OSHA SearchOSHA records by employer

MB Construction, LLC: OSHA inspections and violations

Pilot Point, Texas · All Other Specialty Trade Contractors · NAICS 238990

1inspections
6citation items
$5,488current penalties
Oct 2, 2015last inspection

OSHA has inspected MB Construction, LLC once in Texas.

The inspection began on Oct 2, 2015 as a planned inspection, in Pilot Point.

That inspection ended with 6 citation items: 6 serious.

Penalties were first proposed at $10,640 and now stand at $5,488, 48% lower after settlements or reviews.

Scaffolds, general requirements comes up most often in these citations: 2 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,079, and MB Construction, LLC averages $5,488 (1 cited inspection).

MB Construction, LLC: OSHA citation items per year, 2015 to 2015
Citation items per year, by inspection date.

Want to know if OSHA cites MB Construction, LLC again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 340962448 OPENED OCT 2, 2015Closed

Planned · Partial · Safety · 8 employees at the site · Closed Dec 3, 2015

11320 St Johns Road, Pilot Point, TX 76258 · All Other Specialty Trade Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.100(a) · Hard hats in construction
Serious$1,440$1,008Nov 4, 2015Final
Citation 1, item 2a
29 CFR 1926.403(e) · Electrical equipment on job sites
Serious$1,800$1,260Nov 4, 2015Final
Citation 1, item 2b
29 CFR 1926.405(g)(2)(iv) · Job-site wiring
Serious$0$0Nov 4, 2015Final
Citation 1, item 3a
29 CFR 1926.451(c)(2)(iv) · Scaffolds, general requirements
Serious$1,800$1,260Nov 4, 2015Final
Citation 1, item 3b
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$2,800$0Nov 4, 2015Final
Citation 1, item 5
29 CFR 1926.602(d) · Earthmovers and forklifts in construction
Serious$2,800$1,960Nov 4, 2015Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.100 · Hard hats in construction

29 CFR 1926.100(a)

(a) Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, shall be protected by protective helmets.

29 CFR 1926.403 · Electrical equipment on job sites

29 CFR 1926.403(e)

(e) Splices. Conductors shall be spliced or joined with splicing devices designed for the use or by brazing, welding, or soldering with a fusible metal or alloy. Soldered splices shall first be so spliced or joined as to be mechanically and electrically secure without solder and then soldered. All splices and joints and the free ends of conductors shall be covered with an insulation equivalent to that of the conductors or with an insulating device designed for the purpose.

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.405(g)(2)(iv)

(iv) Strain relief. Flexible cords shall be connected to devices and fittings so that strain relief is provided which will prevent pull from being directly transmitted to joints or terminal screws.