OSHA SearchOSHA records by employer

National Plastics Color, Inc: OSHA inspections and violations

Valley Center, Kansas · All Other Plastics Product Manufacturing · NAICS 326199

10inspections
34citation items
$12,096current penalties
Jan 26, 2021last inspection

National Plastics Color, Inc has 10 OSHA inspections on record in Kansas, the first in 1992.

OSHA's last visit started on Jan 26, 2021 after a complaint, in Valley Center.

Across those inspections OSHA issued 34 citation items: 9 serious and 25 other-than-serious.

OSHA proposed $18,602 in penalties. After settlements and reviews the total is $12,096, down 35%.

Most often, OSHA cited 1910.134, respiratory protection (5 items).

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $4,500. National Plastics Color, Inc averages $1,901 over 1 cited inspection in that time.

National Plastics Color, Inc also files yearly injury logs with OSHA, summarized below.

National Plastics Color, Inc: OSHA citation items per year, 1992 to 2021
Citation items per year, by inspection date.

Kansas · latest 90 days of OSHA records

49employers cited

Get notified the morning OSHA posts each new citation in Kansas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Kansas

Checking a subcontractor, a client or your own company? Watch National Plastics Color, Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345119994 OPENED JAN 26, 2021Closed

Complaint · Partial · Health · 103 employees at the site · Closed Apr 9, 2021

100 W Industrial, Valley Center, KS 67147 · Plastics Material and Resin Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 342524915 OPENED AUG 3, 2017Closed

Planned · Partial · Health · 99 employees at the site · Closed Oct 18, 2017

100 W Industrial, Valley Center, KS 67147 · Plastics Material and Resin Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.110(e)(4)(iii) · Storage and handling of liquefied petroleum gases
Other-than-serious$3,802$1,901Sep 13, 2017Final

Inspection 334107828 OPENED MAY 2, 2012Closed

Complaint · Partial · Safety · 80 employees at the site · Closed Jul 5, 2012

100 W Industrial, Valley Center, KS 67147 · All Other Plastics Product Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 334108024 OPENED MAY 2, 2012Closed

Planned · Partial · Health · 80 employees at the site · Closed Oct 26, 2012

100 W Industrial, Valley Center, KS 67147 · All Other Plastics Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.134(f)(2) · Respiratory protection
Other-than-serious$2,100$1,470Aug 31, 2012Final
Citation 2, item 1
29 CFR 1910.134(f)(5) · Respiratory protection
Other-than-serious$0$0Aug 31, 2012Final

Inspection 310780077 OPENED OCT 11, 2007Closed

Planned · Complete · Safety · 135 employees at the site · Closed Nov 7, 2007

100 W Industrial, Valley Center, KS 67147 · All Other Plastics Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.23(c)(1) · Guarding floor and wall openings and holes
Serious$1,400$700Oct 30, 2007Closed

Inspection 306172669 OPENED DEC 2, 2003Closed

Planned · Complete · Safety · 112 employees at the site · Closed Jan 14, 2004

2600 W 77th St N, Valley Center, KS 67147 · All Other Plastics Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.36(d)(1) · Exit route design
Serious$825$412Dec 24, 2003Closed
Citation 1, item 2
29 CFR 1910.36(g)(1) · Exit route design
Serious$825$412Dec 24, 2003Closed
Citation 1, item 3a
29 CFR 1910.36(g)(2) · Exit route design
Serious$825$412Dec 24, 2003Closed
Citation 1, item 3b
29 CFR 1910.37(a)(3) · Exit routes
Serious$0$0Dec 24, 2003Closed
Citation 1, item 4
29 CFR 1910.303(g)(1)(i) · Electrical equipment, general requirements
Serious$825$412Dec 24, 2003Closed
Citation 1, item 5a
29 CFR 1910.305(a)(2)(iiif) · Electrical wiring methods
Serious$825$412Dec 24, 2003Closed
Citation 1, item 5b
29 CFR 1910.305(j)(1)(i) · Electrical wiring methods
Serious$0$0Dec 24, 2003Closed
Citation 2, item 1
29 CFR 1910.23(a)(8) · Guarding floor and wall openings and holes
Other-than-serious$0$0Dec 24, 2003Closed
Citation 2, item 2
29 CFR 1910.23(e)(2) · Guarding floor and wall openings and holes
Other-than-serious$0$0Dec 24, 2003Closed
Citation 2, item 3
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Other-than-serious$0$0Dec 24, 2003Closed
Citation 2, item 4
29 CFR 1910.303(f) · Electrical equipment, general requirements
Other-than-serious$0$0Dec 24, 2003Closed
Citation 2, item 5
29 CFR 1910.304(f)(1)(iv) · Grounding and circuit protection
Other-than-serious$0$0Dec 24, 2003Closed
Citation 2, item 6
29 CFR 1910.304(f)(5)(v) · Grounding and circuit protection
Other-than-serious$0$0Dec 24, 2003Closed
Citation 2, item 7
29 CFR 1910.305(b)(1) · Electrical wiring methods
Other-than-serious$0$0Dec 24, 2003Closed
Citation 2, item 8
29 CFR 1910.305(b)(2) · Electrical wiring methods
Other-than-serious$0$0Dec 24, 2003Closed
Citation 2, item 9
29 CFR 1910.334(a)(2)(i) · Using electrical equipment
Other-than-serious$0$0Dec 24, 2003Closed

