OSHA SearchOSHA records by employer

Nashville Auto Sales, LLC: OSHA inspections and violations

Nashville, Tennessee · Used Car Dealers · NAICS 441120

1inspections
16citation items
$1,400current penalties
Jun 18, 2015last inspection

OSHA inspectors have visited Nashville Auto Sales, LLC in Tennessee one time.

It opened on Jun 18, 2015 on a referral, in Nashville.

In all, OSHA issued 16 citation items: 10 serious and 6 other-than-serious.

The penalties, $1,400 in total, stand where OSHA first set them.

The rule cited most here is 1910.107 (spray painting and finishing), 5 times.

Among retail employers, the typical cited inspection since 2015 ends with a $1,750 penalty. Nashville Auto Sales, LLC averages $1,400 across 1 cited inspection.

Nashville Auto Sales, LLC: OSHA citation items per year, 2015 to 2015
Citation items per year, by inspection date.

Tennessee · latest 90 days of OSHA records

318employers cited

Get notified the morning OSHA posts each new citation in Tennessee: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Tennessee

Checking a subcontractor, a client or your own company? Watch Nashville Auto Sales, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340713585 OPENED JUN 18, 2015Closed

Referral · Partial · Health · 8 employees at the site · Closed Nov 17, 2015

504 Interstate Blvd S, Nashville, TN 37210 · Used Car Dealers · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.107(b)(5)(i) · Spray painting and finishing
Serious$500$500Aug 4, 2015Final
Citation 1, item 1b
29 CFR 1910.107(b)(5)(iv) · Spray painting and finishing
Serious$0$0Aug 4, 2015Final
Citation 1, item 1c
29 CFR 1910.107(b)(9) · Spray painting and finishing
Serious$0$0Aug 4, 2015Final
Citation 1, item 1d
29 CFR 1910.107(b)(10) · Spray painting and finishing
Serious$0$0Aug 4, 2015Final
Citation 1, item 1e
29 CFR 1910.107(e)(2) · Spray painting and finishing
Serious$0$0Aug 4, 2015Final
Citation 1, item 2
29 CFR 1910.133(a)(1) · Eye and face protection
Serious$400$400Aug 4, 2015Final
Citation 1, item 3a
29 CFR 1910.134(c)(2)(i) · Respiratory protection
Serious$500$500Aug 4, 2015Final
Citation 1, item 3b
29 CFR 1910.134(c)(2)(ii) · Respiratory protection
Serious$0$0Aug 4, 2015Final
Citation 1, item 3c
29 CFR 1910.134(h)(1) · Respiratory protection
Serious$0$0Aug 4, 2015Final
Citation 1, item 3d
29 CFR 1910.134(h)(2)(i) · Respiratory protection
Serious$0$0Aug 4, 2015Final
Citation 2, item 1a
29 CFR 1910.157(c)(1) · Portable fire extinguishers
Other-than-serious$0$0Aug 4, 2015Final
Citation 2, item 1b
29 CFR 1910.157(e)(2) · Portable fire extinguishers
Other-than-serious$0$0Aug 4, 2015Final
Citation 2, item 1c
29 CFR 1910.157(e)(3) · Portable fire extinguishers
Other-than-serious$0$0Aug 4, 2015Final
Citation 2, item 2a
29 CFR 1910.1200(h)(1) · Hazard communication
Other-than-serious$0$0Aug 4, 2015Final
Citation 2, item 2b
29 CFR 1910.1200(e)(1) · Hazard communication
Other-than-serious$0$0Aug 4, 2015Final
Citation 2, item 2c
29 CFR RULE 800-01-09-.07(4)
Other-than-serious$0$0Aug 4, 2015Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.107(b)(10)

(10) Illumination. When spraying areas are illuminated through glass panels or other transparent materials, only fixed lighting units shall be used as a source of illumination. Panels shall effectively isolate the spraying area from the area in which the lighting unit is located, and shall be of a noncombustible material of such a nature or so protected that breakage will be unlikely. Panels shall be so arranged that normal accumulations of residue on the exposed surface of the panel will not be raised to a dangerous temperature by radiation or conduction from the source of illumination.

29 CFR 1910.107(b)(5)(i)

(i) The spraying operations except electrostatic spraying operations shall be so designed, installed and maintained that the average air velocity over the open face of the booth (or booth cross section during spraying operations) shall be not less than 100 linear feet per minute. Electrostatic spraying operations may be conducted with an air velocity over the open face of the booth of not less than 60 linear feet per minute, or more, depending on the volume of the finishing material being applied and its flammability and explosion characteristics. Visible gauges or audible alarm or pressure activated devices shall be installed to indicate or insure that the required air velocity is maintained. Filter rolls shall be inspected to insure proper replacement of filter media.

29 CFR 1910.107(b)(5)(iv)

(iv) Space within the spray booth on the downstream and upstream sides of filters shall be protected with approved automatic sprinklers.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.133 · Eye and face protection

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.157 · Portable fire extinguishers

Other used car dealers employers in Tennessee

Alert subscribers get notified of each newly cited employer in Tennessee the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.