OSHA SearchOSHA records by employer

Millville Lumber Co., Inc.: OSHA inspections and violations

Snow Hill, Maryland · Sawmills · NAICS 321113

4inspections
52citation items
$19,679current penalties
Mar 22, 2021last inspection

Since 1994, OSHA inspectors have visited Millville Lumber Co., Inc. in Maryland 4 times.

The most recent inspection opened on Mar 22, 2021 as a planned inspection, in Snow Hill.

In all, OSHA issued 52 citation items: 31 serious and 21 other-than-serious.

The proposed penalties came to $35,850; today they stand at $19,679, 45% less.

The rule cited most here is 1910.1200 (hazard communication), 6 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $4,500 penalty. Millville Lumber Co., Inc. averages $3,140 across 2 cited inspections.

Millville Lumber Co., Inc.: OSHA citation items per year, 1994 to 2021
Citation items per year, by inspection date.

Maryland · latest 90 days of OSHA records

185employers cited

Get notified the morning OSHA posts each new citation in Maryland: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Maryland

Checking a subcontractor, a client or your own company? Watch Millville Lumber Co., Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345209001 OPENED MAR 22, 2021Closed

Planned · Complete · Safety · 40 employees at the site · Closed Oct 21, 2021

6781 Snow Hill Road, Snow Hill, MD 21863 · Sawmills · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(1) · Machine guarding
Serious$1,400$700Sep 16, 2021Final
Citation 1, item 2 Serious$1,600$800Sep 16, 2021Final
Citation 1, item 3
29 CFR 1910.303(g)(2)(i) · Electrical equipment, general requirements
Serious$600$360Sep 16, 2021Final
Citation 2, item 1
29 CFR 1910.215(a)(4) · Grinders and abrasive wheels
Other-than-serious$0$0Sep 16, 2021Final
Citation 2, item 2
29 CFR 1910.303(e)(1)(ii) · Electrical equipment, general requirements
Other-than-serious$0$0Sep 16, 2021Final
Citation 2, item 3
29 CFR 1910.303(f)(2) · Electrical equipment, general requirements
Other-than-serious$0$0Sep 16, 2021Final
Citation 2, item 4
29 CFR 1910.305(g)(1)(iv)(a) · Electrical wiring methods
Other-than-serious$0$0Sep 16, 2021Final
Citation 2, item 5
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Other-than-serious$0$0Sep 16, 2021Final
Citation 2, item 6
29 CFR 05-503(C)(1)(I)
Other-than-serious$0$0Sep 16, 2021Final

Inspection 345218648 OPENED MAR 22, 2021Closed

Planned · Complete · Health · 40 employees at the site · Closed Dec 29, 2021

6781 Snow Hill Road, Snow Hill, MD 21863 · Sawmills · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.22(a)(1) · Walking-working surfaces
Serious$1,250$713Sep 22, 2021Final
Citation 1, item 2 Serious$1,750$998Sep 22, 2021Final
Citation 1, item 3a
29 CFR 1910.132(a) · Personal protective equipment, general requirements
Serious$1,250$831Sep 22, 2021Final
Citation 1, item 3b
29 CFR 1910.133(a)(1) · Eye and face protection
Serious$0$0Sep 22, 2021Final
Citation 1, item 4
29 CFR 1910.151(c) · First aid and eyewash
Serious$1,250$713Sep 22, 2021Final
Citation 1, item 5a
29 CFR 1910.1200(e)(1) · Hazard communication
Serious$1,750$1,164Sep 22, 2021Final
Citation 1, item 5b
29 CFR 1910.1200(h)(1) · Hazard communication
Serious$0$0Sep 22, 2021Final

