OSHA SearchOSHA records by employer

Morales Contractor, L.L.C.: OSHA inspections and violations

Charleston, West Virginia · Siding Contractors · NAICS 238170

1inspections
8citation items
$18,000current penalties
Jul 8, 2025last inspection

Morales Contractor, L.L.C. has one OSHA inspection on record in West Virginia.

OSHA opened it on Jul 8, 2025 as a planned inspection, in Charleston, and the case has not closed yet.

From that inspection OSHA issued 8 citation items: 8 serious.

OSHA proposed $26,102 in penalties. After settlements and reviews the total is $18,000, down 31%.

Most often, OSHA cited 1926.451, scaffolds, general requirements (5 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Morales Contractor, L.L.C. averages $18,000 over 1 cited inspection in that time.

Morales Contractor, L.L.C.: OSHA citation items per year, 2025 to 2025
Citation items per year, by inspection date.

West Virginia · latest 90 days of OSHA records

28employers cited

Get notified the morning OSHA posts each new citation in West Virginia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in West Virginia

Checking a subcontractor, a client or your own company? Watch Morales Contractor, L.L.C. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348358219 OPENED JUL 8, 2025Open

Planned · Partial · Safety · 7 employees at the site · Open

600 Shrewsbury Street Covenant House, Charleston, WV 25301 · Siding Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$3,972$3,500Jan 8, 2026Final
Citation 1, item 2
29 CFR 1926.451(b)(5)(ii) · Scaffolds, general requirements
Serious$2,838$2,500Jan 8, 2026Final
Citation 1, item 3
29 CFR 1926.451(b)(10) · Scaffolds, general requirements
Serious$3,972$1,500Jan 8, 2026Final
Citation 1, item 4
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Serious$3,972$1,500Jan 8, 2026Final
Citation 1, item 5
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$3,972$3,500Jan 8, 2026Final
Citation 1, item 6
29 CFR 1926.452(j)(2) · Rules for each type of scaffold
Serious$3,972$2,500Jan 8, 2026Final
Citation 1, item 7
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$1,702$1,500Jan 8, 2026Final
Citation 1, item 8
29 CFR 1926.1053(b)(13) · Ladders in construction
Serious$1,702$1,500Jan 8, 2026Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(13)

(13) The top or top step of a stepladder shall not be used as a step.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)

(b) Scaffold platform construction. (1) Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows:

29 CFR 1926.451(b)(10)

(10) Scaffold components manufactured by different manufacturers shall not be intermixed unless the components fit together without force and the scaffold's structural integrity is maintained by the user. Scaffold components manufactured by different manufacturers shall not be modified in order to intermix them unless a competent person determines the resulting scaffold is structurally sound.

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.501 · Fall protection in construction

Other siding contractors employers in West Virginia

Alert subscribers get notified of each newly cited employer in West Virginia the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.