OSHA SearchOSHA records by employer

Metrotransit: OSHA inspections and violations

Saint Paul, Minnesota · Mixed Mode Transit Systems · NAICS 485111

1inspections
2citation items
$8,400current penalties
Jan 23, 2018last inspection

OSHA has inspected Metrotransit once in Minnesota.

The inspection began on Jan 23, 2018, in Saint Paul.

That inspection ended with 2 citation items: 2 serious.

Penalties were first proposed at $14,000 and now stand at $8,400, 40% lower after settlements or reviews.

Working near live electrical parts comes up most often in these citations: 2 items under 1910.333.

How that compares: the median penalty per cited inspection for transportation and warehousing employers since 2015 is $2,415, and Metrotransit averages $8,400 (1 cited inspection).

Metrotransit: OSHA citation items per year, 2018 to 2018
Citation items per year, by inspection date.

Minnesota · latest 90 days of OSHA records

380employers cited

Get notified the morning OSHA posts each new citation in Minnesota: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Minnesota

Checking a subcontractor, a client or your own company? Watch Metrotransit and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342923158 OPENED JAN 23, 2018Closed

Unprogrammed other · Partial · Safety · Local government · 101 employees at the site · Closed Sep 4, 2018

340 Broadway St, Saint Paul, MN 55101 · Mixed Mode Transit Systems · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.333(a)(1) · Working near live electrical parts
Serious$7,000$4,200Jun 21, 2018Final
Citation 1, item 2
29 CFR 1910.333(b)(2)(iv)(a) · Working near live electrical parts
Serious$7,000$4,200Jun 21, 2018Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.333 · Working near live electrical parts

29 CFR 1910.333(a)(1)

(1) Deenergized parts. Live parts to which an employee may be exposed shall be deenergized before the employee works on or near them, unless the employer can demonstrate that deenergizing introduces additional or increased hazards or is infeasible due to equipment design or operational limitations. Live parts that operate at less than 50 volts to ground need not be deenergized if there will be no increased exposure to electrical burns or to explosion due to electric arcs.

29 CFR 1910.333(b)(2)(iv)(a)

(A) A qualified person shall operate the equipment operating controls or otherwise verify that the equipment cannot be restarted.

Other mixed mode transit systems employers in Minnesota

Alert subscribers get notified of each newly cited employer in Minnesota the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.