OSHA SearchOSHA records by employer

Mig Exteriors LLC: OSHA inspections and violations

Columbia, South Carolina · Drywall and Insulation Contractors · NAICS 238310

1inspections
4citation items
$2,250current penalties
Jan 6, 2026last inspection

Mig Exteriors LLC has one OSHA inspection on record in South Carolina.

OSHA opened it on Jan 6, 2026 as a planned inspection, in Columbia.

From that inspection OSHA issued 4 citation items: 4 serious.

OSHA proposed $2,250 in penalties and the amount has not been reduced.

Most often, OSHA cited 1926.451, scaffolds, general requirements (4 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Mig Exteriors LLC averages $2,250 over 1 cited inspection in that time.

Mig Exteriors LLC: OSHA citation items per year, 2026 to 2026
Citation items per year, by inspection date.

South Carolina · latest 90 days of OSHA records

42employers cited

Get notified the morning OSHA posts each new citation in South Carolina: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in South Carolina

Checking a subcontractor, a client or your own company? Watch Mig Exteriors LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348676214 OPENED JAN 6, 2026Closed

Planned · Partial · Safety · 5 employees at the site · Closed Sep 10, 2026

136 Harbison Blvd, Columbia, SC 29212 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Serious$500$500Mar 31, 2026Final
Citation 1, item 2
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$500$500Mar 31, 2026Final
Citation 1, item 3
29 CFR 1926.451(h)(1) · Scaffolds, general requirements
Serious$500$500Mar 31, 2026Final
Citation 1, item 4
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Serious$750$750Mar 31, 2026Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(c)(2)

(2) Supported scaffold poles, legs, posts, frames, and uprights shall bear on base plates and mud sills or other adequate firm foundation.

29 CFR 1926.451(e)(1)

(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.

29 CFR 1926.451(f)(3)

(3) Scaffolds and scaffold components shall be inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity.

Other drywall and insulation contractors employers in South Carolina

Alert subscribers get notified of each newly cited employer in South Carolina the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.