OSHA SearchOSHA records by employer

Multi Building, Inc.: OSHA inspections and violations

Fort Worth, Texas · Framing Contractors · NAICS 238130

19inspections
25citation items
$37,925current penalties
Jun 2, 2023last inspection

Multi Building, Inc. has 19 OSHA inspections on record in Texas, the first in 1997.

OSHA's last visit started on Jun 2, 2023 as part of a related case, in Houston.

Across those inspections OSHA issued 25 citation items: 18 serious, 2 repeat and 5 other-than-serious.

OSHA proposed $86,625 in penalties. After settlements and reviews the total is $37,925, down 56%.

Most often, OSHA cited 1926.451, scaffolds, general requirements (12 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Multi Building, Inc. averages $5,625 over 1 cited inspection in that time.

Multi Building, Inc.: OSHA citation items per year, 1997 to 2023
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

391employers cited

56 of them in the same industry

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch Multi Building, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 346746290 OPENED JUN 2, 2023Closed

Unprogrammed related · Partial · Safety · 30 employees at the site · Closed Aug 17, 2023

816 Addicks Hicks Rd, Houston, TX 77079 · Framing Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 346706179 OPENED APR 24, 2023Closed

Unprogrammed other · Partial · Safety · 1 employee at the site · Closed Jul 11, 2023

3880 Fm 2920 Bldg. 12, Spring, TX 77388 · New Multifamily Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 346526809 OPENED FEB 23, 2023Closed

Unprogrammed other · Partial · Safety · 17 employees at the site · Closed May 4, 2023

102 Richland Blvd., Prosper, TX 75078 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.20(b)(2) · Construction safety programs
Other-than-serious$5,625$5,625Apr 6, 2023Final

Inspection 339662041 OPENED APR 3, 2014Closed

Referral · Partial · Safety · 10 employees at the site · Closed Aug 21, 2014

777 Lake Caroline Parkway, Irving, TX 75039 · Framing Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 309543536 OPENED APR 11, 2007Closed

Planned · Complete · Safety · 75 employees at the site · Closed Oct 17, 2007

301 W. Los Colinas Blvd, Irving, TX 75039 · Flooring Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 308647098 OPENED JUN 30, 2005Closed

Unprogrammed related · Complete · Safety · 4 employees at the site · Closed Jun 30, 2006

500 W. Loop 820 South, Fort Worth, TX 76108 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Other-than-serious$4,000$1,800Aug 19, 2005Final

Inspection 308646710 OPENED JUN 13, 2005Closed

Unprogrammed related · Partial · Safety · 1 employee at the site · Closed Jun 16, 2005

7001 Sandshell Blvd., Fort Worth, TX 76137 · Framing Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 306570839 OPENED SEP 23, 2004Closed

Unprogrammed related · Partial · Safety · 3 employees at the site · Closed Sep 30, 2005

15200 Memorial Drive Bldg 16 Unit 1601, Houston, TX 77079 · Framing Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

11 older inspections

Inspection 306481334 OPENED JUL 2, 2004Closed

Unprogrammed related · Partial · Safety · 75 employees at the site · Closed Jul 6, 2004

14515 Briar Forest Dr, Houston, TX 77077 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 307484543 OPENED APR 30, 2004Closed

Unprogrammed related · Partial · Safety · 2 employees at the site · Closed Aug 2, 2004

1050 Lake Carolyn Parkway, Irving, TX 75039 · Framing Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 305465783 OPENED APR 30, 2003Closed

Planned · Partial · Safety · 4 employees at the site · Closed Sep 4, 2003

500 W. Bruton, 054666spring, TX 75180 · Framing Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 122179286 OPENED AUG 30, 2002Closed

Unprogrammed other · Partial · Safety · 3 employees at the site · Closed Oct 16, 2003

221 Stoneport, Dallas, TX 75217 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 2
29 CFR 1926.501(b)(13) · Fall protection in construction
Other-than-serious$2,800$2,800Dec 13, 2002Final

Inspection 110038627 OPENED OCT 24, 2001Closed

Unprogrammed related · Partial · Safety · 4 employees at the site · Closed Sep 25, 2002

