OSHA SearchOSHA records by employer

Model Finishing Co., Inc.: OSHA inspections and violations

Philadelphia, Pennsylvania · Metal Coating, Engraving (except Jewelry and Silverware), and Allied Services to Manufacturers · NAICS 332812

1inspections
8citation items
$5,116current penalties
Sep 28, 2018last inspection

OSHA has inspected Model Finishing Co., Inc. once in Pennsylvania.

The inspection began on Sep 28, 2018 after a complaint, in Philadelphia.

That inspection ended with 8 citation items: 7 serious and 1 other-than-serious.

Penalties were first proposed at $8,526 and now stand at $5,116, 40% lower after settlements or reviews.

Respiratory protection comes up most often in these citations: 3 items under 1910.134.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and Model Finishing Co., Inc. averages $5,116 (1 cited inspection).

Model Finishing Co., Inc.: OSHA citation items per year, 2018 to 2018
Citation items per year, by inspection date.

Pennsylvania · latest 90 days of OSHA records

277employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in Pennsylvania: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Pennsylvania

Checking a subcontractor, a client or your own company? Watch Model Finishing Co., Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343498168 OPENED SEP 28, 2018Closed

Complaint · Complete · Health · 10 employees at the site · Closed Sep 30, 2022

4949 Cottman Ave, Philadelphia, PA 19135 · Metal Coating, Engraving (except Jewelry and Silverware), and Allied Services to Manufacturers · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.107(b)(5)(i) · Spray painting and finishing
Serious$2,842$1,705Mar 12, 2019Final
Citation 1, item 1b
29 CFR 1910.107(f)(3) · Spray painting and finishing
Serious$0$0Mar 12, 2019Final
Citation 1, item 2a
29 CFR 1910.134(c)(2)(ii) · Respiratory protection
Serious$2,842$1,705Mar 12, 2019Final
Citation 1, item 2b
29 CFR 1910.134(e)(1) · Respiratory protection
Serious$0$0Mar 12, 2019Final
Citation 1, item 2c
29 CFR 1910.134(f)(1) · Respiratory protection
Serious$0$0Mar 12, 2019Final
Citation 1, item 3a
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Serious$2,842$1,705Mar 12, 2019Final
Citation 1, item 3b
29 CFR 1910.307(c) · Hazardous (classified) locations
Serious$0$0Mar 12, 2019Final
Citation 2, item 1
29 CFR 1910.305(a)(2)(i)(b) · Electrical wiring methods
Other-than-serious$0$0Mar 12, 2019Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.107(b)(5)(i)

(i) The spraying operations except electrostatic spraying operations shall be so designed, installed and maintained that the average air velocity over the open face of the booth (or booth cross section during spraying operations) shall be not less than 100 linear feet per minute. Electrostatic spraying operations may be conducted with an air velocity over the open face of the booth of not less than 60 linear feet per minute, or more, depending on the volume of the finishing material being applied and its flammability and explosion characteristics. Visible gauges or audible alarm or pressure activated devices shall be installed to indicate or insure that the required air velocity is maintained. Filter rolls shall be inspected to insure proper replacement of filter media.

29 CFR 1910.107(f)(3)

(3) Cleaning of heads. Sprinklers protecting spraying areas shall be kept as free from deposits as practical by cleaning daily if necessary. (See also paragraph (g) of this section.)

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.134(c)(2)(ii)

(ii) In addition, the employer must establish and implement those elements of a written respiratory protection program necessary to ensure that any employee using a respirator voluntarily is medically able to use that respirator, and that the respirator is cleaned, stored, and maintained so that its use does not present a health hazard to the user. Exception: Employers are not required to include in a written respiratory protection program those employees whose only use of respirators involves the voluntary use of filtering facepieces (dust masks).

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.307 · Hazardous (classified) locations

Other metal coating, engraving (except jewelry and silverware), and allied services to manufacturers employers in Pennsylvania

Alert subscribers get notified of each newly cited employer in Pennsylvania the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.