OSHA SearchOSHA records by employer

Nelson Precast Products, LLC: OSHA inspections and violations

Baltimore, Maryland · Other Concrete Product Manufacturing · NAICS 327390

2inspections
17citation items
$11,200current penalties
Jun 26, 2017last inspection

Since 2015, OSHA inspectors have visited Nelson Precast Products, LLC in Maryland 2 times.

The most recent inspection opened on Jun 26, 2017 after an accident, in Towson.

In all, OSHA issued 17 citation items: 7 serious and 10 other-than-serious.

The penalties, $11,200 in total, stand where OSHA first set them.

The rule cited most here is 1910.303 (electrical equipment, general requirements), 4 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $4,500 penalty. Nelson Precast Products, LLC averages $5,600 across 2 cited inspections.

The Wage and Hour Division has 1 case on it since 2015, with $261 in back wages owed to workers.

Nelson Precast Products, LLC: OSHA citation items per year, 2015 to 2017
Citation items per year, by inspection date.

Maryland · latest 90 days of OSHA records

187employers cited

Get notified the morning OSHA posts each new citation in Maryland: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Maryland

Checking a subcontractor, a client or your own company? Watch Nelson Precast Products, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342457207 OPENED JUN 26, 2017Closed

Accident · Partial · Safety · 3 employees at the site · Closed Jul 25, 2018

200 Cross Campus Drive, Towson, MD 21204 · Other Concrete Product Manufacturing · OSHA's record · Phone and website on Google Maps

Incident on Jun 27, 2017: Employee falls 15 feet and is injured

At 10:15 a.m. on June 27, 2017, an employee was using a portable jack hammer to chip around pins in a set of concrete steps. As the employee was chipping the concrete in the area around a pin, the stairway system shifted and collapsed. The employee fell approximately 15 feet to a concrete surface below, where sections of the precast stairs fell on his legs. As a result, the employee sustained a right leg fracture from the knee down, abrasions to his right thigh, chipped his front teeth, and experienced neck pain. The employee was hospitalized and treated for his injuries.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$1,800$1,800Nov 16, 2017Final
Citation 1, item 2
29 CFR 1926.503(a)(1) · Fall protection training in construction
Serious$1,800$1,800Nov 16, 2017Final
Citation 1, item 3
29 CFR 1926.850(a) · Preparatory operations
Serious$3,400$3,400Nov 16, 2017Final
Citation 1, item 4a
29 CFR 1926.1052(c)(1)(ii) · Stairways in construction
Serious$2,100$2,100Nov 16, 2017Final
Citation 1, item 4b
29 CFR 1926.1060(a)(1) · Ladder and stairway training
Serious$0$0Nov 16, 2017Final
Citation 2, item 1
29 CFR 1926.503(b)(1) · Fall protection training in construction
Other-than-serious$0$0Nov 16, 2017Final

Inspection 341006443 OPENED OCT 22, 2015Open

Planned · Complete · Safety · 28 employees at the site · Open

2501 W. Lexington Street, Baltimore, MD 21223 · Other Concrete Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.151(c) · First aid and eyewash
Serious$1,050$1,050Jan 20, 2016Final
Citation 1, item 2
29 CFR 1910.243(a)(1)(i) · Guarding of portable powered tools
Serious$1,050$1,050Jan 20, 2016Final
Citation 2, item 1
29 CFR 1910.22(a)(1) · General requirements
Other-than-serious$0$0Jan 20, 2016Final
Citation 2, item 2
29 CFR 1910.24(h) · Fixed industrial stairs
Other-than-serious$0$0Jan 20, 2016Final
Citation 2, item 3
29 CFR 1910.178(l)(6) · Forklifts and other powered industrial trucks
Other-than-serious$0$0Jan 20, 2016Final
Citation 2, item 4
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Other-than-serious$0$0Jan 20, 2016Final
Citation 2, item 5
29 CFR 1910.303(e)(1)(i) · Electrical equipment, general requirements
Other-than-serious$0$0Jan 20, 2016Final
Citation 2, item 6
29 CFR 1910.303(e)(1)(ii) · Electrical equipment, general requirements
Other-than-serious$0$0Jan 20, 2016Final
Citation 2, item 7
29 CFR 1910.303(f)(2) · Electrical equipment, general requirements
Other-than-serious$0$0Jan 20, 2016Final
Citation 2, item 8
29 CFR 1910.305(b)(1)(i) · Electrical wiring methods
Other-than-serious$0$0Jan 20, 2016Final
Citation 2, item 9
29 CFR 1910.305(g)(1)(iv)(a) · Electrical wiring methods
Other-than-serious$0$0Jan 20, 2016Final

Wage and hour cases

Cases by the Labor Department's Wage and Hour Division since 2015: unpaid minimum wage or overtime, child labor, family leave and more.

Period reviewedViolationsWorkers owedBack wagesPenalties
Mar 1, 2016 to Feb 28, 2018
Baltimore
71$261$49,486

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.151 · First aid and eyewash

29 CFR 1910.151(c)

(c) Where the eyes or body of any person may be exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body shall be provided within the work area for immediate emergency use.

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.178(l)(6)

(6) Certification. The employer shall certify that each operator has been trained and evaluated as required by this paragraph (l). The certification shall include the name of the operator, the date of the training, the date of the evaluation, and the identity of the person(s) performing the training or evaluation.

29 CFR 1910.22 · General requirements

29 CFR 1910.24 · Fixed industrial stairs

29 CFR 1910.243 · Guarding of portable powered tools

29 CFR 1910.243(a)(1)(i)

(a) Portable powered tool—(1) Portable circular saws. (i) All portable, power-driven circular saws having a blade diameter greater than 2 in. shall be equipped with guards above and below the base plate or shoe. The upper guard shall cover the saw to the depth of the teeth, except for the minimum arc required to permit the base to be tilted for bevel cuts. The lower guard shall cover the saw to the depth of the teeth, except for the minimum arc required to allow proper retraction and contact with the work. When the tool is withdrawn from the work, the lower guard shall automatically and instantly return to covering position.

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1926.1052 · Stairways in construction

29 CFR 1926.1060 · Ladder and stairway training

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.503 · Fall protection training in construction

29 CFR 1926.850 · Preparatory operations

Other other concrete product manufacturing employers in Maryland

Alert subscribers get notified of each newly cited employer in Maryland the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.