Inspection 345921852 OPENED APR 26, 2022Closed
4665 Winstead Road, Meridian, MS 39307 · Wood Kitchen Cabinet and Countertop Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Meridian, Mississippi · Wood Kitchen Cabinet and Countertop Manufacturing · NAICS 337110
OSHA has inspected Mowdy Cabinetry LLC 3 times in Mississippi since 2021.
The latest one began on Apr 26, 2022 to follow up on an earlier case, in Meridian.
Those inspections ended with 12 citation items: 10 serious and 2 other-than-serious.
Penalties were first proposed at $11,189 and now stand at $6,713, 40% lower after settlements or reviews.
Respiratory protection comes up most often in these citations: 4 items under 1910.134.
How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and Mowdy Cabinetry LLC averages $3,357 (2 cited inspections).
Mississippi · latest 90 days of OSHA records
15employers cited
Get notified the morning OSHA posts each new citation in Mississippi: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Mississippi
Checking a subcontractor, a client or your own company? Watch Mowdy Cabinetry LLC and get notified the morning OSHA posts a new citation for it.
Watch this company4665 Winstead Road, Meridian, MS 39307 · Wood Kitchen Cabinet and Countertop Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
4665 Winstead Road, Meridian, MS 39307 · Wood Kitchen Cabinet and Countertop Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 OSH Act Section 5(a)(1) · General Duty Clause |
Serious | $3,729 | $2,237 | Jan 26, 2022 | Final |
| Citation 1, item 2 29 CFR 1910.305(j)(1)(i) · Electrical wiring methods |
Serious | $1,865 | $1,119 | Jan 26, 2022 | Final |
| Citation 2, item 1 29 CFR 1910.22(a)(1) · Walking-working surfaces |
Other-than-serious | $0 | $0 | Jan 26, 2022 | Final |
| Citation 2, item 2 29 CFR 1910.303(b)(2) · Electrical equipment, general requirements |
Other-than-serious | $0 | $0 | Jan 26, 2022 | Final |
4665 Winstead Road, Meridian, MS 39307 · Wood Kitchen Cabinet and Countertop Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1910.134(c)(1) · Respiratory protection |
Serious | $1,865 | $1,119 | Jan 26, 2022 | Final |
| Citation 1, item 1b 29 CFR 1910.134(e)(1) · Respiratory protection |
Serious | $0 | $0 | Jan 26, 2022 | Final |
| Citation 1, item 1c 29 CFR 1910.134(f)(2) · Respiratory protection |
Serious | $0 | $0 | Jan 26, 2022 | Final |
| Citation 1, item 1d 29 CFR 1910.134(k) · Respiratory protection |
Serious | $0 | $0 | Jan 26, 2022 | Final |
| Citation 1, item 2a 29 CFR 1910.106(e)(2)(iv)(d) · Flammable liquids |
Serious | $1,865 | $1,119 | Jan 26, 2022 | Final |
| Citation 1, item 2b 29 CFR 1910.106(e)(6)(ii) · Flammable liquids |
Serious | $0 | $0 | Jan 26, 2022 | Final |
| Citation 1, item 3a 29 CFR 1910.1200(e)(1) · Hazard communication |
Serious | $1,865 | $1,119 | Jan 26, 2022 | Final |
| Citation 1, item 3b 29 CFR 1910.1200(h)(1) · Hazard communication |
Serious | $0 | $0 | Jan 26, 2022 | Final |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.106(e)(2)(iv)(d)
(iv) Handling liquids at point of final use. (a) Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), shall be kept in covered containers when not actually in use.
29 CFR 1910.106(e)(6)(ii)
(ii) Grounding. Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), shall not be dispensed into containers unless the nozzle and container are electrically interconnected. Where the metallic floorplate on which the container stands while filling is electrically connected to the fill stem or where the fill stem is bonded to the container during filling operations by means of a bond wire, the provisions of this section shall be deemed to have been complied with.
29 CFR 1910.1200(e)(1)
(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:
Alert subscribers get notified of each newly cited employer in Mississippi the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.