Microxact, Inc.: OSHA inspections and violations

Radford, Virginia · Semiconductor and Related Device Manufacturing · NAICS 334413

1inspections
5citation items
$1,336current penalties
Apr 17, 2024last inspection

OSHA has inspected Microxact, Inc. once in Virginia.

The inspection began on Apr 17, 2024 after a complaint, in Radford.

That inspection ended with 5 citation items: 5 serious.

Penalties were first proposed at $1,670 and now stand at $1,336, 20% lower after settlements or reviews.

Welding fire safety comes up most often in these citations: 4 items under 1910.252.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and Microxact, Inc. averages $1,336 (1 cited inspection).

Microxact, Inc.: OSHA citation items per year, 2024 to 2024
Citation items per year, by inspection date.

Want to know if OSHA cites Microxact, Inc. again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 347414823 OPENED APR 17, 2024Closed

Complaint · Partial · Health · 6 employees at the site · Closed Jul 1, 2024

6580 Valley Center Drive, Suite 312, Radford, VA 24141 · Semiconductor and Related Device Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.252(b)(2)(iii) · Welding fire safety
Serious$990$792Jun 3, 2024Final
Citation 1, item 1b
29 CFR 1910.252(c)(2)(i)(a) · Welding fire safety
Serious$0$0Jun 3, 2024Final
Citation 1, item 1c
29 CFR 1910.252(c)(2)(i)(c) · Welding fire safety
Serious$0$0Jun 3, 2024Final
Citation 1, item 1d
29 CFR 1910.252(c)(3)(ii) · Welding fire safety
Serious$0$0Jun 3, 2024Final
Citation 1, item 2
29 CFR 1910.253(b)(2)(ii) · Gas welding and cutting
Serious$680$544Jun 3, 2024Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.252 · Welding fire safety

29 CFR 1910.252(b)(2)(iii)

(iii) Protection from arc welding rays. Where the work permits, the welder should be enclosed in an individual booth painted with a finish of low reflectivity such as zinc oxide (an important factor for absorbing ultraviolet radiations) and lamp black, or shall be enclosed with noncombustible screens similarly painted. Booths and screens shall permit circulation of air at floor level. Workers or other persons adjacent to the welding areas shall be protected from the rays by noncombustible or flameproof screens or shields or shall be required to wear appropriate goggles.

29 CFR 1910.252(c)(2)(i)(a)

(A) In a space of less than 10,000 cubic feet (284 m 3) per welder.

29 CFR 1910.252(c)(2)(i)(c)

(C) In confined spaces or where the welding space contains partitions, balconies, or other structural barriers to the extent that they significantly obstruct cross ventilation.

29 CFR 1910.253 · Gas welding and cutting

Other semiconductor and related device manufacturing employers in Virginia