Inspection 348483629 OPENED SEP 4, 2025Closed
10165 Sw Commerce Cir Ste E, Wilsonville, OR 97070 · Other Leather and Allied Product Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Wilsonville, Oregon · Other Leather and Allied Product Manufacturing · NAICS 316991
OSHA has inspected Maxline Custom Cases LLC 6 times in Oregon since 2001.
The latest one began on Sep 4, 2025 as a planned inspection, in Wilsonville.
Those inspections ended with 24 citation items: 17 serious and 7 other-than-serious.
Penalties were first proposed at $1,845 and still stand at $1,845.
Spray painting and finishing comes up most often in these citations: 7 items under 1910.107.
How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $4,874, and Maxline Custom Cases LLC averages $120 (1 cited inspection).
Oregon · latest 90 days of OSHA records
384employers cited
Get notified the morning OSHA posts each new citation in Oregon: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Oregon
Checking a subcontractor, a client or your own company? Watch Maxline Custom Cases LLC and get notified the morning OSHA posts a new citation for it.
Watch this company10165 Sw Commerce Cir Ste E, Wilsonville, OR 97070 · Other Leather and Allied Product Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
10165 Sw Commerce Cir Ste E, Wilsonville, OR 97070 · Other Leather and Allied Product Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1910.134(e)(1) · Respiratory protection |
Serious | $120 | $120 | Jul 28, 2017 | Final |
| Citation 1, item 1b 29 CFR 1910.134(f)(2) · Respiratory protection |
Serious | $0 | $0 | Jul 28, 2017 | Final |
| Citation 1, item 1c 29 CFR 1910.134(c)(1) · Respiratory protection |
Serious | $0 | $0 | Jul 28, 2017 | Final |
| Citation 2, item 2 29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods |
Other-than-serious | $0 | $0 | Jul 28, 2017 | Final |
10165 Sw Commerce Cir Ste E, Wilsonville, OR 97070 · Other Leather and Allied Product Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
10165 Sw Commerce Cir Ste F, Wilsonville, OR 97070 · Wood Container and Pallet Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.23(e)(1) · Guarding floor and wall openings and holes |
Serious | $100 | $100 | Jul 9, 2010 | Closed |
| Citation 1, item 2 | Serious | $165 | $165 | Jul 9, 2010 | Closed |
| Citation 2, item 3 | Other-than-serious | $0 | $0 | Jul 9, 2010 | Closed |
2828 Nw Nela St, Portland, OR 97210 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.107(g)(2) · Spray painting and finishing |
Serious | $100 | $100 | Oct 19, 2001 | Closed |
| Citation 1, item 2a 29 CFR 1910.107(b)(5)(iv) · Spray painting and finishing |
Serious | $275 | $275 | Oct 19, 2001 | Closed |
| Citation 1, item 2b 29 CFR 1910.107(b)(1) · Spray painting and finishing |
Serious | $0 | $0 | Oct 19, 2001 | Closed |
| Citation 1, item 2c 29 CFR 1910.107(c)(8) · Spray painting and finishing |
Serious | $0 | $0 | Oct 19, 2001 | Closed |
| Citation 1, item 2d 29 CFR 1910.107(d)(2) · Spray painting and finishing |
Serious | $0 | $0 | Oct 19, 2001 | Closed |
| Citation 1, item 3 29 CFR 1910.107(c)(6) · Spray painting and finishing |
Serious | $165 | $165 | Oct 19, 2001 | Closed |
| Citation 1, item 4 29 CFR 1910.242(b) · Hand and power tools |
Serious | $165 | $165 | Oct 19, 2001 | Closed |
| Citation 2, item 5 29 CFR 1910.107(b)(5)(i) · Spray painting and finishing |
Other-than-serious | $0 | $0 | Oct 19, 2001 | Closed |
2828 Nw Nela St, Portland, OR 97210 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.213(i)(1) · Woodworking machinery |
Serious | $125 | $125 | Jul 20, 2001 | Closed |
| Citation 1, item 2 | Serious | $165 | $165 | Jul 20, 2001 | Closed |
| Citation 1, item 3 29 CFR 1910.215(a)(2) · Grinders and abrasive wheels |
Serious | $100 | $100 | Jul 20, 2001 | Closed |
| Citation 1, item 4 29 CFR 1910.215(b)(9) · Grinders and abrasive wheels |
Serious | $100 | $100 | Jul 20, 2001 | Closed |
| Citation 1, item 5 29 CFR 1910.23(c)(1) · Guarding floor and wall openings and holes |
Serious | $165 | $165 | Jul 20, 2001 | Closed |
| Citation 2, item 6a 29 CFR 1910.1200(e)(1) · Hazard communication |
Other-than-serious | $0 | $0 | Jul 20, 2001 | Closed |
| Citation 2, item 6b 29 CFR 1910.1200(h)(1) · Hazard communication |
Other-than-serious | $0 | $0 | Jul 20, 2001 | Closed |
| Citation 2, item 6c 29 CFR 1910.1200(f)(9) · Hazard communication |
Other-than-serious | $0 | $0 | Jul 20, 2001 | Closed |
| Citation 2, item 7 | Other-than-serious | $100 | $100 | Jul 20, 2001 | Closed |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.107(b)(1)
(b) Spray booths—(1) Construction. Spray booths shall be substantially constructed of steel, securely and rigidly supported, or of concrete or masonry except that aluminum or other substantial noncombustible material may be used for intermittent or low volume spraying. Spray booths shall be designed to sweep air currents toward the exhaust outlet.
29 CFR 1910.107(b)(5)(i)
(i) The spraying operations except electrostatic spraying operations shall be so designed, installed and maintained that the average air velocity over the open face of the booth (or booth cross section during spraying operations) shall be not less than 100 linear feet per minute. Electrostatic spraying operations may be conducted with an air velocity over the open face of the booth of not less than 60 linear feet per minute, or more, depending on the volume of the finishing material being applied and its flammability and explosion characteristics. Visible gauges or audible alarm or pressure activated devices shall be installed to indicate or insure that the required air velocity is maintained. Filter rolls shall be inspected to insure proper replacement of filter media.
29 CFR 1910.107(b)(5)(iv)
(iv) Space within the spray booth on the downstream and upstream sides of filters shall be protected with approved automatic sprinklers.
Alert subscribers get notified of each newly cited employer in Oregon the morning it is posted. See the alert plans.