OSHA SearchOSHA records by employer

Munson and Bryan Electric Company, Inc.: OSHA inspections and violations

Jacksonville, Florida · Electrical Contractors and Other Wiring Installation Contractors · NAICS 238210

5inspections
8citation items
$42,818current penalties
Jan 17, 2024last inspection

Since 1999, OSHA inspectors have visited Munson and Bryan Electric Company, Inc. in Florida 5 times.

The most recent inspection opened on Jan 17, 2024 on a referral, in Jacksonville.

In all, OSHA issued 8 citation items: 7 serious and 1 other-than-serious.

The proposed penalties came to $150,822; today they stand at $42,818, 72% less.

The rule cited most here is 1926.416 (electrical safety in construction), 2 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Munson and Bryan Electric Company, Inc. averages $19,409 across 2 cited inspections.

It reported 2 severe injuries to OSHA since 2015.

Munson and Bryan Electric Company, Inc.: OSHA citation items per year, 1999 to 2024
Citation items per year, by inspection date.

Florida · latest 90 days of OSHA records

316employers cited

4 of them in the same industry

Get notified the morning OSHA posts each new citation in Florida: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Florida

Checking a subcontractor, a client or your own company? Watch Munson and Bryan Electric Company, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347213894 OPENED JAN 17, 2024Closed

Referral · Partial · Safety · 4 employees at the site · Closed Jan 7, 2025

5800 Beach Blvd., Jacksonville, FL 32207 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.416(a)(1) · Electrical safety in construction
Serious$129,058$25,000Jul 3, 2024Final
Citation 2, item 1
29 CFR 1904.39(a)(2) · Reporting deaths and severe injuries
Other-than-serious$8,067$8,000Jul 3, 2024Final

Inspection 342728490 OPENED OCT 25, 2017Closed

Referral · Complete · Safety · 3 employees at the site · Closed Jan 12, 2018

40 Everest Lane, Jacksonville, FL 32216 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.100(a) · Hard hats in construction
Serious$4,310$2,586Nov 17, 2017Final
Citation 1, item 2
29 CFR 1926.453(b)(2)(v) · Aerial lifts
Serious$5,387$3,232Nov 17, 2017Final

Inspection 313873325 OPENED DEC 2, 2009Closed

Planned · Complete · Safety · 4 employees at the site · Closed Feb 2, 2010

87 Nocatee Village Drive, St Augustine, FL 32081 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.178(l)(1)(i) · Forklifts and other powered industrial trucks
Serious$1,125$1,125Jan 8, 2010Closed
Citation 1, item 2
29 CFR 1926.100(a) · Hard hats in construction
Serious$1,125$1,125Jan 8, 2010Closed

Inspection 313872889 OPENED NOV 9, 2009Closed

Planned · Complete · Safety · 2 employees at the site · Closed Dec 23, 2009

101 San Marco Blvd, St Augustine, FL 32082 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.416(a)(1) · Electrical safety in construction
Serious$875$875Dec 15, 2009Closed
Citation 1, item 2
29 CFR 1926.417(b) · Lockout and tagging of circuits
Serious$875$875Dec 15, 2009Closed

Inspection 302732490 OPENED AUG 2, 1999Closed

Unprogrammed related · Complete · Safety · 3 employees at the site · Closed Aug 13, 1999

9790 Touchton Road, Jacksonville, FL 32216 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 2 reports on file.

Jan 9, 2024, Jacksonville: Hospitalization · electrical burns any degree · multiple body parts n.e.c.

On January 9, 2024, an employee was pulling wire out of a meter can when the wire touched the meter, causing an arc flash. The employee was hospitalized with burns to their face, neck, and shoulder.

Jun 5, 2019, Jacksonville: Hospitalization · fractures · multiple trunk locations

On June 5, 2019, an electrician was performing electrical work at an assisted living facility that was under construction. He was working with a junction box at an open ceiling grid from an 8-foot A-frame ladder when he was shocked and fell to the ground. He suffered several broken ribs, a head contusion and fractures to the L3 an L4 vertebrae. He was hospitalized.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1904.39 · Reporting deaths and severe injuries

29 CFR 1904.39(a)(2)

(2) Within twenty-four (24) hours after the in-patient hospitalization of one or more employees or an employee's amputation or an employee's loss of an eye, as a result of a work-related incident, you must report the in-patient hospitalization, amputation, or loss of an eye to OSHA.

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.178(l)(1)(i)

(l) Operator training. (1) Safe operation. (i) The employer shall ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l).

29 CFR 1926.100 · Hard hats in construction

29 CFR 1926.100(a)

(a) Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, shall be protected by protective helmets.

29 CFR 1926.416 · Electrical safety in construction

29 CFR 1926.417 · Lockout and tagging of circuits

29 CFR 1926.453 · Aerial lifts

Other electrical contractors and other wiring installation contractors employers in Florida

Alert subscribers get notified of each newly cited employer in Florida the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.