OSHA SearchOSHA records by employer

MPL Company: OSHA inspections and violations

Fairland, Indiana · Cut Stone and Stone Product Manufacturing · NAICS 327991

5inspections
64citation items
$7,895current penalties
Dec 10, 2018last inspection

Since 1996, OSHA inspectors have visited MPL Company in Indiana 5 times.

The most recent inspection opened on Dec 10, 2018 on a referral, in Fairland.

In all, OSHA issued 64 citation items: 50 serious and 14 other-than-serious.

The proposed penalties came to $40,500; today they stand at $7,895, 81% less.

The rule cited most here is 1910.106 (flammable liquids), 17 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $4,500 penalty. MPL Company averages $2,750 across 2 cited inspections.

MPL Company also files yearly injury logs with OSHA, summarized below.

MPL Company: OSHA citation items per year, 1996 to 2018
Citation items per year, by inspection date.

Indiana · latest 90 days of OSHA records

78employers cited

Get notified the morning OSHA posts each new citation in Indiana: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Indiana

Checking a subcontractor, a client or your own company? Watch MPL Company and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343649463 OPENED DEC 10, 2018Closed

Referral · Partial · Safety · 120 employees at the site · Closed May 24, 2019

203 North Edgerton Street, Fairland, IN 46126 · All Other Plastics Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.147(c)(4)(i) · Lockout/tagout
Serious$4,000$2,000Feb 15, 2019Final
Citation 1, item 1b
29 CFR 1910.147(c)(7)(i)(a) · Lockout/tagout
Serious$0$0Feb 15, 2019Final

Inspection 342825437 OPENED NOV 17, 2017Closed

Referral · Partial · Safety · 113 employees at the site · Closed Jan 23, 2018

203 North Edgerton, Fairland, IN 46126 · Cut Stone and Stone Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.219(f)(3) · Belts, pulleys and power-transmission parts
Serious$3,500$3,500Dec 14, 2017Final

Inspection 300717121 OPENED JUN 8, 2000Closed

Planned · Complete · Safety · 31 employees at the site · Closed Oct 11, 2000

203 North Edgerton, Fairland, IN 46126 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.304(a)(2) · Grounding and circuit protection
Serious$900$335Sep 1, 2000Closed
Citation 1, item 2
29 CFR 1910.305(g)(2)(ii) · Electrical wiring methods
Serious$3,000$560Sep 1, 2000Closed
Citation 2, item 1
29 CFR 1910.107(g)(3) · Spray painting and finishing
Other-than-serious$0$0Sep 1, 2000Closed
Citation 2, item 2
29 CFR 1910.157(c)(1) · Portable fire extinguishers
Other-than-serious$0$0Sep 1, 2000Closed
Citation 2, item 3
29 CFR 1910.157(e)(3) · Portable fire extinguishers
Other-than-serious$0$0Sep 1, 2000Closed
Citation 2, item 4
29 CFR 1910.242(b) · Hand and power tools
Other-than-serious$0$0Sep 1, 2000Closed
Citation 2, item 5
29 CFR 1910.304(f)(4) · Grounding and circuit protection
Other-than-serious$0$0Sep 1, 2000Closed
Citation 2, item 6
29 CFR 1910.305(b)(3)(i) · Electrical wiring methods
Other-than-serious$0$0Sep 1, 2000Closed
Citation 2, item 7
29 CFR 1910.305(g)(1)(ii) · Electrical wiring methods
Other-than-serious$0$0Sep 1, 2000Closed

Inspection 114957608 OPENED OCT 29, 1997Closed

Complaint · Partial · Health · 22 employees at the site · Closed Jan 3, 2005

203 North Edgerton, Fairland, IN 46126 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.22(a)(1) · General requirements
Serious$2,100$500Mar 26, 1998Final
Citation 1, item 2a
29 CFR 1910.106(e)(2)(ivb) · Flammable liquids
Serious$2,100$1,000Mar 26, 1998Final
Citation 1, item 2b
29 CFR 1910.106(e)(2)(ivd) · Flammable liquids
Serious$0$0Mar 26, 1998Final
Citation 1, item 2c
29 CFR 1910.106(e)(9)(iii) · Flammable liquids
Serious$0$0Mar 26, 1998Final
Citation 1, item 3
29 CFR 1910.106(e)(2)(iva) · Flammable liquids
Serious$1,200$0Mar 26, 1998Final
Citation 1, item 4
29 CFR 1910.106(e)(6)(i) · Flammable liquids
Serious$1,200$0Mar 26, 1998Final

