OSHA SearchOSHA records by employer

Norstam Veneers, Inc: OSHA inspections and violations

Mauckport, Indiana · Hardwood Veneer and Plywood Manufacturing · NAICS 321211

7inspections
50citation items
$19,815current penalties
Oct 22, 2025last inspection

OSHA has inspected Norstam Veneers, Inc 7 times in Indiana since 1982.

The latest one began on Oct 22, 2025 after a complaint, in Mauckport.

Those inspections ended with 50 citation items: 27 serious, 1 repeat and 22 other-than-serious.

Penalties were first proposed at $32,650 and now stand at $19,815, 39% lower after settlements or reviews.

Woodworking machinery comes up most often in these citations: 8 items under 1910.213.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $4,500, and Norstam Veneers, Inc averages $10,500 (1 cited inspection).

1 inspection on this page followed a fatal incident.

Norstam Veneers, Inc: OSHA citation items per year, 1982 to 2025
Citation items per year, by inspection date.

Indiana · latest 90 days of OSHA records

81employers cited

Get notified the morning OSHA posts each new citation in Indiana: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Indiana

Checking a subcontractor, a client or your own company? Watch Norstam Veneers, Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348565177 OPENED OCT 22, 2025Closed

Complaint · Partial · Safety · 65 employees at the site · Closed May 11, 2026

2990 Overlook Drive Southwest, Mauckport, IN 47142 · Hardwood Veneer and Plywood Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.147(c)(1) · Lockout/tagout
Serious$4,200$4,200Mar 23, 2026Final
Citation 1, item 2
29 CFR 1910.165(b)(1) · Employee alarm systems
Serious$900$900Mar 23, 2026Final
Citation 1, item 3
29 CFR 1910.213(r)(4) · Woodworking machinery
Serious$1,800$1,800Mar 23, 2026Final
Citation 1, item 4
29 CFR 1910.242(b) · Hand and power tools
Serious$2,700$2,700Mar 23, 2026Final
Citation 1, item 5
29 CFR 1910.303(g)(1)(i) · Electrical equipment, general requirements
Serious$900$900Mar 23, 2026Final

Inspection 305638603 OPENED NOV 14, 2002Closed

Planned · Complete · Safety · 134 employees at the site · Closed Mar 6, 2003

2990 Overlook Drive, Mauckport, IN 47142 · Hardwood Veneer and Plywood Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.23(a)(5) · Guarding floor and wall openings and holes
Serious$1,750$685Jan 15, 2003Closed
Citation 1, item 2
29 CFR 1910.38(a)(1) · Emergency action plans
Serious$1,400$550Jan 15, 2003Closed
Citation 1, item 3
29 CFR 1910.212(a)(1) · Machine guarding
Serious$1,400$550Jan 15, 2003Closed
Citation 1, item 4
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$1,750$100Jan 15, 2003Closed
Citation 1, item 5
29 CFR 1910.212(a)(5) · Machine guarding
Serious$1,400$550Jan 15, 2003Closed
Citation 1, item 6
29 CFR 1910.213(i)(1) · Woodworking machinery
Other-than-serious$1,400$0Jan 15, 2003Closed
Citation 1, item 7
29 CFR 1910.213(q)(2) · Woodworking machinery
Serious$1,750$685Jan 15, 2003Closed
Citation 1, item 8a
29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts
Serious$1,400$550Jan 15, 2003Closed
Citation 1, item 8b
29 CFR 1910.219(e)(3)(i) · Belts, pulleys and power-transmission parts
Serious$0$0Jan 15, 2003Closed
Citation 2, item 1
29 CFR 4000402
Other-than-serious$0$0Jan 15, 2003Closed
Citation 2, item 2
29 CFR 1910.23(d)(1)(iv) · Guarding floor and wall openings and holes
Other-than-serious$0$0Jan 15, 2003Closed
Citation 2, item 3
29 CFR 1910.132(a) · Personal protective equipment, general requirements
Other-than-serious$0$0Jan 15, 2003Closed
Citation 2, item 4
29 CFR 1910.178(p)(1) · Forklifts and other powered industrial trucks
Other-than-serious$0$0Jan 15, 2003Closed
Citation 2, item 5
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Other-than-serious$0$0Jan 15, 2003Closed
Citation 2, item 6
29 CFR 1910.303(f) · Electrical equipment, general requirements
Other-than-serious$0$0Jan 15, 2003Closed
Citation 2, item 7
29 CFR 1910.305(b)(2) · Electrical wiring methods
Other-than-serious$0$0Jan 15, 2003Closed

