OSHA SearchOSHA records by employer

Meadors Construction Corporation: OSHA inspections and violations

Charleston, South Carolina · Commercial and Institutional Building Construction · NAICS 236220

7inspections
16citation items
$11,800current penalties
Dec 6, 2016last inspection

OSHA has inspected Meadors Construction Corporation 7 times in South Carolina since 1996.

The latest one began on Dec 6, 2016 to follow up on an earlier case, in Charleston.

Those inspections ended with 16 citation items: 16 serious.

Penalties were first proposed at $22,375 and now stand at $11,800, 47% lower after settlements or reviews.

Scaffolds, general requirements comes up most often in these citations: 7 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Meadors Construction Corporation averages $4,088 (2 cited inspections).

Meadors Construction Corporation: OSHA citation items per year, 1996 to 2016
Citation items per year, by inspection date.

South Carolina · latest 90 days of OSHA records

42employers cited

5 of them in the same industry

Get notified the morning OSHA posts each new citation in South Carolina: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in South Carolina

Checking a subcontractor, a client or your own company? Watch Meadors Construction Corporation and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341954394 OPENED DEC 6, 2016Closed

Follow-up · Partial · Safety · 4 employees at the site · Closed Apr 6, 2017

121 Chruch Street, Charleston, SC 29401 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.405(j)(1)(i) · Job-site wiring
Serious$675$675Feb 21, 2017Final

Inspection 341403459 OPENED APR 14, 2016Closed

Fatality or catastrophe · Partial · Safety · 6 employees at the site · Closed Apr 6, 2017

121 Church Street, Charleston, SC 29401 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.21(b)(2) · Construction safety training
Serious$2,500$1,250Sep 28, 2016Final
Citation 1, item 2
29 CFR 1926.100(a) · Hard hats in construction
Serious$2,500$1,250Sep 28, 2016Final
Citation 1, item 3
29 CFR 1926.405(b)(1) · Job-site wiring
Serious$1,000$500Sep 28, 2016Final
Citation 1, item 4
29 CFR 1926.651(h)(1) · Excavations
Serious$3,000$1,500Sep 28, 2016Final
Citation 1, item 5
29 CFR 1926.651(k)(1) · Excavations
Serious$3,000$1,500Sep 28, 2016Final
Citation 1, item 6
29 CFR 1926.652(a)(1) · Trench protection
Serious$4,200$1,500Sep 28, 2016Final

Inspection 316198746 OPENED JAN 4, 2012Closed

Planned · No inspection · Safety · Closed Jan 13, 2012

411 Sunset Drive, Manning, SC 29102 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 315185637 OPENED DEC 15, 2010Closed

Planned · Complete · Safety · 6 employees at the site · Closed May 6, 2011

211 North Brooks Street, Manning, SC 29102 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 6
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$3,000$1,500Jan 24, 2011Closed
Citation 1, item 7
29 CFR 1926.451(f)(7) · Scaffolds, general requirements
Serious$2,500$1,250Jan 24, 2011Closed
Citation 1, item 8a
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$0$438Jan 24, 2011Final
Citation 1, item 8b
29 CFR 1926.451(b)(2) · Scaffolds, general requirements
Serious$0$0Jan 24, 2011Closed
Citation 1, item 9a
29 CFR 1926.451(c)(1)(ii) · Scaffolds, general requirements
Serious$0$438Jan 24, 2011Closed
Citation 1, item 9b
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Serious$0$0Jan 24, 2011Closed
Citation 1, item 9c
29 CFR 1926.451(c)(3) · Scaffolds, general requirements
Serious$0$0Jan 24, 2011Closed

Inspection 310967872 OPENED MAY 22, 2007Closed

Referral · No inspection · Safety · Closed Jun 15, 2007

18 Lamboll Street, Charleston, SC 29401 · Residential Remodelers · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 301770640 OPENED JUL 28, 1998Closed

Unprogrammed related · Partial · Health · 7 employees at the site · Closed Jan 5, 2011

115 Broad St., Charleston, SC 29401 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 126501550 OPENED JUL 11, 1996Closed

Planned · Partial · Safety · 4 employees at the site · Closed Jul 30, 1996

Blanding Street, Columbia, SC 29201 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.100(a) · Hard hats in construction
Serious$0$0Jul 30, 1996Closed
Citation 1, item 2 Serious$0$0Jul 30, 1996Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.100 · Hard hats in construction

29 CFR 1926.100(a)

(a) Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, shall be protected by protective helmets.

29 CFR 1926.21 · Construction safety training

29 CFR 1926.21(b)(2)

(2) The employer shall instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his work environment to control or eliminate any hazards or other exposure to illness or injury.

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.405(b)(1)

(b) Cabinets, boxes, and fittings—(1) Conductors entering boxes, cabinets, or fittings. Conductors entering boxes, cabinets, or fittings shall be protected from abrasion, and openings through which conductors enter shall be effectively closed. Unused openings in cabinets, boxes, and fittings shall also be effectively closed.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.556

29 CFR 1926.651 · Excavations

29 CFR 1926.652 · Trench protection

Other commercial and institutional building construction employers in South Carolina

Alert subscribers get notified of each newly cited employer in South Carolina the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.