OSHA SearchOSHA records by employer

Montague Development, LLC: OSHA inspections and violations

Sanford, North Carolina · Water and Sewer Line and Related Structures Construction · NAICS 237110

2inspections
3citation items
$2,000current penalties
Jul 27, 2018last inspection

OSHA has inspected Montague Development, LLC 2 times in North Carolina since 2007.

The latest one began on Jul 27, 2018 as a planned inspection, in Clayton.

Those inspections ended with 3 citation items: 1 serious and 2 other-than-serious.

Penalties were first proposed at $2,000 and still stand at $2,000.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Montague Development, LLC averages $2,000 (1 cited inspection).

Montague Development, LLC: OSHA citation items per year, 2007 to 2018
Citation items per year, by inspection date.

Want to know if OSHA cites Montague Development, LLC again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 343345021 OPENED JUL 27, 2018Closed

Planned · Complete · Safety · 73 employees at the site · Closed Nov 20, 2018

1340 Hwy 42 East, Clayton, NC 27520 · Site Preparation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.602(a)(9)(ii) · Earthmovers and forklifts in construction
Serious$2,000$2,000Aug 30, 2018Final

Inspection 310504188 OPENED FEB 16, 2007Closed

Complaint · Partial · Safety · 5 employees at the site · Closed Apr 5, 2007

500 Gloucester Drive, Sanford, NC 27330 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.652(c)(2)(iii) · Trench protection
Other-than-serious$0$0Mar 7, 2007Closed
Citation 1, item 2
29 CFR 1926.1053(b)(16) · Ladders in construction
Other-than-serious$0$0Mar 7, 2007Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(16)

(16) Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, shall either be immediately marked in a manner that readily identifies them as defective, or be tagged with “Do Not Use” or similar language, and shall be withdrawn from service until repaired.

29 CFR 1926.602 · Earthmovers and forklifts in construction

29 CFR 1926.602(a)(9)(ii)

(ii) No employer shall permit earthmoving or compacting equipment which has an obstructed view to the rear to be used in reverse gear unless the equipment has in operation a reverse signal alarm distinguishable from the surrounding noise level or an employee signals that it is safe to do so.

29 CFR 1926.652 · Trench protection

29 CFR 1926.652(c)(2)(iii)

(iii) Manufacturer's specifications, recommendations, and limitations, and manufacturer's approval to deviate from the specifications, recommendations, and limitations shall be in written form at the jobsite during construction of the protective system. After that time this data may be stored off the jobsite, but a copy shall be made available to the Secretary upon request.

Other water and sewer line and related structures construction employers in North Carolina

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.