Inspection 341127736 OPENED DEC 7, 2015Closed
Melva Lane, Williamstown, NJ 08094 · Sewage Treatment Facilities · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Williamstown, New Jersey · Sewage Treatment Facilities · NAICS 221320
OSHA has inspected Monroe M.U.A. Operations 2 times in New Jersey since 2015.
The latest one began on Dec 7, 2015 to follow up on an earlier case, in Williamstown.
Those inspections ended with 19 citation items: 12 serious and 7 other-than-serious.
Penalties were first proposed at $42,000 and still stand at $42,000.
Lockout/tagout comes up most often in these citations: 3 items under 1910.147.
How that compares: the median penalty per cited inspection for utility employers since 2015 is $0, and Monroe M.U.A. Operations averages $42,000 (1 cited inspection).
New Jersey · latest 90 days of OSHA records
269employers cited
7 of them in the same industry
Get notified the morning OSHA posts each new citation in New Jersey: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in New Jersey
Checking a subcontractor, a client or your own company? Watch Monroe M.U.A. Operations and get notified the morning OSHA posts a new citation for it.
Watch this companyMelva Lane, Williamstown, NJ 08094 · Sewage Treatment Facilities · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Melva Lane, Williamstown, NJ 08094 · Sewage Treatment Facilities · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.22(a)(1) · General requirements |
Serious | $2,800 | $2,800 | Nov 5, 2015 | Final |
| Citation 1, item 2 29 CFR 1910.23(a)(1) · Guarding floor and wall openings and holes |
Serious | $2,800 | $2,800 | Nov 5, 2015 | Final |
| Citation 1, item 3 29 CFR 1910.37(a)(3) · Exit routes |
Serious | $2,800 | $2,800 | Nov 5, 2015 | Final |
| Citation 1, item 4 29 CFR 1910.106(d)(3)(ii)(a) · Flammable liquids |
Serious | $3,500 | $3,500 | Nov 5, 2015 | Final |
| Citation 1, item 5 29 CFR 1910.125(e)(5) · Additional requirements for dipping and coating operations that use flammable liquids or liquids with flashpoints greater than 199.4 °F (93 °C) |
Serious | $3,500 | $3,500 | Nov 5, 2015 | Final |
| Citation 1, item 6 29 CFR 1910.146(k)(1)(i) · Permit-required confined spaces |
Serious | $3,500 | $3,500 | Nov 5, 2015 | Final |
| Citation 1, item 7 29 CFR 1910.212(b) · Machine guarding |
Serious | $2,800 | $2,800 | Nov 5, 2015 | Final |
| Citation 1, item 8 29 CFR 1910.304(f)(1)(iv) · Grounding and circuit protection |
Serious | $2,800 | $2,800 | Nov 5, 2015 | Final |
| Citation 1, item 9 29 CFR 1910.305(a)(2)(i) · Electrical wiring methods |
Serious | $2,800 | $2,800 | Nov 5, 2015 | Final |
| Citation 1, item 10 29 CFR 1910.305(b)(1)(ii) · Electrical wiring methods |
Serious | $3,500 | $3,500 | Nov 5, 2015 | Final |
| Citation 1, item 11 29 CFR 1910.334(a)(3)(ii) · Using electrical equipment |
Serious | $3,500 | $3,500 | Nov 5, 2015 | Final |
| Citation 1, item 12 29 CFR N.J.S.A. 34:6A-33(A) |
Serious | $2,800 | $2,800 | Nov 5, 2015 | Final |
| Citation 2, item 1 29 CFR 1910.146(g)(1) · Permit-required confined spaces |
Other-than-serious | $700 | $700 | Nov 5, 2015 | Final |
| Citation 2, item 2 29 CFR 1910.146(k)(2)(iv) · Permit-required confined spaces |
Other-than-serious | $700 | $700 | Nov 5, 2015 | Final |
| Citation 2, item 3 29 CFR 1910.147(c)(4)(ii) · Lockout/tagout |
Other-than-serious | $700 | $700 | Nov 5, 2015 | Final |
| Citation 2, item 4 29 CFR 1910.147(c)(6)(i) · Lockout/tagout |
Other-than-serious | $700 | $700 | Nov 5, 2015 | Final |
| Citation 2, item 5 29 CFR 1910.147(c)(7)(iv) · Lockout/tagout |
Other-than-serious | $700 | $700 | Nov 5, 2015 | Final |
| Citation 2, item 6 29 CFR 1910.178(l)(1)(i) · Forklifts and other powered industrial trucks |
Other-than-serious | $700 | $700 | Nov 5, 2015 | Final |
| Citation 2, item 7 29 CFR 1910.303(f)(2) · Electrical equipment, general requirements |
Other-than-serious | $700 | $700 | Nov 5, 2015 | Final |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.106(d)(3)(ii)(a)
(ii) Fire resistance. Storage cabinets shall be designed and constructed to limit the internal temperature to not more than 325 °F. when subjected to a 10-minute fire test using the standard time-temperature curve as set forth in Standard Methods of Fire Tests of Building Construction and Materials, NFPA 251-1969, which is incorporated by reference as specified in § 1910.6. All joints and seams shall remain tight and the door shall remain securely closed during the fire test. Cabinets shall be labeled in conspicuous lettering, “Flammable—Keep Fire Away.”
29 CFR 1910.125(e)(5)
(5) You must prohibit smoking in a vapor area and must post a readily visible “No Smoking” sign near each dip tank.
29 CFR 1910.146(g)(1)
(g) Training. (1) The employer shall provide training so that all employees whose work is regulated by this section acquire the understanding, knowledge, and skills necessary for the safe performance of the duties assigned under this section.
Alert subscribers get notified of each newly cited employer in New Jersey the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.