Inspection 125322024 OPENED MAY 31, 1996Closed

Complaint · Partial · Health · 19 employees at the site · Closed Apr 20, 2006

203 North Edgerton, Fairland, IN 46126 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.23(a)(5) · Guarding floor and wall openings and holes
Serious$1,250$0Oct 31, 1996Final
Citation 1, item 2 Serious$2,500$0Oct 31, 1996Final
Citation 1, item 3a
29 CFR 1910.106(b)(1)(ib) · Flammable liquids
Serious$1,250$0Oct 31, 1996Final
Citation 1, item 3b
29 CFR 1910.106(b)(1)(if) · Flammable liquids
Serious$0$0Oct 31, 1996Final
Citation 1, item 3c
29 CFR 1910.106(b)(1)(iii) · Flammable liquids
Serious$0$0Oct 31, 1996Final
Citation 1, item 3d
29 CFR 1910.106(b)(4)(i) · Flammable liquids
Serious$0$0Oct 31, 1996Final
Citation 1, item 3e
29 CFR 1910.106(b)(4)(iva) · Flammable liquids
Serious$0$0Oct 31, 1996Final
Citation 1, item 3f
29 CFR 1910.106(b)(4)(ivh) · Flammable liquids
Serious$0$0Oct 31, 1996Final
Citation 1, item 3g
29 CFR 1910.106(b)(6) · Flammable liquids
Serious$0$0Oct 31, 1996Final
Citation 1, item 3h
29 CFR 1910.106(b)(7) · Flammable liquids
Serious$0$0Oct 31, 1996Final
Citation 1, item 3i
29 CFR 1910.106(e)(2)(ii) · Flammable liquids
Serious$0$0Oct 31, 1996Final
Citation 1, item 3j
29 CFR 1910.106(e)(2)(iib)(2) · Flammable liquids
Serious$0$0Oct 31, 1996Final
Citation 1, item 3k
29 CFR 1910.106(e)(6)(i) · Flammable liquids
Serious$0$0Oct 31, 1996Final
Citation 1, item 3l
29 CFR 1910.106(e)(6)(ii) · Flammable liquids
Serious$0$0Oct 31, 1996Final
Citation 1, item 4a
29 CFR 1910.108(d) · [Reserved]
Serious$1,250$0Oct 31, 1996Final
Citation 1, item 4b Serious$0$0Oct 31, 1996Final
Citation 1, item 4c
29 CFR 1910.108(f)(1) · [Reserved]
Serious$0$0Oct 31, 1996Final
Citation 1, item 4d
29 CFR 1910.108(f)(2) · [Reserved]
Serious$0$0Oct 31, 1996Final
Citation 1, item 4e
29 CFR 1910.108(f)(3) · [Reserved]
Serious$0$0Oct 31, 1996Final
Citation 1, item 4f
29 CFR 1910.108(f)(4) · [Reserved]
Serious$0$0Oct 31, 1996Final
Citation 1, item 4g Serious$0$0Oct 31, 1996Final
Citation 1, item 4h Serious$0$0Oct 31, 1996Final
Citation 1, item 5a
29 CFR 1910.120(g)(3)(i) · Hazardous waste operations and emergency response
Serious$1,250$0Oct 31, 1996Final
Citation 1, item 5b
29 CFR 1910.120(g)(5) · Hazardous waste operations and emergency response
Serious$0$0Oct 31, 1996Final
Citation 1, item 5c
29 CFR 1910.120(q)(1) · Hazardous waste operations and emergency response
Serious$0$0Oct 31, 1996Final
Citation 1, item 5d
29 CFR 1910.120(q)(6) · Hazardous waste operations and emergency response
Serious$0$0Oct 31, 1996Final
Citation 1, item 5e
29 CFR 1910.120(q)(9)(i) · Hazardous waste operations and emergency response
Serious$0$0Oct 31, 1996Final
Citation 1, item 6a
29 CFR 1910.132(d)(1) · Personal protective equipment, general requirements
Serious$2,500$0Oct 31, 1996Final
Citation 1, item 6b
29 CFR 1910.132(f)(1) · Personal protective equipment, general requirements
Serious$0$0Oct 31, 1996Final
Citation 1, item 7
29 CFR 1910.136(a) · Foot protection
Serious$2,500$0Oct 31, 1996Final
Citation 1, item 9
29 CFR 1910.147(c)(1) · Lockout/tagout
Serious$1,250$0Oct 31, 1996Final
Citation 1, item 10
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$1,250$0Oct 31, 1996Final
Citation 1, item 11
29 CFR 1910.242(b) · Hand and power tools
Serious$1,250$0Oct 31, 1996Final
Citation 1, item 12
29 CFR 1910.254(d)(7) · Arc welding and cutting
Serious$1,250$0Oct 31, 1996Final
Citation 1, item 13
29 CFR 1910.305(g)(1)(iii) · Electrical wiring methods
Serious$1,250$0Oct 31, 1996Final
Citation 1, item 14
29 CFR 1910.1200(e)(1) · Hazard communication
Serious$1,250$0Oct 31, 1996Final
Citation 1, item 15a
29 CFR 1910.1200(f)(5)(i) · Hazard communication
Serious$1,250$0Oct 31, 1996Final
Citation 1, item 15b
29 CFR 1910.1200(f)(5)(ii) · Hazard communication
Serious$0$0Oct 31, 1996Final
Citation 1, item 16
29 CFR 1910.1200(h) · Hazard communication
Serious$1,250$0Oct 31, 1996Final
Citation 2, item 1
29 CFR 4000402
Other-than-serious$0$0Oct 31, 1996Final
Citation 2, item 2
29 CFR 1910.134(b)(10) · Respiratory protection
Other-than-serious$0$0Oct 31, 1996Final
Citation 2, item 3
29 CFR 1910.134(e)(5) · Respiratory protection
Other-than-serious$0$0Oct 31, 1996Final
Citation 2, item 4
29 CFR 1910.134(e)(5)(i) · Respiratory protection
Other-than-serious$0$0Oct 31, 1996Final
Citation 2, item 5
29 CFR 1910.134(f)(1) · Respiratory protection
Other-than-serious$0$0Oct 31, 1996Final
Citation 2, item 6
29 CFR 1910.157(g)(1) · Portable fire extinguishers
Other-than-serious$0$0Oct 31, 1996Final
Citation 2, item 7
29 CFR 1910.176(a) · Material storage and aisles
Other-than-serious$0$0Oct 31, 1996Final

