OSHA SearchOSHA records by employer

Metropolitan Rolling Door, Inc.: OSHA inspections and violations

Columbia, Maryland · Other Building Material Dealers · NAICS 444190

4inspections
17citation items
$2,599current penalties
Oct 25, 2018last inspection

Metropolitan Rolling Door, Inc. has 4 OSHA inspections on record in Maryland, the first in 1986.

OSHA's last visit started on Oct 25, 2018 after an accident, in Columbia.

Across those inspections OSHA issued 17 citation items: 9 serious and 8 other-than-serious.

OSHA proposed $5,775 in penalties. After settlements and reviews the total is $2,599, down 55%.

Most often, OSHA cited 1910.1200, hazard communication (3 items).

For context, across all retail employers the median penalty per cited inspection since 2015 is $1,750. Metropolitan Rolling Door, Inc. averages $2,599 over 1 cited inspection in that time.

Metropolitan Rolling Door, Inc.: OSHA citation items per year, 1986 to 2018
Citation items per year, by inspection date.

Maryland · latest 90 days of OSHA records

189employers cited

Get notified the morning OSHA posts each new citation in Maryland: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Maryland

Checking a subcontractor, a client or your own company? Watch Metropolitan Rolling Door, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343562484 OPENED OCT 25, 2018Closed

Accident · Partial · Safety · 31 employees at the site · Closed Dec 18, 2018

9620 Gerwig Lane, Columbia, MD 21046 · Other Building Material Dealers · OSHA's record · Phone and website on Google Maps

Incident on Oct 25, 2018: Employee fractures leg when struck by steel tubes

At 11:15 a.m. on October 25, 2018, Employee #1 was moving a bundle of four inch by four inch, 20-foot long steel tubes with a forklift onto a truck. The steel tubes were bundled together with 0.25 inch thick metal bandings. Each bundle contained four tubes. While moving one of the bundles of the tubes, the forklift cut off, leaving the forks tilted in a downward angle. Employee #1 then obtained a boom lift that was on site, to move the steel tubes. The boom lift could only pick up one tube at a time, so the employee needed to cut the metal banding surrounding the steel tubes. As he bent down in front of the bundle of tubes, the employee cut the metal banding and the tubes rolled onto his legs, fracturing one of them. He was hospitalized for treatment.

No citations from this inspection.

Inspection 341207348 OPENED JAN 27, 2016Closed

Planned · Complete · Safety · 8 employees at the site · Closed May 17, 2016

9620 Gerwig Lane, Columbia, MD 21046 · Other Building Material Dealers · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.22(d)(1) · General requirements
Serious$1,225$551Apr 13, 2016Final
Citation 1, item 2
29 CFR 1910.178(l)(1)(i) · Forklifts and other powered industrial trucks
Serious$1,225$551Apr 13, 2016Final
Citation 1, item 3a
29 CFR 1910.212(a)(1) · Machine guarding
Serious$1,050$473Apr 13, 2016Final
Citation 1, item 3b
29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts
Serious$0$0Apr 13, 2016Final
Citation 1, item 3c
29 CFR 1910.219(e)(3)(i) · Belts, pulleys and power-transmission parts
Serious$0$0Apr 13, 2016Final
Citation 1, item 4a
29 CFR 1910.253(b)(2)(ii) · Gas welding and cutting
Serious$1,225$551Apr 13, 2016Final
Citation 1, item 4b
29 CFR 1910.253(b)(2)(iv) · Gas welding and cutting
Serious$0$0Apr 13, 2016Final
Citation 1, item 5a
29 CFR 1910.304(g)(5) · Grounding and circuit protection
Serious$1,050$473Apr 13, 2016Final
Citation 1, item 5b
29 CFR 1910.305(b)(2)(i) · Electrical wiring methods
Serious$0$0Apr 13, 2016Final
Citation 2, item 1
29 CFR 1910.132(d)(2) · Personal protective equipment, general requirements
Other-than-serious$0$0Apr 13, 2016Final
Citation 2, item 2
29 CFR 1910.157(c)(1) · Portable fire extinguishers
Other-than-serious$0$0Apr 13, 2016Final
Citation 2, item 3
29 CFR 1910.303(g)(2)(ii) · Electrical equipment, general requirements
Other-than-serious$0$0Apr 13, 2016Final
Citation 2, item 4
29 CFR 1910.1200(e)(1) · Hazard communication
Other-than-serious$0$0Apr 13, 2016Final
Citation 2, item 5
29 CFR 1910.1200(e)(1)(i) · Hazard communication
Other-than-serious$0$0Apr 13, 2016Final
Citation 2, item 6
29 CFR 1910.1200(f)(6)(ii) · Hazard communication
Other-than-serious$0$0Apr 13, 2016Final

Inspection 303337117 OPENED APR 20, 2000Closed

Planned · Complete · Safety · 3 employees at the site · Closed Aug 8, 2000

4900 Washington Boulevard, Halethorpe, MD 21227 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.416(e)(1) · Electrical safety in construction
Other-than-serious$0$0Jun 7, 2000Closed

Inspection 18872952 OPENED AUG 11, 1986Closed

Planned · Complete · Safety · 2 employees at the site · Closed Nov 5, 1986

Oppossumtown Pike, Frederick, MD 21701 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.351(b)(4) · Arc welding and cutting
Other-than-serious$0$0Oct 8, 1986Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(e)(1)

(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:

29 CFR 1910.1200(e)(1)(i)

(i) A list of the hazardous chemicals known to be present using a product identifier that is referenced on the appropriate safety data sheet (the list may be compiled for the workplace as a whole or for individual work areas); and,

29 CFR 1910.1200(f)(6)(ii)

(ii) Product identifier and words, pictures, symbols, or combination thereof, which provide at least general information regarding the hazards of the chemicals, and which, in conjunction with the other information immediately available to employees under the hazard communication program, will provide employees with the specific information regarding the physical and health hazards of the hazardous chemical.

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.212 · Machine guarding

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.22 · General requirements

29 CFR 1910.253 · Gas welding and cutting

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1926.351 · Arc welding and cutting

29 CFR 1926.416 · Electrical safety in construction

Other other building material dealers employers in Maryland

Alert subscribers get notified of each newly cited employer in Maryland the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.