OSHA SearchOSHA records by employer

Nationwide Construction Corp.: OSHA inspections and violations

Providence, Rhode Island · New Single-Family Housing Construction (except For-Sale Builders) · NAICS 236115

6inspections
38citation items
$20,065current penalties
Oct 24, 2023last inspection

Since 1994, OSHA inspectors have visited Nationwide Construction Corp. in Rhode Island 6 times.

The most recent inspection opened on Oct 24, 2023 as a planned inspection, in Woonsocket.

In all, OSHA issued 38 citation items: 34 serious and 4 other-than-serious.

The proposed penalties came to $35,907; today they stand at $20,065, 44% less.

The rule cited most here is 1926.451 (scaffolds, general requirements), 7 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Nationwide Construction Corp. averages $4,065 across 1 cited inspection.

Nationwide Construction Corp.: OSHA citation items per year, 1994 to 2023
Citation items per year, by inspection date.

Rhode Island · latest 90 days of OSHA records

81employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in Rhode Island: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Rhode Island

Checking a subcontractor, a client or your own company? Watch Nationwide Construction Corp. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347053522 OPENED OCT 24, 2023Closed

Planned · Complete · Safety · 2 employees at the site · Closed Jul 1, 2024

68-72 S. Main Street, Woonsocket, RI 02895 · New Single-Family Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.403(i)(2)(i) · Electrical equipment on job sites
Other-than-serious$5,807$4,065Feb 9, 2024Final

Inspection 343933396 OPENED APR 16, 2019Closed

Planned · Complete · Safety · 25 employees at the site · Closed Apr 24, 2019

W. Shannock Rd., Richmond, RI 02812 · New Single-Family Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 307574087 OPENED JUL 14, 2005Closed

Referral · Complete · Safety · 6 employees at the site · Closed Aug 18, 2005

620 Main Street, East Greenwich, RI 02818 · New Multifamily Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.501(b)(11) · Fall protection in construction
Serious$3,000$2,000Jul 25, 2005Closed
Citation 1, item 1b
29 CFR 1926.503(a)(1) · Fall protection training in construction
Serious$0$0Jul 25, 2005Closed

Inspection 304990518 OPENED DEC 18, 2002Closed

Planned · Partial · Safety · 28 employees at the site · Closed Dec 3, 2004

44 Mawney Street, Providence, RI 02907 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.153(o) · Liquefied petroleum gas (LP-Gas)
Serious$500$250Jan 14, 2003Closed
Citation 1, item 2
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$2,000$1,000Jan 14, 2003Closed

