OSHA SearchOSHA records by employer

Mba General Contracting, LLC: OSHA inspections and violations

Blackfoot, Idaho · Commercial and Institutional Building Construction · NAICS 236220

2inspections
8citation items
$10,800current penalties
Jun 21, 2016last inspection

Since 2008, OSHA inspectors have visited Mba General Contracting, LLC in Idaho 2 times.

The most recent inspection opened on Jun 21, 2016 on a referral, in Pocatello.

In all, OSHA issued 8 citation items: 7 serious and 1 repeat.

The proposed penalties came to $17,500; today they stand at $10,800, 38% less.

The rule cited most here is 1926.1053 (ladders in construction), 5 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Mba General Contracting, LLC averages $10,800 across 1 cited inspection.

Mba General Contracting, LLC: OSHA citation items per year, 2008 to 2016
Citation items per year, by inspection date.

Idaho · latest 90 days of OSHA records

62employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in Idaho: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Idaho

Checking a subcontractor, a client or your own company? Watch Mba General Contracting, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341567501 OPENED JUN 21, 2016Closed

Referral · Partial · Safety · 35 employees at the site · Closed Nov 28, 2016

1350 Baldy Avenue, Pocatello, ID 83201 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.20(b)(2) · Construction safety programs
Serious$4,900$3,000Jul 5, 2016Final
Citation 1, item 1b
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$0$0Jul 5, 2016Final
Citation 1, item 2a
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$2,800$1,400Jul 5, 2016Final
Citation 1, item 2b
29 CFR 1926.1053(b)(8) · Ladders in construction
Serious$0$0Jul 5, 2016Final
Citation 1, item 3a
29 CFR 1926.1053(b)(3) · Ladders in construction
Serious$2,800$1,400Jul 5, 2016Final
Citation 1, item 3b
29 CFR 1926.1053(b)(15) · Ladders in construction
Serious$0$0Jul 5, 2016Final
Citation 1, item 3c
29 CFR 1926.1053(b)(16) · Ladders in construction
Serious$0$0Jul 5, 2016Final
Citation 2, item 1
29 CFR 1926.652(a)(1) · Trench protection
Repeat$7,000$5,000Jul 5, 2016Final

Inspection 311578579 OPENED SEP 17, 2008Closed

Referral · Complete · Safety · 4 employees at the site · Closed Dec 8, 2008

98 Poplar Street, Blackfoot, ID 83221 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.1053(b)(15)

(15) Ladders shall be inspected by a competent person for visible defects on a periodic basis and after any occurrence that could affect their safe use.

29 CFR 1926.1053(b)(16)

(16) Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, shall either be immediately marked in a manner that readily identifies them as defective, or be tagged with “Do Not Use” or similar language, and shall be withdrawn from service until repaired.

29 CFR 1926.20 · Construction safety programs

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.652 · Trench protection

Other commercial and institutional building construction employers in Idaho

Alert subscribers get notified of each newly cited employer in Idaho the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.