OSHA SearchOSHA records by employer

Narvick Bros. Lumber Co. Inc.: OSHA inspections and violations

Morris, Illinois · Other Building Material Dealers · NAICS 444190

3inspections
43citation items
$80,420current penalties
Apr 3, 2024last inspection

Since 1975, OSHA inspectors have visited Narvick Bros. Lumber Co. Inc. in Illinois 3 times.

The most recent inspection opened on Apr 3, 2024 after a fatality or catastrophe, in Morris.

In all, OSHA issued 43 citation items: 16 serious and 27 other-than-serious.

The proposed penalties came to $106,890; today they stand at $80,420, 25% less.

The rule cited most here is 1910.146 (permit-required confined spaces), 9 times.

Among retail employers, the typical cited inspection since 2015 ends with a $1,750 penalty. Narvick Bros. Lumber Co. Inc. averages $80,000 across 1 cited inspection.

1 inspection on this page followed a fatal incident.

Narvick Bros. Lumber Co. Inc.: OSHA citation items per year, 1975 to 2024
Citation items per year, by inspection date.

Illinois · latest 90 days of OSHA records

421employers cited

Get notified the morning OSHA posts each new citation in Illinois: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Illinois

Checking a subcontractor, a client or your own company? Watch Narvick Bros. Lumber Co. Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347390932 OPENED APR 3, 2024Closed

Fatality or catastrophe · Partial · Safety · 2 employees at the site · Closed Nov 22, 2024

785 East Route 6, Morris, IL 60450 · Other Building Material Dealers · OSHA's record · Phone and website on Google Maps

Incident on Apr 3, 2024 (fatal): Employee dies of trauma when knocked to bottom of mixer

At 9:00 a.m. on April 3, 2024, an employee working as a plant operator for building materials manufacturer was reinstalling mixer blades onto the shaft inside a Vince Hagan HM-10 Horizontal Concrete Mixer. The employee had been on a crew between January 2024 and April 2024 engaged in the shaft and blade replacement and repair project involving the portable concrete mixer. The mixer sits approximately 6-foot high on a steel trailer frame. The entire assembly is designed to be raised and inserted as a component into a batch plant. The shaft sits within the mixer drum, which is approximately 15-foot long and 8-foot wide. The internal configuration includes a shaft down the center equipped with 4 blades. The employee was working with a coworker reinstalling the fourth and final blade onto the shaft. Two of the blades were at an approximate 9 o'clock position. The third blade was at an approximate 4 o'clock position. Both the employee and the coworker were inside the mixer drum attempting to rotate the blades to position to facilitate the installation of the final blade. They had attempted to spin the assembly using their own body weight. The first and second blades were jammed. Residual aggregate concrete had lodged between the blade and the outer wall of the drum. They placed a handheld chain hoist onto the lip of the drum and wrapped it around the second blade. The employee applied tension to the hoist chain and the first and second blades broke free and spun approximately 180 degrees. This created an unbalanced top-heavy condition when placed under tension with the hoist. Upon breaking free, the two blades spun and came to rest at the bottom leaving the blades in a reversed position. The coworker was able to maintain his balance, but the employee was struck in the chest by a portion of the blade and was knocked to the bottom of the drum. The employee died from blunt force chest trauma.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.67(c)(2)(ii) · Vehicle-mounted elevating and rotating work platforms
Serious$8,067$4,135Sep 13, 2024Final
Citation 1, item 2
29 CFR 1910.67(c)(2)(v) · Vehicle-mounted elevating and rotating work platforms
Serious$8,067$4,135Sep 13, 2024Final
Citation 1, item 3
29 CFR 1910.146(c)(1) · Permit-required confined spaces
Serious$11,292$10,073Sep 13, 2024Final
Citation 1, item 4
29 CFR 1910.146(c)(2) · Permit-required confined spaces
Serious$11,292$5,646Sep 13, 2024Final
Citation 1, item 5a
29 CFR 1910.146(d)(3)(iii) · Permit-required confined spaces
Serious$11,292$10,073Sep 13, 2024Final
Citation 1, item 5b
29 CFR 1910.147(c)(4)(i) · Lockout/tagout
Serious$0$0Sep 13, 2024Final
Citation 1, item 5c
29 CFR 1910.147(d)(5)(i) · Lockout/tagout
Serious$0$0Sep 13, 2024Final
Citation 1, item 5d
29 CFR 1910.147(d)(6) · Lockout/tagout
Serious$0$0Sep 13, 2024Final
Citation 1, item 6a
29 CFR 1910.146(d)(4)(vii) · Permit-required confined spaces
Serious$11,292$5,646Sep 13, 2024Final
Citation 1, item 6b
29 CFR 1910.146(d)(4)(ix) · Permit-required confined spaces
Serious$0$0Sep 13, 2024Final
Citation 1, item 6c
29 CFR 1910.28(b)(6)(i) · Fall protection in general industry
Serious$0$0Sep 13, 2024Final
Citation 1, item 7
29 CFR 1910.146(d)(6) · Permit-required confined spaces
Serious$11,292$10,073Sep 13, 2024Final
Citation 1, item 8
29 CFR 1910.146(d)(9) · Permit-required confined spaces
Serious$11,292$10,073Sep 13, 2024Final
Citation 1, item 9
29 CFR 1910.146(e)(1) · Permit-required confined spaces
Serious$11,292$10,073Sep 13, 2024Final
Citation 1, item 10a
29 CFR 1910.146(g)(1) · Permit-required confined spaces
Serious$11,292$10,073Sep 13, 2024Final
Citation 1, item 10b
29 CFR 1910.147(c)(7)(i)(a) · Lockout/tagout
Serious$0$0Sep 13, 2024Final