Inspection 114969827 OPENED JUN 19, 1997Closed

Accident · Complete · Safety · 119 employees at the site · Closed Sep 24, 1997

2990 Overlook Drive, Mauckport, IN 47142 · OSHA's record · Phone and website on Google Maps

Incident on Jun 18, 1997 (fatal): Employee killed when board kicks back from edger

At approximately 2:00 p.m. on June 18, 1997, Employee #1 was off-loading boards from the head saw in a veneer mill and operating a Corley E535 edger, serial #E- 536-046. He was operating the laser beam adjustments and entering boards into th e edger. An 18 in. wide by 17 ft long by 1 in. thick board ran in through the an ti-kickback fingers and through the feed rolls, but a buttswell knot caught on t he right vertical structure of the edger opening and the board became caught. Em ployee #1, who apparently had been instructed to shut the machine off and manual ly remove stuck boards, instead used the next board to push, butt, and force the stuck board through the opening. The second board suddenly rode up onto the top of the first board and went on through the kickback fingers, which now were int act on that board. When Employee #1 freed up the feed rolls, the 18 in. saw blad e threw the first board back down the entire length of the edger feed table and into his right ribs. He suffered a bruised right lung and a severely lacerated l iver and died of massive internal hemorrhaging. Subsequent interviews and statem ents confirmed that other operators did the same thing to free up boards, and th at there were no JSA, SJP, or SOP written procedures for such occurrences. Emplo yee #1 had previously worked for the company for approximately 1 1/2 years and h ad just been rehired on May 29, 1997 after a three-year hiatus.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Serious$2,750$2,060Aug 12, 1997Closed
Citation 1, item 2
29 CFR 1910.23(d)(1)(ii) · Guarding floor and wall openings and holes
Serious$825$410Aug 12, 1997Closed
Citation 1, item 3
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Serious$1,100$550Aug 12, 1997Closed
Citation 1, item 4
29 CFR 1910.303(g)(2)(i) · Electrical equipment, general requirements
Serious$1,375$685Aug 12, 1997Closed
Citation 1, item 5
29 CFR 1910.304(f)(4) · Grounding and circuit protection
Serious$1,100$410Aug 12, 1997Closed
Citation 2, item 1
29 CFR 1910.37(k)(2) · Exit routes
Other-than-serious$0$0Aug 12, 1997Closed
Citation 2, item 2
29 CFR 1910.179(n)(4)(i) · Overhead and gantry cranes
Other-than-serious$0$0Aug 12, 1997Closed
Citation 2, item 3
29 CFR 1910.213(b)(6) · Woodworking machinery
Other-than-serious$0$0Aug 12, 1997Closed
Citation 2, item 4
29 CFR 1910.305(g)(2)(ii) · Electrical wiring methods
Other-than-serious$0$0Aug 12, 1997Closed

