OSHA SearchOSHA records by employer

MSH Homes Inc: OSHA inspections and violations

Chesapeake, Virginia · New Single-Family Housing Construction (except For-Sale Builders) · NAICS 236115

2inspections
15citation items
$12,670current penalties
Jan 15, 2016last inspection

OSHA has inspected MSH Homes Inc 2 times in Virginia since 2010.

The latest one began on Jan 15, 2016, in Chesapeake.

Those inspections ended with 15 citation items: 15 serious.

Penalties were first proposed at $8,750 and still stand at $12,670.

Scaffolds, general requirements comes up most often in these citations: 8 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and MSH Homes Inc averages $1,470 (1 cited inspection).

1 inspection on this page followed a fatal incident.

MSH Homes Inc: OSHA citation items per year, 2010 to 2016
Citation items per year, by inspection date.

Virginia · latest 90 days of OSHA records

248employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in Virginia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Virginia

Checking a subcontractor, a client or your own company? Watch MSH Homes Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341182921 OPENED JAN 15, 2016Closed

Unprogrammed other · Partial · Safety · 3 employees at the site · Closed May 18, 2016

3954 Cornland Road, Chesapeake, VA 23322 · New Single-Family Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.20(b)(2) · Construction safety programs
Serious$2,100$1,470Mar 3, 2016Final

Inspection 314716259 OPENED JUL 14, 2010Closed

Accident · Complete · Safety · 5 employees at the site · Closed Apr 25, 2016

1134 Hillwell Road, Chesapeake, VA 23322 · New Single-Family Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Incident on Jul 14, 2010 (fatal): Two employees are injured, one dies when scaffold collapses

On July 14, 2010, Employees #1 and #2 were engaged in the installation and attac hment of roof rafters to the ridge beam in a new construction, two-story residen tial home. Employees #1 and #2 were working from a metal scaffold plank spanning the centerline of the structure in a North to South direction. The metal scaffo ld plank was mounted on four site built double pole wooden scaffolds attached to the second floor, floor joists. The metal scaffold planks spanned an open area below for a distance of 21 ft 4 in. Double pole scaffold framing consisted of ve rtical 2-in by 4-in. by 8-ft nominal wooden framing with 2-ft by 6-in. by 36-in. nominal horizontal bearers. The scaffold framing wooden diagonal bracing was in complete and not in accordance with OSHA standards. Multiple bearer blocks, hori zontal runners, and diagonal bracing across the outside were not installed. All wooden members were joined using three to five 3-in. nails at each connecting po int. At the time of the accident, Employees #1 and #2 were standing on the metal scaffold plank directly over one double pole scaffold frame. One worker was hol ding a rafter in place; the second worker was nailing the rafter to the ridge be am when the double pole scaffold frame directly beneath them failed. The metal s caffold plank fell vertically approximately 7 ft 6 in. landing on the wooden flo or joists while both employees fell to the wooden sub 16 ft 9 in. below. Followi ng the collapse, two coworkers went to the aid of the injured employees and one coworker called for emergency medical service with a cellular phone. Employee #2 received minor injuries to his upper back, while Employee #1received traumatic injuries to the head. Both employees were transported by ambulance to a local tr auma center, where Employee #2 was treated and released. Employee #1 underwent e mergency surgery and died ten days later without regaining consciousness.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 16a
29 CFR 1926.451(a)(6) · Scaffolds, general requirements
Serious$2,800$5,600Nov 30, 2010Final
Citation 1, item 16b
29 CFR 1926.451(b)(2) · Scaffolds, general requirements
Serious$0$0Nov 30, 2010Final
Citation 1, item 16c
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$0$0Nov 30, 2010Final
Citation 1, item 16d
29 CFR 1926.451(f)(1) · Scaffolds, general requirements
Serious$0$0Nov 30, 2010Final
Citation 1, item 16e
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Serious$0$0Nov 30, 2010Final
Citation 1, item 16f
29 CFR 1926.451(f)(4) · Scaffolds, general requirements
Serious$0$0Nov 30, 2010Final
Citation 1, item 16g
29 CFR 1926.451(f)(7) · Scaffolds, general requirements
Serious$0$0Nov 30, 2010Final
Citation 1, item 16h
29 CFR 1926.451(g)(1)(viii) · Scaffolds, general requirements
Serious$0$0Nov 30, 2010Final
Citation 1, item 17a
29 CFR 1926.452(a)(3) · Rules for each type of scaffold
Serious$2,800$5,600Nov 30, 2010Final
Citation 1, item 17b
29 CFR 1926.452(a)(6) · Rules for each type of scaffold
Serious$0$0Nov 30, 2010Final
Citation 1, item 17c
29 CFR 1926.452(a)(7) · Rules for each type of scaffold
Serious$0$0Nov 30, 2010Final
Citation 1, item 17d
29 CFR 1926.454(a) · Scaffold training
Serious$0$0Nov 30, 2010Final
Citation 1, item 18a
29 CFR 1926.152(a)(1) · Flammable liquids
Serious$1,050$0Nov 30, 2010Final
Citation 1, item 18b
29 CFR 1926.300(b)(2) · Tools—Hand and Power: general requirements
Serious$0$0Nov 30, 2010Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.152 · Flammable liquids

29 CFR 1926.152(a)(1)

(a) General requirements. (1) Only approved containers and portable tanks shall be used for storage and handling of flammable liquids. Approved safety cans or Department of Transportation approved containers shall be used for the handling and use of flammable liquids in quantities of 5 gallons or less, except that this shall not apply to those flammable liquid materials which are highly viscid (extremely hard to pour), which may be used and handled in original shipping containers. For quantities of one gallon or less, the original container may be used, for storage, use and handling of flammable liquids.

29 CFR 1926.20 · Construction safety programs

29 CFR 1926.20(b)(2)

(2) Such programs shall provide for frequent and regular inspections of the job sites, materials, and equipment to be made by competent persons designated by the employers.

29 CFR 1926.300 · Tools—Hand and Power: general requirements

29 CFR 1926.300(b)(2)

(2) Belts, gears, shafts, pulleys, sprockets, spindles, drums, fly wheels, chains, or other reciprocating, rotating or moving parts of equipment shall be guarded if such parts are exposed to contact by employees or otherwise create a hazard. Guarding shall meet the requirements as set forth in American National Standards Institute, B15.1-1953 (R1958), Safety Code for Mechanical Power-Transmission Apparatus.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.454 · Scaffold training

Other new single-family housing construction (except for-sale builders) employers in Virginia

Alert subscribers get notified of each newly cited employer in Virginia the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.