OSHA SearchOSHA records by employer

MTZ Screw Machine Products Inc: OSHA inspections and violations

El Paso, Texas · Machine Shops · NAICS 332710

1inspections
5citation items
$6,000current penalties
Feb 25, 2026last inspection

MTZ Screw Machine Products Inc has one OSHA inspection on record in Texas.

OSHA opened it on Feb 25, 2026 as a planned inspection, in El Paso, and the case has not closed yet.

From that inspection OSHA issued 5 citation items: 4 serious and 1 other-than-serious.

OSHA proposed $9,164 in penalties. After settlements and reviews the total is $6,000, down 35%.

Most often, OSHA cited 1910.303, electrical equipment, general requirements (2 items).

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $3,600. MTZ Screw Machine Products Inc averages $6,000 over 1 cited inspection in that time.

MTZ Screw Machine Products Inc: OSHA citation items per year, 2026 to 2026
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

399employers cited

5 of them in the same industry

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch MTZ Screw Machine Products Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348768599 OPENED FEB 25, 2026Open

Planned · Partial · Safety · 3 employees at the site · Open

13367 Round Dance Rd, El Paso, TX 79938 · Machine Shops · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.147(c)(1) · Lockout/tagout
Serious$2,412$1,500Aug 20, 2026Final
Citation 1, item 2
29 CFR 1910.157(e)(2) · Portable fire extinguishers
Serious$1,447$1,000Aug 20, 2026Final
Citation 1, item 3
29 CFR 1910.303(b)(7)(i) · Electrical equipment, general requirements
Serious$1,929$1,500Aug 20, 2026Final
Citation 1, item 4
29 CFR 1910.303(g)(2)(i) · Electrical equipment, general requirements
Serious$3,376$2,000Aug 20, 2026Final
Citation 2, item 1
29 CFR 1910.147(d)(4)(i) · Lockout/tagout
Other-than-serious$0$0Aug 20, 2026Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.147(c)(1)

(c) General—(1) Energy control program. The employer shall establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, start up or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source, and rendered inoperative.

29 CFR 1910.147(d)(4)(i)

(4) Lockout or tagout device application. (i) Lockout or tagout devices shall be affixed to each energy isolating device by authorized employees.

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.157(e)(2)

(2) Portable extinguishers or hose used in lieu thereof under paragraph (d)(3) of this section shall be visually inspected monthly.

29 CFR 1910.303 · Electrical equipment, general requirements

Other machine shops employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.