics. Visible gauges or audible alarm or pressure activated devices shall be installed to indicate or insure that the required air velocity is maintained. Filter rolls shall be inspected to insure proper replacement of filter media.
Alert subscribers get notified of each newly cited employer in Minnesota the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.