OSHA SearchOSHA records by employer

Mogoo Inc.: OSHA inspections and violations

Washington, District of Columbia · Masonry Contractors · NAICS 238140

6inspections
16citation items
$18,469current penalties
Aug 20, 2019last inspection

Since 2004, OSHA inspectors have visited Mogoo Inc. in District of Columbia 6 times.

The most recent inspection opened on Aug 20, 2019 on a referral, in Washington.

In all, OSHA issued 16 citation items: 12 serious, 2 repeat and 2 other-than-serious.

The proposed penalties came to $20,669; today they stand at $18,469, 11% less.

The rule cited most here is 1926.451 (scaffolds, general requirements), 5 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Mogoo Inc. averages $6,169 across 1 cited inspection.

Mogoo Inc.: OSHA citation items per year, 2004 to 2019
Citation items per year, by inspection date.

Want to know if OSHA cites Mogoo Inc. again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 344250162 OPENED AUG 20, 2019Closed

Referral · Complete · Safety · 20 employees at the site · Closed Feb 14, 2024

3558 11th Street Nw, Washington, DC 20017 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Incident on Aug 20, 2019: Employee receives multiple injuries when brick wall collapse

At 9:30 a.m. on August 20, 2019, an employee worked to under pin a brick wall when the wall collapsed and fell on top of and buried the employee. The employee was hospitalized to treat a fracture to the left femur, dislocated fingers on both hands, lacerations, and strains.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.651(i)(1) · Excavations
Serious$5,398$5,398Feb 14, 2020Final
Citation 1, item 1b
29 CFR 1926.652(a)(1) · Trench protection
Serious$0$0Feb 14, 2020Final
Citation 1, item 1c
29 CFR 1926.651(k)(1) · Excavations
Serious$0$0Feb 14, 2020Final
Citation 2, item 1
29 CFR 1904.40(a) · Giving injury records to OSHA
Other-than-serious$771$771Feb 14, 2020Final

Inspection 339277642 OPENED AUG 7, 2013Closed

Planned · Complete · Safety · 8 employees at the site · Closed Aug 30, 2013

2142 O Street, Nw, Washington, DC 20026 · Other Foundation, Structure, and Building Exterior Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 339075616 OPENED MAY 17, 2013Closed

Referral · Complete · Health · 7 employees at the site · Closed Aug 30, 2013

1108 G Street Ne, Washington, DC 20001 · New Single-Family Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.134(c)(2)(i) · Respiratory protection
Other-than-serious$0$0Jun 20, 2013Final

Inspection 309898104 OPENED MAR 30, 2006Closed

Referral · Complete · Safety · 6 employees at the site · Closed Nov 9, 2006

2412 17st, Nw, Washington, DC 20009 · Site Preparation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.100(a) · Hard hats in construction
Serious$600$250Apr 5, 2006Closed
Citation 1, item 2
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$600$250Apr 5, 2006Closed
Citation 1, item 3a
29 CFR 1926.651(c)(2) · Excavations
Serious$2,000$500Apr 5, 2006Closed
Citation 1, item 3b
29 CFR 1926.652(a)(1) · Trench protection
Serious$0$0Apr 5, 2006Closed

Inspection 308762657 OPENED JUN 2, 2005Closed

Referral · Complete · Safety · 8 employees at the site · Closed Oct 14, 2009

800 3rd Street, Ne, Washington, DC 20002 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.95(a) · Criteria for personal protective equipment
Serious$1,400$1,400Jun 7, 2005Closed
Citation 1, item 2
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$1,000$1,000Jun 7, 2005Closed
Citation 1, item 3
29 CFR 1926.1051(a) · Stairways and Ladders: general requirements
Serious$600$600Jun 7, 2005Closed
Citation 2, item 1
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Repeat$4,000$4,000Jun 7, 2005Closed
Citation 2, item 2
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Repeat$4,000$4,000Jun 7, 2005Closed

Inspection 308268481 OPENED DEC 9, 2004Closed

Referral · Complete · Safety · 4 employees at the site · Closed Jan 25, 2005

1430 5th Street, Nw, Washington, DC 20001 · Residential Remodelers · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$300$300Dec 16, 2004Closed
Citation 1, item 1b
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$0$0Dec 16, 2004Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1904.40 · Giving injury records to OSHA

29 CFR 1904.40(a)

(a) Basic requirement. When an authorized government representative asks for the records you keep under part 1904, you must provide copies of the records within four (4) business hours.

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.134(c)(2)(i)

(i) An employer may provide respirators at the request of employees or permit employees to use their own respirators, if the employer determines that such respirator use will not in itself create a hazard. If the employer determines that any voluntary respirator use is permissible, the employer shall provide the respirator users with the information contained in appendix D to this section (“Information for Employees Using Respirators When Not Required Under the Standard”); and

29 CFR 1926.100 · Hard hats in construction

29 CFR 1926.100(a)

(a) Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, shall be protected by protective helmets.

29 CFR 1926.1051 · Stairways and Ladders: general requirements

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.651 · Excavations

29 CFR 1926.652 · Trench protection

29 CFR 1926.95 · Criteria for personal protective equipment

Other masonry contractors employers in District of Columbia

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.