Inspection 346530728 OPENED FEB 24, 2023Closed
405 Sw Columbia St, Bend, OR 97702 · Printed Circuit Assembly (Electronic Assembly) Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Since 2004, OSHA inspectors have visited Microchip Technology Inc in Oregon 5 times.
The most recent inspection opened on Feb 24, 2023 as a planned inspection, in Bend.
In all, OSHA issued 13 citation items: 9 serious and 4 other-than-serious.
The penalties, $2,510 in total, stand where OSHA first set them.
The rule cited most here is 1910.134 (respiratory protection), 4 times.
Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. Microchip Technology Inc averages $2,300 across 1 cited inspection.
Microchip Technology Inc also files yearly injury logs with OSHA, summarized below.
Want to know if OSHA cites Microchip Technology Inc again? Add it to a watchlist and we will email you the morning the citation shows up.
Watch this company405 Sw Columbia St, Bend, OR 97702 · Printed Circuit Assembly (Electronic Assembly) Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
21015 Se Stark St, Gresham, OR 97030 · Semiconductor and Related Device Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
21015 Se Stark St, Gresham, OR 97030 · Semiconductor and Related Device Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
21015 Se Stark St, Gresham, OR 97030 · Semiconductor and Related Device Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR OAR 437-001-0760(1)(B)(D) |
Serious | $700 | $700 | Mar 2, 2020 | Final |
| Citation 1, item 2a 29 CFR 1910.147(c)(4)(ii) · Lockout/tagout |
Serious | $700 | $700 | Mar 2, 2020 | Final |
| Citation 1, item 2b 29 CFR 1910.147(c)(6)(i) · Lockout/tagout |
Serious | $0 | $0 | Mar 2, 2020 | Final |
| Citation 1, item 3 29 CFR OAR 437-002-0161(5)(A)(A)(V) |
Serious | $300 | $300 | Mar 2, 2020 | Final |
| Citation 1, item 4a 29 CFR 1910.1030(f)(2)(iv) · Bloodborne pathogens |
Serious | $300 | $300 | Mar 2, 2020 | Final |
| Citation 1, item 4b 29 CFR 1910.1030(g)(2)(ii)(b) · Bloodborne pathogens |
Serious | $0 | $0 | Mar 2, 2020 | Final |
| Citation 1, item 4c 29 CFR 1910.1030(h)(2)(i) · Bloodborne pathogens |
Serious | $0 | $0 | Mar 2, 2020 | Final |
| Citation 1, item 5 29 CFR 1910.1025(d)(2) · Lead in general industry |
Serious | $300 | $300 | Mar 2, 2020 | Final |
| Citation 2, item 6 29 CFR OAR 437-002-0146(5)(G)(A) |
Other-than-serious | $0 | $0 | Mar 2, 2020 | Final |
| Citation 2, item 7 29 CFR 1910.134(c)(1)(v) · Respiratory protection |
Other-than-serious | $0 | $0 | Mar 2, 2020 | Final |
| Citation 2, item 8 29 CFR 1910.134(c)(1)(vi) · Respiratory protection |
Other-than-serious | $0 | $0 | Mar 2, 2020 | Final |
| Citation 2, item 9 29 CFR 1910.134(c)(1)(ix) · Respiratory protection |
Other-than-serious | $0 | $0 | Mar 2, 2020 | Final |
21015 Se Stark St, Gresham, OR 97030 · Semiconductor and Related Device Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.134(f)(2) · Respiratory protection |
Serious | $210 | $210 | Oct 29, 2004 | Closed |
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2025, the Gresham site logged 1 recordable injury or illness among about 633 workers: 0.2 per 100 full-time workers, against a median of 0.5 for its industry. Those cases cost 17 days away from work.
| Site and year | Workers | Cases | Days-away cases | Rate | Industry median |
|---|---|---|---|---|---|
| Microchip Technology Inc Gresham OR Gresham · 2025 | 633 | 1 | 1 | 0.2 | 0.5 |
| Microchip Technology Inc Bend OR Bend · 2025 | 23 | 0 | 0 | 0.0 | 0.5 |
| Microchip Technology Inc. Bend · 2023 | 32 | 0 | 0 | 0.0 | 2.1 |
| Gresham FAB-4 Gresham · 2016 | 601 | 7 | 4 | 1.2 | 0.5 |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.1025(d)(2)
(2) Initial determination. Each employer who has a workplace or work operation covered by this standard shall determine if any exployee may be exposed to lead at or above the action level.
29 CFR 1910.1030(f)(2)(iv)
(iv) The employer shall assure that employees who decline to accept hepatitis B vaccination offered by the employer sign the statement in appendix A.
29 CFR 1910.1030(g)(2)(ii)(b)
(B) At least annually thereafter.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.