Inspection 344662986 OPENED FEB 27, 2020Closed
109 W. College Street, Winnsboro, SC 29180 · Roofing Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Columbia, South Carolina · Roofing Contractors · NAICS 238160
Since 1984, OSHA inspectors have visited Murr - Laney Inc in South Carolina 4 times.
The most recent inspection opened on Feb 27, 2020 as a planned inspection, in Winnsboro.
In all, OSHA issued 5 citation items: 4 serious and 1 other-than-serious.
The penalties, $525 in total, stand where OSHA first set them.
The rule cited most here is 1926.451 (scaffolds, general requirements), 4 times.
Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Murr - Laney Inc averages $125 across 1 cited inspection.
South Carolina · latest 90 days of OSHA records
43employers cited
Get notified the morning OSHA posts each new citation in South Carolina: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in South Carolina
Checking a subcontractor, a client or your own company? Watch Murr - Laney Inc and get notified the morning OSHA posts a new citation for it.
Watch this company109 W. College Street, Winnsboro, SC 29180 · Roofing Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
2 S Congress Street, York, SC 29745 · Roofing Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.451(e)(4)(i) · Scaffolds, general requirements |
Serious | $125 | $125 | May 4, 2016 | Final |
325 W. Mcbee Ave., Greenville, SC 29602 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
401 South Main Street, Columbia, SC 29211 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 2, item 1a 29 CFR 1926.451(d)(10) · Scaffolds, general requirements |
Serious | $400 | $400 | Mar 15, 1984 | Closed |
| Citation 2, item 1b 29 CFR 1926.451(d)(7) · Scaffolds, general requirements |
Serious | $0 | $0 | Mar 15, 1984 | Closed |
| Citation 2, item 1c 29 CFR 1926.451(d)(3) · Scaffolds, general requirements |
Serious | $0 | $0 | Mar 15, 1984 | Closed |
| Citation 3, item 1 29 CFR 1926.400(h)(1) · Introduction |
Other-than-serious | $0 | $0 | Mar 15, 1984 | Closed |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1926.451(d)(10)
(10) Ropes shall be inspected for defects by a competent person prior to each workshift and after every occurrence which could affect a rope's integrity. Ropes shall be replaced if any of the following conditions exist:
29 CFR 1926.451(d)(3)
(3) The inboard ends of suspension scaffold outrigger beams shall be stabilized by bolts or other direct connections to the floor or roof deck, or they shall have their inboard ends stabilized by counterweights, except masons' multi-point adjustable suspension scaffold outrigger beams shall not be stabilized by counterweights.
29 CFR 1926.451(d)(7)
(7) The use of repaired wire rope as suspension rope is prohibited.
Alert subscribers get notified of each newly cited employer in South Carolina the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.