OSHA SearchOSHA records by employer

Naples Drywall & Plastering, Inc.: OSHA inspections and violations

Naples, Florida · All Other Specialty Trade Contractors · NAICS 238990

1inspections
5citation items
$6,653current penalties
Apr 25, 2018last inspection

Naples Drywall & Plastering, Inc. has one OSHA inspection on record in Florida.

OSHA opened it on Apr 25, 2018 on a referral, in Naples.

From that inspection OSHA issued 5 citation items: 5 serious.

OSHA proposed $11,088 in penalties. After settlements and reviews the total is $6,653, down 40%.

Most often, OSHA cited 1926.451, scaffolds, general requirements (5 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Naples Drywall & Plastering, Inc. averages $6,653 over 1 cited inspection in that time.

Naples Drywall & Plastering, Inc.: OSHA citation items per year, 2018 to 2018
Citation items per year, by inspection date.

Florida · latest 90 days of OSHA records

319employers cited

3 of them in the same industry

Get notified the morning OSHA posts each new citation in Florida: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Florida

Checking a subcontractor, a client or your own company? Watch Naples Drywall & Plastering, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343113429 OPENED APR 25, 2018Closed

Referral · Partial · Safety · 5 employees at the site · Closed Oct 15, 2019

185 Pago Pago Drive West, Naples, FL 34113 · All Other Specialty Trade Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$2,772$1,663Aug 6, 2018Final
Citation 1, item 2
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Serious$2,772$1,663Aug 6, 2018Final
Citation 1, item 3
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$2,772$1,663Aug 6, 2018Final
Citation 1, item 4a
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$2,772$1,663Aug 6, 2018Final
Citation 1, item 4b
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Serious$0$0Aug 6, 2018Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)

(b) Scaffold platform construction. (1) Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows:

29 CFR 1926.451(c)(2)

(2) Supported scaffold poles, legs, posts, frames, and uprights shall bear on base plates and mud sills or other adequate firm foundation.

29 CFR 1926.451(e)(1)

(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.

Other all other specialty trade contractors employers in Florida

Alert subscribers get notified of each newly cited employer in Florida the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.