Incident on May 10, 2001: Employee became sick when exposed to fumes and lead
On May 10, 2001, Employee #1, a main torch cutter, and another worker, a supervi sor, began work at Reed College. The sports center at Reed College was undergoin g a large demolition and remodeling project. In the course of the project, it wa s discovered that an old indoor rifle range backstop was encased behind one of t he walls. The backstop consisted of an about 10-ft by 20-ft piece of a steel pla te mounted at a forward pointing angle and of a long trench, which was filled wi th sand at its base. The company had the sand tested for lead prior to commencin g demolition works, and the results were negative; lead was not detected. The ou tside surface of the steel plate was not painted. Employee #1 and another worker from the Metal Enterprises were sub-contracted by the Reimers and Jolivette Inc orporated to remove the steel plate backstop. They used cutting torches to cut t he backstop into approximately 2-ft by 2-ft pieces. Employee #1 was most heavily exposed to metal fumes. Another employee from Reimers and Jolivette Incorporate d was a fire-watch. Employee #1, another worker, and the fire-watch were wearing the N-95 dust respirators. The job lasted two days. On the second day Employee #1 completed the work without another worker, but in the presence of the fire-wa tch. At the end of the second day, Employee #1 began to experience severe respir atory problem and was taken to the hospital. After the work was completed, they realized that the back side of the steel plate was painted with several layers o f the "red-lead" paint. The paint was tested and found to contain 20 percent of lead. The back side of the steel plate was covered with thick layer of soot and it would not have been readily apparent that it was painted at all. Employee #1 remained in the hospital for two nights. A series of blood tests were made and a significant concentration of lead, such as 58 micrograms per deciliter, was fou nd. Another worker was also tested and found to have a blood lead level of only 8 micrograms per deciliter. The fire-watch employee was asked to have his blood tested, but he refused. Employee #1 was released from the hospital on May 12, 20 01 and returned to full duty on May 14, 2001. The follow-up blood testing for le ad was conducted on May 16, 2001, showing a lead level of 47 micrograms per deci liter. This extreme drop over a short time suggests acute lead poisoning. Employ ee #1 disclosed that he had experienced high blood lead episodes during his prev ious job as a welder at Exxon. He was in Exxon's lead medical monitoring program for an extended period of time and remembered having one lead level as high as 42 micrograms per deciliter. Employee #1 was a new employee at Metal Enterprises , hired one month earlier. He had previously worked in the Esco Foundry for 4 mo nths and for Exxon in Louisiana for 12 years. Employee #1's health conditions on May 5, 2001, were a combined result of exposure to miscellaneous cutting fumes, lead, and pre-existing flu symptoms.
No citations from this inspection.