Inspection 348956558 OPENED MAY 26, 2026Closed
589 Balliet Dr, Northampton, PA 18067 · Roofing Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Philadelphia, Pennsylvania · Roofing Contractors · NAICS 238160
OSHA has inspected NE Contractors, Inc. 8 times in Pennsylvania since 2013.
The latest one began on May 26, 2026, in Northampton.
Those inspections ended with 10 citation items: 8 serious, 1 repeat and 1 other-than-serious.
Penalties were first proposed at $43,115 and now stand at $40,667, 6% lower after settlements or reviews.
Fall protection in construction comes up most often in these citations: 5 items under 1926.501.
How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and NE Contractors, Inc. averages $16,478 (2 cited inspections).
Pennsylvania · latest 90 days of OSHA records
287employers cited
30 of them in the same industry
Get notified the morning OSHA posts each new citation in Pennsylvania: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Pennsylvania
Checking a subcontractor, a client or your own company? Watch NE Contractors, Inc. and get notified the morning OSHA posts a new citation for it.
Watch this company589 Balliet Dr, Northampton, PA 18067 · Roofing Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Welsh Road Professional Office Building 2137 Welsh Road, Philadelphia, PA 19115 · Roofing Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.501(b)(10) · Fall protection in construction |
Serious | $7,956 | $7,956 | Aug 20, 2019 | Final |
1000 Buttonwood Street, Philadelphia, PA 19123 · Roofing Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.20(b)(1) · Construction safety programs |
Serious | $3,658 | $3,658 | May 14, 2018 | Final |
| Citation 1, item 2a 29 CFR 1926.501(b)(10) · Fall protection in construction |
Serious | $21,341 | $21,341 | May 14, 2018 | Final |
| Citation 1, item 2b 29 CFR 1926.503(a)(1) · Fall protection training in construction |
Serious | $0 | $0 | May 14, 2018 | Final |
117 Spring Garden Street, Philadelphia, PA 19123 · Roofing Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
953 6th Street, Philadelphia, PA 19123 · Roofing Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Providence Town Center, Collegeville, PA 19426 · Roofing Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.501(b)(10) · Fall protection in construction |
Repeat | $4,000 | $2,800 | Jan 31, 2014 | Final |
| Citation 1, item 2 29 CFR 1926.1053(b)(1) · Ladders in construction |
Serious | $1,360 | $952 | Jan 31, 2014 | Final |
Richards Road, Warminster, PA 18974 · Roofing Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.501(b)(10) · Fall protection in construction |
Serious | $2,000 | $2,000 | Dec 9, 2013 | Final |
2318 North Park Avenue, Philadelphia, PA 19132 · Roofing Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1926.501(b)(10) · Fall protection in construction |
Serious | $2,800 | $1,960 | Apr 8, 2013 | Final |
| Citation 1, item 1b 29 CFR 1926.503(a)(1) · Fall protection training in construction |
Serious | $0 | $0 | Apr 8, 2013 | Final |
| Citation 2, item 1 29 CFR 1926.20(b)(1) · Construction safety programs |
Other-than-serious | $0 | $0 | Apr 8, 2013 | Final |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1926.1053(b)(1)
(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.
29 CFR 1926.20(b)(1)
(b) Accident prevention responsibilities. (1) It shall be the responsibility of the employer to initiate and maintain such programs as may be necessary to comply with this part.
29 CFR 1926.501(b)(10)
(10) Roofing work on Low-slope roofs. Except as otherwise provided in paragraph (b) of this section, each employee engaged in roofing activities on low-slope roofs, with unprotected sides and edges 6 feet (1.8 m) or more above lower levels shall be protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system. Or, on roofs 50-feet (15.25 m) or less in width (see appendix A to subpart M of this part), the use of a safety monitoring system alone [i.e. without the warning line system] is permitted.
Alert subscribers get notified of each newly cited employer in Pennsylvania the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.