OSHA SearchOSHA records by employer

MCS Communication, LLC: OSHA inspections and violations

Pella, Iowa · Electrical Contractors and Other Wiring Installation Contractors · NAICS 238210

1inspections
7citation items
$12,250current penalties
Aug 3, 2020last inspection

OSHA has inspected MCS Communication, LLC once in Iowa.

The inspection began on Aug 3, 2020 after a fatality or catastrophe, in Pella.

That inspection ended with 7 citation items: 4 serious and 3 other-than-serious.

Penalties were first proposed at $16,231 and now stand at $12,250, 25% lower after settlements or reviews.

Electrical safety in construction comes up most often in these citations: 2 items under 1926.416.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and MCS Communication, LLC averages $12,250 (1 cited inspection).

1 inspection on this page followed a fatal incident.

MCS Communication, LLC: OSHA citation items per year, 2020 to 2020
Citation items per year, by inspection date.

Iowa · latest 90 days of OSHA records

69employers cited

Get notified the morning OSHA posts each new citation in Iowa: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Iowa

Checking a subcontractor, a client or your own company? Watch MCS Communication, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344864384 OPENED AUG 3, 2020Closed

Fatality or catastrophe · Partial · Safety · 6 employees at the site · Closed Feb 10, 2021

Lincoln And Main, Pella, IA 50219 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Incident on Aug 1, 2020 (fatal): Two employees are killed when underground power line explode

At 8:30 a.m. on August 1, 2020, Employees #1, #2, and #3, employed by a electrical services company in the telecommunications field, were working on a multi-employer construction project at the intersection of two streets. They were potholing to locate underground utility lines, with the aim to then bore in a new fiber optic line under the intersection. After finding what they thought was over-pour from the concrete curb, they used a Ring-o-matic Vacuum Excavator to excavate over top of the concrete. They then used a jackhammer on the concrete. The jackhammer bit made contact with a 12,470-volt underground electrical distribution line, and an electric arc explosion occurred. Employees #1 and #2 were killed by electrocution. Employee #3, who was knocked down by the force of the explosion, was transported to the hospital, where he was observed, determined to have no injuries, and released.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.21(b)(2) · Construction safety training
Serious$3,978$3,000Oct 22, 2020Final
Citation 1, item 2a
29 CFR 1926.416(a)(2) · Electrical safety in construction
Serious$3,978$6,000Oct 22, 2020Final
Citation 1, item 2b
29 CFR 1926.416(a)(3) · Electrical safety in construction
Serious$3,978$0Oct 22, 2020Final
Citation 1, item 4
29 CFR 1926.651(b)(3) · Excavations
Serious$3,978$3,000Oct 22, 2020Final
Citation 2, item 1a
29 CFR 1904.29(b)(1) · Injury and illness log
Other-than-serious$319$250Oct 22, 2020Final
Citation 2, item 1b
29 CFR 1904.29(b)(4) · Injury and illness log
Other-than-serious$0$0Oct 22, 2020Final
Citation 2, item 1c
29 CFR 1904.40(a) · Giving injury records to OSHA
Other-than-serious$0$0Oct 22, 2020Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1904.29 · Injury and illness log

29 CFR 1904.29(b)(1)

(b) Implementation—(1) What do I need to do to complete the OSHA 300 Log? You must enter information about your business at the top of the OSHA 300 Log, enter a one or two line description for each recordable injury or illness, and summarize this information on the OSHA 300-A at the end of the year.

29 CFR 1904.29(b)(4)

(4) What is an equivalent form? An equivalent form is one that has the same information, is as readable and understandable, and is completed using the same instructions as the OSHA form it replaces. Many employers use an insurance form instead of the OSHA 301 Incident Report, or supplement an insurance form by adding any additional information required by OSHA.

29 CFR 1904.40 · Giving injury records to OSHA

29 CFR 1904.40(a)

(a) Basic requirement. When an authorized government representative asks for the records you keep under part 1904, you must provide copies of the records within four (4) business hours.

29 CFR 1926.21 · Construction safety training

29 CFR 1926.416 · Electrical safety in construction

29 CFR 1926.651 · Excavations

Other electrical contractors and other wiring installation contractors employers in Iowa

Alert subscribers get notified of each newly cited employer in Iowa the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.