Monogram Prepared Meats: OSHA inspections and violations
Harlan, Iowa · Meat Processed from Carcasses · NAICS 311612
4inspections
8citation items
$56,593current penalties
May 25, 2022last inspection
Since 2015, OSHA inspectors have visited Monogram Prepared Meats in Iowa 4 times.
The most recent inspection opened on May 25, 2022 on a referral, in Harlan.
In all, OSHA issued 8 citation items: 7 serious and 1 other-than-serious.
The proposed penalties came to $77,879; today they stand at $56,593, 27% less.
The rule cited most here is 1910.333 (working near live electrical parts), 3 times.
Among manufacturing employers, the typical cited inspection since 2015 ends with a $4,875 penalty. Monogram Prepared Meats averages $18,864 across 3 cited inspections.
Monogram Prepared Meats also files yearly injury logs with OSHA, summarized below.
Citation items per year, by inspection date.
Iowa · latest 90 days of OSHA records
69employers cited
Get notified the morning OSHA posts each new citation in Iowa: the employer, the site address, the rules broken and the penalty.
Incident on Apr 6, 2020: Employee working in power supply cabinet receives shock
At 7:30 p.m. on April 6, 2020, an employee was working for a firm that prepared meat from carcasses. He was the maintenance supervisor. He was working in the firm's upstairs transmitter room. The narrative said the equipment being worked on was microwave equipment, but that was not correct. The power was being generated in the ultrasound region, at 73 kHz, as a form of non-thermal food-processing technology. The employee was troubleshooting inside the transmitter's electrical cabinet. Parts within were energized at a variety of voltages. The electrical cabinet was supplied with three-phase 480-volt AC power, and some parts inside were energized at that level. The cabinet also contained parts energized at DC voltages from 12 volts DC to 18,000 volts DC. Finally, the 73 kHz ultrasound power was present inside the cabinet. The employee was using a Klein Tools CL1000 clamp-on multimeter. To keep from disrupting production, the employee had not electrically locked out the cabinet. He was relying on the door interlock to keep the power from coming on. The electrical interlocks on the cabinet had been disabled, however, so that videos could be made of arcing inside the cabinet. They had never been restored to a functioning condition. The employee was attaching the meter to check for amperage, unaware that someone on the line downstairs had hit the start button, energizing parts inside the cabinet. The employee's left elbow and right forearm made direct contact with energized parts. He received an electric shock and burns to his left elbow and right forearm. A coworker found him lying on the floor. CPR was initiated, and emergency services were called. The employee was life flighted for treatment. He was hospitalized. The employee had not received training in safe electrical work practices, working alone, the use of PPE such as rubber insulated gloves or arc flash protection, grounding, or lockout/tagout. The equipment had been scheduled for replacement since December 2019.
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2024, the Harlan site logged 4 recordable injuries or illnesses among about 325 workers: 1.2 per 100 full-time workers, against a median of 3.7 for its industry. Those cases cost 17 days away from work.
Site and year
Workers
Cases
Days-away cases
Rate
Industry median
Monogram Prepared Meats LLC
Harlan · 2024
325
4
1
1.2
3.7
Monogram Prepared Meats, LLC
Harlan · 2023
303
8
4
2.4
3.7
Monogram Prepared Meats
Harlan · 2018
270
8
4
2.9
3.7
Included with any plan: 5 more yearly logs from these sites, back to 2016, with each site's average rate over its latest three years. Already a subscriber? Sign in.
(a) Basic requirement. When an authorized government representative asks for the records you keep under part 1904, you must provide copies of the records within four (4) business hours.
(4) Energy control procedure. (i) Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section.
29 CFR 1910.219 · Belts, pulleys and power-transmission parts
29 CFR 1910.219(f)(3)
(3) Sprockets and chains. All sprocket wheels and chains shall be enclosed unless they are more than seven (7) feet above the floor or platform. Where the drive extends over other machine or working areas, protection against falling shall be provided. This subparagraph does not apply to manually operated sprockets.
Alert subscribers get notified of each newly cited employer in Iowa the morning it is posted. See the alert plans.