OSHA SearchOSHA records by employer

Merit Erectors, Inc: OSHA inspections and violations

Batavia, Ohio · Structural Steel and Precast Concrete Contractors · NAICS 238120

1inspections
6citation items
$13,300current penalties
Oct 13, 2016last inspection

OSHA inspectors have visited Merit Erectors, Inc in Ohio one time.

It opened on Oct 13, 2016 after a complaint, in Batavia.

In all, OSHA issued 6 citation items: 6 serious.

The proposed penalties came to $44,365; today they stand at $13,300, 70% less.

The rule cited most here is 1926.757 (open web steel joists), 5 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Merit Erectors, Inc averages $13,300 across 1 cited inspection.

Merit Erectors, Inc: OSHA citation items per year, 2016 to 2016
Citation items per year, by inspection date.

Ohio · latest 90 days of OSHA records

267employers cited

Get notified the morning OSHA posts each new citation in Ohio: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Ohio

Checking a subcontractor, a client or your own company? Watch Merit Erectors, Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341837169 OPENED OCT 13, 2016Closed

Complaint · Partial · Safety · 40 employees at the site · Closed Mar 16, 2017

4101 Bach-buxton Road, Batavia, OH 45103 · Structural Steel and Precast Concrete Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.20(b)(2) · Construction safety programs
Serious$8,873$8,873Feb 7, 2017Final
Citation 1, item 1b
29 CFR 1926.757(a)(6) · Open web steel joists
Serious$8,873$0Feb 7, 2017Final
Citation 1, item 1c
29 CFR 1926.757(c)(1) · Open web steel joists
Serious$0$0Feb 7, 2017Final
Citation 1, item 1d
29 CFR 1926.757(d)(1)(ii) · Open web steel joists
Serious$8,873$0Feb 7, 2017Final
Citation 1, item 4a
29 CFR 1926.757(e)(1) · Open web steel joists
Serious$8,873$4,427Feb 7, 2017Final
Citation 1, item 4b
29 CFR 1926.757(e)(2) · Open web steel joists
Serious$8,873$0Feb 7, 2017Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.20 · Construction safety programs

29 CFR 1926.20(b)(2)

(2) Such programs shall provide for frequent and regular inspections of the job sites, materials, and equipment to be made by competent persons designated by the employers.

29 CFR 1926.757 · Open web steel joists

29 CFR 1926.757(a)(6)

(6) When steel joist(s) are landed on a structure, they shall be secured to prevent unintentional displacement prior to installation.

29 CFR 1926.757(c)(1)

(c) Erection of steel joists. (1) Both sides of the seat of one end of each steel joist that requires bridging under Tables A and B shall be attached to the support structure before hoisting cables are released.

Other structural steel and precast concrete contractors employers in Ohio

Alert subscribers get notified of each newly cited employer in Ohio the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.