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2016, the Fairland site logged 6 recordable injuries or illnesses among about 105 workers: 285.7 per 100 full-time workers, against a median of 2.6 for its industry. Those cases cost 18 days away from work.

Site and yearWorkersCasesDays-away casesRateIndustry median
MPL Corp
Fairland · 2016
105 61285.72.6

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(b)(1)(ib)

(b) Tank storage—(1) Design and construction of tanks—(i) Materials. (a) Tanks shall be built of steel except as provided in paragraphs (b)(1)(i) (b) through (e) of this section.

29 CFR 1910.106(b)(1)(if)

(b) Tank storage—(1) Design and construction of tanks—(i) Materials. (a) Tanks shall be built of steel except as provided in paragraphs (b)(1)(i) (b) through (e) of this section.

29 CFR 1910.106(b)(1)(iii)

(iii) Atmospheric tanks. (a) Atmospheric tanks shall be built in accordance with acceptable good standards of design. Atmospheric tanks may be built in accordance with the following consensus standards that are incorporated by reference as specified in § 1910.6:

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.108 · [Reserved]

29 CFR 1910.120 · Hazardous waste operations and emergency response

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.136 · Foot protection

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.176 · Material storage and aisles

29 CFR 1910.212 · Machine guarding

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.22 · General requirements

29 CFR 1910.23 · Guarding floor and wall openings and holes

29 CFR 1910.242 · Hand and power tools

29 CFR 1910.254 · Arc welding and cutting

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.95 · Noise

Other cut stone and stone product manufacturing employers in Indiana

Alert subscribers get notified of each newly cited employer in Indiana the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.