OSHA SearchOSHA records by employer

Medere Home Improvements: OSHA inspections and violations

Toledo, Ohio · Siding Contractors · NAICS 238170

3inspections
9citation items
$9,742current penalties
Jan 14, 2020last inspection

Medere Home Improvements has 3 OSHA inspections on record in Ohio, the first in 2007.

OSHA's last visit started on Jan 14, 2020 as a planned inspection, in Waterville.

Across those inspections OSHA issued 9 citation items: 8 serious and 1 repeat.

OSHA proposed $18,229 in penalties. After settlements and reviews the total is $9,742, down 47%.

Most often, OSHA cited 1926.451, scaffolds, general requirements (4 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Medere Home Improvements averages $4,331 over 2 cited inspections in that time.

Medere Home Improvements: OSHA citation items per year, 2007 to 2020
Citation items per year, by inspection date.

Ohio · latest 90 days of OSHA records

260employers cited

4 of them in the same industry

Get notified the morning OSHA posts each new citation in Ohio: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Ohio

Checking a subcontractor, a client or your own company? Watch Medere Home Improvements and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344558929 OPENED JAN 14, 2020Closed

Planned · Complete · Safety · 4 employees at the site · Closed Oct 6, 2021

1473 Falcon Cove (lot 22), Waterville, OH 43566 · Siding Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.100(a) · Hard hats in construction
Serious$2,545$1,272Jan 29, 2020Final
Citation 1, item 2
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$3,181$1,590Jan 29, 2020Final
Citation 2, item 1
29 CFR 1926.451(g)(1)(i) · Scaffolds, general requirements
Repeat$6,362$3,181Jan 29, 2020Final

Inspection 341844587 OPENED OCT 14, 2016Closed

Planned · Partial · Safety · 4 employees at the site · Closed Aug 1, 2017

5609 Harris Hawk Lane, Sylvania, OH 43560 · Siding Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(g)(1)(i) · Scaffolds, general requirements
Serious$3,741$2,619Nov 7, 2016Final

Inspection 309447753 OPENED MAY 30, 2007Closed

Planned · Complete · Safety · 2 employees at the site · Closed Mar 7, 2008

Brody's Trace Addition, Toledo, OH 43606 · Siding Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(f)(1) · Scaffolds, general requirements
Serious$600$270Jun 18, 2007Closed
Citation 1, item 2
29 CFR 1926.451(g)(1)(i) · Scaffolds, general requirements
Serious$600$270Jun 18, 2007Closed
Citation 1, item 3
29 CFR 1926.452(k)(3) · Rules for each type of scaffold
Serious$600$270Jun 18, 2007Closed
Citation 1, item 4a
29 CFR 1926.454(a) · Scaffold training
Serious$600$270Jun 18, 2007Closed
Citation 1, item 4b
29 CFR 1926.20(b)(2) · Construction safety programs
Serious$0$0Jun 18, 2007Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.100 · Hard hats in construction

29 CFR 1926.100(a)

(a) Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, shall be protected by protective helmets.

29 CFR 1926.20 · Construction safety programs

29 CFR 1926.20(b)(2)

(2) Such programs shall provide for frequent and regular inspections of the job sites, materials, and equipment to be made by competent persons designated by the employers.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(f)(1)

(f) Use. (1) Scaffolds and scaffold components shall not be loaded in excess of their maximum intended loads or rated capacities, whichever is less.

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.454 · Scaffold training

29 CFR 1926.501 · Fall protection in construction

Other siding contractors employers in Ohio

Alert subscribers get notified of each newly cited employer in Ohio the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.