Inspection 306171877 OPENED OCT 29, 2003Closed

Planned · Complete · Health · 112 employees at the site · Closed Jan 26, 2004

2600 W 77th St N, Valley Center, KS 67147 · All Other Plastics Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.146(c)(2) · Permit-required confined spaces
Other-than-serious$0$0Jan 8, 2004Closed
Citation 1, item 2
29 CFR 1910.1200(f)(5)(i) · Hazard communication
Other-than-serious$0$0Jan 8, 2004Closed
Citation 1, item 3
29 CFR 1910.1200(f)(5)(ii) · Hazard communication
Other-than-serious$0$0Jan 8, 2004Closed

Inspection 301015814 OPENED JAN 12, 1999Closed

Planned · Complete · Safety · 125 employees at the site · Closed Mar 17, 1999

2600 W 77th St N, Valley Center, KS 67147 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.37(f)(6) · Exit routes
Other-than-serious$0$0Feb 22, 1999Closed
Citation 1, item 2
29 CFR 1910.304(a)(2) · Grounding and circuit protection
Other-than-serious$0$0Feb 22, 1999Closed
2 older inspections

Inspection 301008249 OPENED APR 2, 1997Closed

Planned · Complete · Health · 105 employees at the site · Closed Dec 22, 1997

2600 W 77th St N, Valley Center, KS 67147 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.24(b) · Fixed industrial stairs
Other-than-serious$1,750$875Sep 12, 1997Closed
Citation 1, item 2
29 CFR 1910.25(d)(2)(xii) · Portable wood ladders
Other-than-serious$825$0Sep 12, 1997Closed
Citation 1, item 3b Other-than-serious$0$688Sep 12, 1997Closed
Citation 1, item 4b
29 CFR 1910.134(e)(5)(i) · Respiratory protection
Other-than-serious$0$1,225Sep 12, 1997Closed
Citation 1, item 4c
29 CFR 1910.134(f)(1) · Respiratory protection
Other-than-serious$0$0Sep 12, 1997Closed
Citation 1, item 4d
29 CFR 1910.134(f)(3) · Respiratory protection
Other-than-serious$0$0Sep 12, 1997Closed
Citation 1, item 5
29 CFR 1910.146(c)(1) · Permit-required confined spaces
Other-than-serious$1,100$550Sep 12, 1997Closed
Citation 1, item 6
29 CFR 1910.1025(d)(2) · Lead in general industry
Serious$3,500$2,625Sep 12, 1997Closed
Citation 2, item 2
29 CFR 1910.157(c)(1) · Portable fire extinguishers
Other-than-serious$0$0Sep 12, 1997Closed

Inspection 106627391 OPENED OCT 1, 1992Closed

Complaint · No inspection · Safety · 56 employees at the site · Closed Oct 1, 1992

2600 W 77th St N, Valley Center, KS 67147 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2023, the Valley Center site logged 7 recordable injuries or illnesses among about 102 workers: 6.3 per 100 full-time workers, against a median of 0.7 for its industry. Those cases cost 72 days away from work.

Site and yearWorkersCasesDays-away casesRateIndustry median
National Plastics Color, Inc
Valley Center · 2023
102 756.30.7

Included with any plan: 5 more yearly logs from these sites, back to 2017, with each site's average rate over its latest three years. Already a subscriber? Sign in.

See plans

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1025 · Lead in general industry

29 CFR 1910.1025(d)(2)

(2) Initial determination. Each employer who has a workplace or work operation covered by this standard shall determine if any exployee may be exposed to lead at or above the action level.

29 CFR 1910.110 · Storage and handling of liquefied petroleum gases

29 CFR 1910.110(e)(4)(iii)

(iii) Permanent and removable fuel containers shall be securely mounted to prevent jarring loose, slipping, or rotating, and the fastenings shall be designed and constructed to withstand static loading in any direction equal to twice the weight of the tank and attachments when filled with fuel using a safety factor of not less than four based on the ultimate strength of the material to be used. Field welding, when necessary, shall be made only on saddle plates, lugs or brackets, originally attached to the container by the tank manufacturer.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(f)(5)(i)

(5) Transportation. (i) Chemical manufacturers, importers, or distributors shall ensure that each container of hazardous chemicals leaving the workplace is labeled, tagged, or marked in accordance with this section in a manner which does not conflict with the requirements of the Hazardous Materials Transportation Act (49 U.S.C. 5101 et seq.) and regulations issued under that Act by the Department of Transportation (49 CFR subtitle B).

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.146 · Permit-required confined spaces

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.23 · Guarding floor and wall openings and holes

29 CFR 1910.24 · Fixed industrial stairs

29 CFR 1910.25 · Portable wood ladders

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.334 · Using electrical equipment

29 CFR 1910.36 · Exit route design

29 CFR 1910.37 · Exit routes

29 CFR 1910.95 · Noise

Other all other plastics product manufacturing employers in Kansas

Alert subscribers get notified of each newly cited employer in Kansas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.