Inspection 312737182 OPENED NOV 17, 2008Closed

Planned · Complete · Safety · 40 employees at the site · Closed Jan 26, 2009

6781 Snow Hill Road, Snow Hill, MD 21863 · Cut Stock, Resawing Lumber, and Planing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.37(b)(1) · Exit routes
Serious$2,200$1,453Dec 11, 2008Closed
Citation 1, item 1b
29 CFR 1910.37(b)(2) · Exit routes
Serious$0$0Dec 11, 2008Closed
Citation 1, item 2
29 CFR 1910.110(b)(6)(vi) · Storage and handling of liquefied petroleum gases
Serious$1,925$1,177Dec 11, 2008Closed
Citation 1, item 3a
29 CFR 1910.147(c)(4)(i) · Lockout/tagout
Serious$2,200$1,451Dec 11, 2008Closed
Citation 1, item 3b
29 CFR 1910.147(f)(3)(iid) · Lockout/tagout
Serious$0$0Dec 11, 2008Closed
Citation 1, item 4a
29 CFR 1910.178(l)(4)(iii) · Forklifts and other powered industrial trucks
Serious$2,200$1,450Dec 11, 2008Closed
Citation 1, item 4b
29 CFR 1910.178(p)(1) · Forklifts and other powered industrial trucks
Serious$0$0Dec 11, 2008Closed
Citation 1, item 4c
29 CFR 1910.178(q)(7) · Forklifts and other powered industrial trucks
Serious$0$0Dec 11, 2008Closed
Citation 1, item 5
29 CFR 1910.212(a)(1) · Machine guarding
Serious$1,925$1,179Dec 11, 2008Closed
Citation 1, item 6
29 CFR 1910.212(a)(2) · Machine guarding
Serious$1,650$903Dec 11, 2008Closed
Citation 1, item 7
29 CFR 1910.219(c)(2)(i) · Belts, pulleys and power-transmission parts
Serious$1,650$902Dec 11, 2008Closed
Citation 1, item 8
29 CFR 1910.219(c)(4)(ii) · Belts, pulleys and power-transmission parts
Serious$1,375$626Dec 11, 2008Closed
Citation 1, item 9a
29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts
Serious$1,650$904Dec 11, 2008Closed
Citation 1, item 9b
29 CFR 1910.219(e)(1)(i) · Belts, pulleys and power-transmission parts
Serious$0$0Dec 11, 2008Closed
Citation 1, item 10
29 CFR 1910.219(f)(3) · Belts, pulleys and power-transmission parts
Serious$1,650$900Dec 11, 2008Closed
Citation 1, item 11
29 CFR 50104 A
Serious$2,200$1,455Dec 11, 2008Closed
Citation 2, item 1
29 CFR 1910.22(d)(1) · General requirements
Other-than-serious$0$0Dec 11, 2008Closed
Citation 2, item 2
29 CFR 1910.23(c)(1) · Guarding floor and wall openings and holes
Other-than-serious$0$0Dec 11, 2008Closed
Citation 2, item 3
29 CFR 1910.24(h) · Fixed industrial stairs
Other-than-serious$0$0Dec 11, 2008Closed
Citation 2, item 4
29 CFR 1910.132(d)(2) · Personal protective equipment, general requirements
Other-than-serious$0$0Dec 11, 2008Closed
Citation 2, item 5
29 CFR 1910.147(c)(6)(i) · Lockout/tagout
Other-than-serious$0$0Dec 11, 2008Closed
Citation 2, item 6
29 CFR 1910.147(c)(6)(ii) · Lockout/tagout
Other-than-serious$0$0Dec 11, 2008Closed
Citation 2, item 7
29 CFR 1910.242(b) · Hand and power tools
Other-than-serious$0$0Dec 11, 2008Closed
Citation 2, item 8
29 CFR 1910.305(g)(1)(iv) · Electrical wiring methods
Other-than-serious$0$0Dec 11, 2008Closed
Citation 2, item 9
29 CFR 1910.1200(e)(1) · Hazard communication
Other-than-serious$0$0Dec 11, 2008Closed
Citation 2, item 10
29 CFR 1910.1200(f)(5)(i) · Hazard communication
Other-than-serious$0$0Dec 11, 2008Closed
Citation 2, item 11
29 CFR 1910.1200(f)(5)(ii) · Hazard communication
Other-than-serious$0$0Dec 11, 2008Closed
Citation 2, item 12
29 CFR 1910.1200(h)(1) · Hazard communication
Other-than-serious$0$0Dec 11, 2008Closed
Citation 2, item 13
29 CFR 50405 B03
Other-than-serious$0$0Dec 11, 2008Closed
Citation 2, item 14
29 CFR 50406 A01
Other-than-serious$0$0Dec 11, 2008Closed
Citation 2, item 15 Other-than-serious$0$0Dec 11, 2008Closed

Inspection 119552891 OPENED FEB 4, 1994Closed

Planned · Complete · Safety · 29 employees at the site · Closed Apr 26, 1994

6781 Snow Hill Road, Snow Hill, MD 21863 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.106(b)(2)(viia) · Flammable liquids
Serious$1,225$225Mar 24, 1994Closed
Citation 1, item 2
29 CFR 1910.106(g)(3)(ivd) · Flammable liquids
Serious$1,225$225Mar 24, 1994Closed
Citation 2, item 1
29 CFR 1910.178(l) · Forklifts and other powered industrial trucks
Serious$1,225$350Mar 24, 1994Closed
Citation 2, item 2
29 CFR 1910.178(m)(3) · Forklifts and other powered industrial trucks
Serious$0$0Mar 24, 1994Closed
Citation 3, item 1
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Serious$700$200Mar 24, 1994Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 0912.3302

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(b)(2)(viia)

(vi) Vent piping for aboveground tanks. (a) Vent piping shall be constructed in accordance with paragraph (c) of this section.

29 CFR 1910.106(g)(3)(ivd)

(iv) Dispensing units. (a) Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), shall be transferred from tanks by means of fixed pumps so designed and equipped as to allow control of the flow and to prevent leakage or accidental discharge.

29 CFR 1910.110 · Storage and handling of liquefied petroleum gases

29 CFR 1910.110(b)(6)(vi)

(vi) Readily ignitible material such as weeds and long dry grass shall be removed within 10 feet of any container.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.133 · Eye and face protection

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.151 · First aid and eyewash

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.212 · Machine guarding

29 CFR 1910.215 · Grinders and abrasive wheels

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.22 · Walking-working surfaces

29 CFR 1910.23 · Guarding floor and wall openings and holes

29 CFR 1910.24 · Fixed industrial stairs

29 CFR 1910.242 · Hand and power tools

29 CFR 1910.265 · Sawmills

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.37 · Exit routes

29 CFR 1910.95 · Noise

Other sawmills employers in Maryland

Alert subscribers get notified of each newly cited employer in Maryland the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.