Inspection 122517196 OPENED MAR 14, 1995Closed

Referral · Complete · Safety · 50 employees at the site · Closed Oct 18, 1995

Bridgham St., Providence, RI 02904 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.20(b)(2) · Construction safety programs
Serious$1,500$900Apr 19, 1995Closed
Citation 1, item 1b
29 CFR 1926.21(b)(2) · Construction safety training
Serious$0$0Apr 19, 1995Closed
Citation 1, item 2a
29 CFR 1926.62(d)(1)(i) · Lead in construction
Serious$2,100$500Apr 19, 1995Closed
Citation 1, item 2e
29 CFR 1926.62(l)(1)(i) · Lead in construction
Serious$0$0Apr 19, 1995Closed
Citation 1, item 3
29 CFR 1926.100(a) · Hard hats in construction
Serious$1,500$900Apr 19, 1995Closed
Citation 1, item 4a
29 CFR 1926.300(b)(1) · Tools—Hand and Power: general requirements
Serious$2,100$1,260Apr 19, 1995Closed
Citation 1, item 4b
29 CFR 1926.304(f) · Woodworking tools
Serious$0$0Apr 19, 1995Closed
Citation 1, item 5
29 CFR 1926.404(b)(1)(i) · Ground-fault protection on job sites
Serious$1,200$720Apr 19, 1995Closed
Citation 1, item 6
29 CFR 1926.416(a)(1) · Electrical safety in construction
Serious$1,500$900Apr 19, 1995Closed
Citation 1, item 7a
29 CFR 1926.451(a)(14) · Scaffolds, general requirements
Serious$1,500$900Apr 19, 1995Closed
Citation 1, item 7b
29 CFR 1926.451(y)(4)(ii) · Scaffolds, general requirements
Serious$0$0Apr 19, 1995Closed
Citation 1, item 7c
29 CFR 1926.451(y)(4)(iii) · Scaffolds, general requirements
Serious$0$0Apr 19, 1995Closed
Citation 1, item 7d
29 CFR 1926.451(y)(11) · Scaffolds, general requirements
Serious$0$0Apr 19, 1995Closed
Citation 1, item 8a
29 CFR 1926.451(m)(3) · Scaffolds, general requirements
Serious$3,000$1,800Apr 19, 1995Closed
Citation 1, item 8b
29 CFR 1926.451(m)(5) · Scaffolds, general requirements
Serious$0$0Apr 19, 1995Closed
Citation 1, item 8c
29 CFR 1926.451(m)(6) · Scaffolds, general requirements
Serious$0$0Apr 19, 1995Closed
Citation 1, item 9a
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$1,200$720Apr 19, 1995Closed
Citation 1, item 9b
29 CFR 1926.550(a)(1) · [Reserved]
Serious$0$0Apr 19, 1995Closed
Citation 1, item 9c
29 CFR 1926.501(b)(14) · Fall protection in construction
Serious$0$0Apr 19, 1995Closed
Citation 1, item 9d
29 CFR 1926.502(i)(3) · Fall protection systems
Serious$0$0Apr 19, 1995Closed
Citation 1, item 9e
29 CFR 1926.502(i)(4) · Fall protection systems
Serious$0$0Apr 19, 1995Closed
Citation 1, item 9f
29 CFR 1926.503(a)(1) · Fall protection training in construction
Serious$0$0Apr 19, 1995Closed
Citation 1, item 10a
29 CFR 1926.501(b)(6) · Fall protection in construction
Serious$1,500$450Apr 19, 1995Closed
Citation 1, item 10b
29 CFR 1926.501(b)(11) · Fall protection in construction
Serious$0$0Apr 19, 1995Closed
Citation 1, item 11a
29 CFR 1926.1053(b)(4) · Ladders in construction
Serious$3,000$1,800Apr 19, 1995Closed
Citation 1, item 11b
29 CFR 1926.1053(b)(6) · Ladders in construction
Serious$0$0Apr 19, 1995Closed
Citation 1, item 11c
29 CFR 1926.1053(b)(16) · Ladders in construction
Serious$0$0Apr 19, 1995Closed
Citation 1, item 11d
29 CFR 1926.1060(a)(1)(iii) · Ladder and stairway training
Serious$0$0Apr 19, 1995Closed
Citation 2, item 1
29 CFR 1926.59(e)(2) · Hazard communication
Serious$3,000$900Apr 19, 1995Closed
Citation 3, item 1
29 CFR 1926.152(a)(1) · Flammable liquids
Other-than-serious$0$0Apr 19, 1995Closed
Citation 3, item 2a
29 CFR 1926.405(a)(2)(iic) · Job-site wiring
Other-than-serious$0$0Apr 19, 1995Closed
Citation 3, item 2b
29 CFR 1926.405(a)(2)(iie) · Job-site wiring
Other-than-serious$0$0Apr 19, 1995Closed

Inspection 122515638 OPENED APR 4, 1994Closed

Unprogrammed related · Partial · Health · 5 employees at the site · Closed Jul 20, 1994

Carpenter House & Podder-miller House, Risd, Providence, RI 02906 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.59(e)(2) · Hazard communication
Serious$1,500$1,000May 5, 1994Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.100 · Hard hats in construction

29 CFR 1926.100(a)

(a) Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, shall be protected by protective helmets.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(16)

(16) Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, shall either be immediately marked in a manner that readily identifies them as defective, or be tagged with “Do Not Use” or similar language, and shall be withdrawn from service until repaired.

29 CFR 1926.1053(b)(4)

(4) Ladders shall be used only for the purpose for which they were designed.

29 CFR 1926.1060 · Ladder and stairway training

29 CFR 1926.152 · Flammable liquids

29 CFR 1926.153 · Liquefied petroleum gas (LP-Gas)

29 CFR 1926.20 · Construction safety programs

29 CFR 1926.21 · Construction safety training

29 CFR 1926.300 · Tools—Hand and Power: general requirements

29 CFR 1926.304 · Woodworking tools

29 CFR 1926.403 · Electrical equipment on job sites

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.416 · Electrical safety in construction

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.502 · Fall protection systems

29 CFR 1926.503 · Fall protection training in construction

29 CFR 1926.550 · [Reserved]

29 CFR 1926.59 · Hazard communication

29 CFR 1926.62 · Lead in construction

Other new single-family housing construction (except for-sale builders) employers in Rhode Island

Alert subscribers get notified of each newly cited employer in Rhode Island the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.