OSHA SearchOSHA records by employer

Nice Electric Co: OSHA inspections and violations

Mcminnville, Oregon · Electrical Contractors and Other Wiring Installation Contractors · NAICS 238210

8inspections
14citation items
$100current penalties
Feb 6, 2024last inspection

Since 1990, OSHA inspectors have visited Nice Electric Co in Oregon 8 times.

The most recent inspection opened on Feb 6, 2024 as a planned inspection.

In all, OSHA issued 14 citation items: 14 other-than-serious.

The penalties, $100 in total, stand where OSHA first set them.

The rule cited most here is 1926.59 (hazard communication), 4 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Nice Electric Co averages $100 across 1 cited inspection.

Nice Electric Co: OSHA citation items per year, 1990 to 2024
Citation items per year, by inspection date.

Oregon · latest 90 days of OSHA records

384employers cited

5 of them in the same industry

Get notified the morning OSHA posts each new citation in Oregon: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Oregon

Checking a subcontractor, a client or your own company? Watch Nice Electric Co and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347261547 OPENED FEB 6, 2024Closed

Planned · Partial · Safety · 1 employee at the site · Closed Jun 25, 2024

480 Sw Oregon Falls Dr, , OR 97338 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR OAR 437-001-0700(14)(A)-2
Other-than-serious$100$100Mar 18, 2024Final

Inspection 310639299 OPENED JAN 17, 2007Closed

Planned · Partial · Safety · 1 employee at the site · Closed Jun 19, 2007

1894 Nw Yohn Ranch, Mcminnville, OR 97128 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.405(g)(2)(iv) · Job-site wiring
Other-than-serious$0$0Feb 22, 2007Closed
Citation 1, item 2
29 CFR 1926.404(f)(6) · Ground-fault protection on job sites
Other-than-serious$0$0Feb 22, 2007Closed

Inspection 310639471 OPENED JAN 5, 2007Closed

Planned · Complete · Safety · 18 employees at the site · Closed Jun 19, 2007

1605 Ne Riverside Dr, Mcminnville, OR 97128 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Other-than-serious$0$0Feb 12, 2007Closed
Citation 1, item 2
29 CFR 1910.178(l)(6) · Forklifts and other powered industrial trucks
Other-than-serious$0$0Feb 12, 2007Closed
Citation 1, item 3 Other-than-serious$0$0Feb 12, 2007Closed
Citation 1, item 4
29 CFR 1926.59(e)(1) · Hazard communication
Other-than-serious$0$0Feb 12, 2007Closed

Inspection 310638853 OPENED DEC 21, 2006Closed

Planned · Complete · Safety · 1 employee at the site · Closed Jan 8, 2007

1884 Parkmeadow Ave, Monmouth, OR 97361 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 308458884 OPENED JUL 11, 2005Closed

Accident · Partial · Safety · 15 employees at the site · Closed May 19, 2006

1300 Ne Alpha Dr, Mcminnville, OR 97128 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Incident on Jul 7, 2005: Employee burned by arc flash in servicing circuit breaker

At approximately 2:00 p.m. on July 7, 2005, Employee #1 was replacing portions o f a panel cover. The work entailed removing the cover panel of a 277/480-volt li ve main service to inspect the breaker attachment configuration and then replaci ng the existing 100-amp breaker with a new 200-amp breaker. While he was working , there was an arc flash. Employee #1 sustained burns, for which he required hos pitalization.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a Other-than-serious$0$0Sep 9, 2005Closed
Citation 1, item 1b Other-than-serious$0$0Sep 9, 2005Closed
Citation 1, item 2 Other-than-serious$0$0Sep 9, 2005Closed

Inspection 126701580 OPENED MAY 28, 1996Closed

Planned · Complete · Safety · 3 employees at the site · Closed May 9, 1997

906 Deborah Rd, Newberg, OR 97132 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.404(f)(7)(ivc) · Ground-fault protection on job sites
Other-than-serious$0$0Jun 27, 1996Closed

Inspection 115705899 OPENED FEB 11, 1992Closed

Planned · Complete · Safety · 2 employees at the site · Closed Apr 20, 1992

411 3rd St, Mcminnville, OR 97128 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.59(e)(1) · Hazard communication
Other-than-serious$0$0Mar 3, 1992Closed
Citation 1, item 2
29 CFR 1926.59(g)(1) · Hazard communication
Other-than-serious$0$0Mar 3, 1992Closed
Citation 1, item 3
29 CFR 1926.59(h) · Hazard communication
Other-than-serious$0$0Mar 3, 1992Closed

Inspection 108225269 OPENED MAY 24, 1990Closed

Planned · Complete · Safety · 1 employee at the site · Closed May 24, 1990

Delphian School Sw Roack Creek Rd, Sheridan, OR 97378 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.178(l)(6)

(6) Certification. The employer shall certify that each operator has been trained and evaluated as required by this paragraph (l). The certification shall include the name of the operator, the date of the training, the date of the evaluation, and the identity of the person(s) performing the training or evaluation.

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.404(f)(6)

(6) Grounding path. The path to ground from circuits, equipment, and enclosures shall be permanent and continuous.

29 CFR 1926.404(f)(7)(ivc)

(C) If the equipment is one of the types listed in paragraphs (f)(7)(iv)(C)(1) through (f)(7)(iv)(C)(5) of this section. However, even though the equipment may be one of these types, it need not be grounded if it is exempted by paragraph (f)(7)(iv)(C)(6).

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.59 · Hazard communication

29 CFR 7010.7650

29 CFR 7020.1380

29 CFR 7030.5030

Other electrical contractors and other wiring installation contractors employers in Oregon

Alert subscribers get notified of each newly cited employer in Oregon the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.