Inspection 214704900 OPENED SEP 2, 1975Closed

Planned · Complete · Safety · 15 employees at the site · Closed Jan 27, 1976

North Broadway, Coal City, IL 60416 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.152(a) · Flammable liquids
Other-than-serious$25$25Sep 29, 1975Closed

Inspection 214771727 OPENED APR 24, 1975Closed

Planned · Partial · Safety · 25 employees at the site · Closed Sep 8, 1975

1037 Armstrong, Morris, IL 60450 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.106(g)(8) · Flammable liquids
Other-than-serious$0$0May 23, 1975Closed
Citation 1, item 2 Other-than-serious$25$25May 23, 1975Closed
Citation 1, item 3 Other-than-serious$0$0May 23, 1975Closed
Citation 1, item 4
29 CFR 1910.110(f)(2)(iiib)(0) · Storage and handling of liquefied petroleum gases
Other-than-serious$0$0May 23, 1975Closed
Citation 1, item 5
29 CFR 1910.22(d)(1) · General requirements
Other-than-serious$0$0May 23, 1975Closed
Citation 1, item 6
29 CFR 1910.157(b)(2)(i) · Portable fire extinguishers
Other-than-serious$25$25May 23, 1975Closed
Citation 1, item 7
29 CFR 1910.157(c)(1)(ii) · Portable fire extinguishers
Other-than-serious$55$55May 23, 1975Closed
Citation 1, item 8
29 CFR 1910.37(q)(1) · Exit routes
Other-than-serious$0$0May 23, 1975Closed
Citation 1, item 9
29 CFR 1910.101(b) · Compressed gases (general requirements)
Other-than-serious$25$25May 23, 1975Closed
Citation 1, item 10
29 CFR 1910.252(a)(2)(ivc)(0) · Welding fire safety
Other-than-serious$0$0May 23, 1975Closed
Citation 1, item 11 Other-than-serious$25$25May 23, 1975Closed
Citation 1, item 12
29 CFR 1910.23(c)(1) · Guarding floor and wall openings and holes
Other-than-serious$0$0May 23, 1975Closed
Citation 1, item 13
29 CFR 1910.37(f)(5) · Exit routes
Other-than-serious$25$25May 23, 1975Closed
Citation 1, item 14
29 CFR 1910.215(a)(2) · Grinders and abrasive wheels
Other-than-serious$25$25May 23, 1975Closed
Citation 1, item 15 Other-than-serious$25$25May 23, 1975Closed
Citation 1, item 16a
29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts
Other-than-serious$40$40May 23, 1975Closed
Citation 1, item 16b
29 CFR 1910.219(e)(1)(i) · Belts, pulleys and power-transmission parts
Other-than-serious$0$0May 23, 1975Closed
Citation 1, item 17
29 CFR 1910.23(d)(1) · Guarding floor and wall openings and holes
Other-than-serious$25$25May 23, 1975Closed
Citation 1, item 18a
29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts
Other-than-serious$25$25May 23, 1975Closed
Citation 1, item 18b
29 CFR 1910.219(e)(3)(i) · Belts, pulleys and power-transmission parts
Other-than-serious$0$0May 23, 1975Closed
Citation 1, item 19
29 CFR 1910.213(h)(1) · Woodworking machinery
Other-than-serious$25$25May 23, 1975Closed
Citation 1, item 20
29 CFR 1910.213(h)(4) · Woodworking machinery
Other-than-serious$0$0May 23, 1975Closed
Citation 1, item 21
29 CFR 1910.213(d)(1) · Woodworking machinery
Other-than-serious$25$25May 23, 1975Closed
Citation 1, item 22
29 CFR 1910.22(a)(1) · General requirements
Other-than-serious$25$25May 23, 1975Closed
Citation 1, item 23
29 CFR 1910.133(a)(1) · Eye and face protection
Other-than-serious$0$0May 23, 1975Closed
Citation 1, item 24
29 CFR 1910.106(b)(5)(iv) · Flammable liquids
Other-than-serious$0$0May 23, 1975Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.101 · Compressed gases (general requirements)

29 CFR 1910.101(b)

(b) Compressed gases. The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks shall be in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in § 1910.6.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(g)(8)

(8) Sources of ignition. In addition to the previous restrictions of this paragraph, the following shall apply: There shall be no smoking or open flames in the areas used for fueling, servicing fuel systems for internal combustion engines, receiving or dispensing of flammable liquids. Conspicuous and legible signs prohibiting smoking shall be posted within sight of the customer being served. The motors of all equipment being fueled shall be shut off during the fueling operation.

29 CFR 1910.110 · Storage and handling of liquefied petroleum gases

29 CFR 1910.110(f)(2)(iiib)(0)

(iii) Container valves shall be protected while in storage as follows:

29 CFR 1910.133 · Eye and face protection

29 CFR 1910.146 · Permit-required confined spaces

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.213 · Woodworking machinery

29 CFR 1910.215 · Grinders and abrasive wheels

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.22 · General requirements

29 CFR 1910.23 · Guarding floor and wall openings and holes

29 CFR 1910.252 · Welding fire safety

29 CFR 1910.28 · Fall protection in general industry

29 CFR 1910.309

29 CFR 1910.37 · Exit routes

29 CFR 1910.67 · Vehicle-mounted elevating and rotating work platforms

29 CFR 1926.152 · Flammable liquids

Other other building material dealers employers in Illinois

Alert subscribers get notified of each newly cited employer in Illinois the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.