650 E. Vista Ridge Mall Dr., Lewisville, TX 75067 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(a)(6) · Scaffolds, general requirements
Serious$1,000$600Dec 14, 2001Final
Citation 1, item 2
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Serious$1,000$600Dec 14, 2001Final
Citation 1, item 3
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Serious$1,000$600Dec 14, 2001Final
Citation 1, item 4
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$1,000$600Dec 14, 2001Final
Citation 1, item 5
29 CFR 1926.452(j)(2) · Rules for each type of scaffold
Serious$1,000$600Dec 14, 2001Final

Inspection 304267321 OPENED JUL 25, 2001Closed

Unprogrammed other · Partial · Safety · 3 employees at the site · Closed Feb 14, 2003

4699 Fossil Vista, Fort Worth, TX 76137 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$2,500$1,500Sep 14, 2001Final
Citation 2, item 1
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Repeat$4,000$1,500Sep 14, 2001Final

Inspection 302575824 OPENED DEC 18, 2000Closed

Planned · Complete · Safety · 300 employees at the site · Closed Mar 5, 2002

4630 Magnolia Cove Dr., Kingwood, TX 77345 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.1052(c)(1) · Stairways in construction
Serious$2,500$2,500Mar 2, 2001Final
Citation 2, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Repeat$25,000$5,000Mar 2, 2001Final

Inspection 302657432 OPENED OCT 27, 1999Closed

Unprogrammed other · Partial · Safety · 4 employees at the site · Closed Sep 19, 2000

9385 Boat Club Road, Fort Worth, TX 76179 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 4a
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$0$2,000Feb 18, 2000Final
Citation 1, item 4b
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Serious$0$0Feb 18, 2000Final
Citation 1, item 4c
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$0$0Feb 18, 2000Final
Citation 1, item 4d
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$0$0Feb 18, 2000Final

Inspection 302654421 OPENED APR 21, 1999Closed

Planned · Partial · Safety · 3 employees at the site · Closed Sep 13, 2000

4699 Fossil Vista, Fort Worth, TX 76137 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(2) · Scaffolds, general requirements
Serious$2,000$1,500Jun 7, 1999Final
Citation 1, item 2
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$2,000$1,500Jun 7, 1999Final
Citation 1, item 3
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Serious$2,000$1,000Jun 7, 1999Final
Citation 2, item 1
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$28,000$7,000Jun 7, 1999Final

Inspection 300519899 OPENED NOV 2, 1998Closed

Unprogrammed related · Partial · Safety · 20 employees at the site · Closed Nov 18, 1998

4699 Fossil Vista, Fort Worth, TX 76137 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.100(a) · Hard hats in construction
Serious$600$600Nov 12, 1998Closed
Citation 1, item 2a
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$600$600Nov 12, 1998Closed
Citation 1, item 2b
29 CFR 1926.501(b)(14) · Fall protection in construction
Serious$0$0Nov 12, 1998Closed

Inspection 300515319 OPENED NOV 4, 1997Closed

Planned · Partial · Safety · 20 employees at the site · Closed Mar 13, 1998

901 Lakeside Circle, Lewisville, TX 75057 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.307(d)(1) · Mechanical power-transmission apparatus
Other-than-serious$0$0Jan 23, 1998Closed
Citation 1, item 1b
29 CFR 1926.307(e)(1)(i) · Mechanical power-transmission apparatus
Other-than-serious$0$0Jan 23, 1998Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.100 · Hard hats in construction

29 CFR 1926.100(a)

(a) Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, shall be protected by protective helmets.

29 CFR 1926.1052 · Stairways in construction

29 CFR 1926.1052(c)(1)

(1) Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, shall be equipped with:

29 CFR 1926.20 · Construction safety programs

29 CFR 1926.20(b)(2)

(2) Such programs shall provide for frequent and regular inspections of the job sites, materials, and equipment to be made by competent persons designated by the employers.

29 CFR 1926.307 · Mechanical power-transmission apparatus

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.501 · Fall protection in construction

Other framing contractors employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.