Inspection 114962509 OPENED APR 21, 1992Closed

Planned · Complete · Safety · 83 employees at the site · Closed Aug 5, 1992

2990 Overlook Drive, Mauckport, IN 47142 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.213(h)(1) · Woodworking machinery
Serious$625$350Jun 18, 1992Closed
Citation 1, item 1b
29 CFR 1910.213(h)(3) · Woodworking machinery
Serious$0$0Jun 18, 1992Closed
Citation 1, item 1c
29 CFR 1910.213(h)(4) · Woodworking machinery
Serious$0$0Jun 18, 1992Closed
Citation 1, item 2
29 CFR 1910.303(g)(2)(i) · Electrical equipment, general requirements
Serious$625$350Jun 18, 1992Closed
Citation 1, item 3
29 CFR 1910.304(f)(4) · Grounding and circuit protection
Serious$500$300Jun 18, 1992Closed
Citation 2, item 1
29 CFR 1910.178(p)(1) · Forklifts and other powered industrial trucks
Other-than-serious$0$0Jun 18, 1992Closed
Citation 2, item 2
29 CFR 1910.334(a)(2)(ii) · Using electrical equipment
Other-than-serious$0$0Jun 18, 1992Closed

Inspection 2689438 OPENED NOV 25, 1985Closed

Planned · Complete · Safety · 45 employees at the site · Closed Dec 31, 1985

Sr135 & Overlook Dr, Mauckport, IN 47142 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.23(a)(3) · Guarding floor and wall openings and holes
Serious$120$120Dec 2, 1985Closed
Citation 2, item 1
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Other-than-serious$0$0Dec 2, 1985Closed
Citation 2, item 2
29 CFR 1910.305(g)(1)(iii) · Electrical wiring methods
Other-than-serious$0$0Dec 2, 1985Closed

Inspection 215197484 OPENED SEP 19, 1983Closed

Planned · Complete · Safety · 41 employees at the site · Closed Nov 4, 1983

Hwy 135 & Overlook Drive, Mauckport, IN 47142 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.213(q)(2) · Woodworking machinery
Serious$160$160Sep 26, 1983Closed
Citation 2, item 1
29 CFR 1910.215(a)(2) · Grinders and abrasive wheels
Other-than-serious$0$0Sep 26, 1983Closed
Citation 2, item 2
29 CFR 1910.252(b)(3)(iiia) · Welding fire safety
Other-than-serious$0$0Sep 26, 1983Closed

Inspection 215209206 OPENED SEP 27, 1982Closed

Planned · Complete · Safety · 35 employees at the site · Closed Dec 15, 1982

1 1/2 Mi N Mauckport On Hwy135, Mauckport, IN 47142 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts
Serious$240$200Oct 28, 1982Closed
Citation 1, item 1b
29 CFR 1910.219(e)(3)(i) · Belts, pulleys and power-transmission parts
Serious$0$0Oct 7, 1982Closed
Citation 2, item 1 Repeat$480$50Oct 28, 1982Closed
Citation 3, item 1
29 CFR 1910.37(q)(1) · Exit routes
Other-than-serious$0$0Oct 7, 1982Closed
Citation 3, item 2
29 CFR 1910.38(a)(1) · Emergency action plans
Other-than-serious$0$0Oct 7, 1982Closed
Citation 3, item 3
29 CFR 1910.165(b)(1) · Employee alarm systems
Other-than-serious$0$0Oct 7, 1982Closed
Citation 3, item 4
29 CFR 1910.303(f) · Electrical equipment, general requirements
Other-than-serious$0$0Oct 7, 1982Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.132(a)

(a) Application. Protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, shall be provided, used, and maintained in a sanitary and reliable condition wherever it is necessary by reason of hazards of processes or environment, chemical hazards, radiological hazards, or mechanical irritants encountered in a manner capable of causing injury or impairment in the function of any part of the body through absorption, inhalation or physical contact.

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.147(c)(1)

(c) General—(1) Energy control program. The employer shall establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, start up or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source, and rendered inoperative.

29 CFR 1910.165 · Employee alarm systems

29 CFR 1910.165(b)(1)

(b) General requirements. (1) The employee alarm system shall provide warning for necessary emergency action as called for in the emergency action plan, or for reaction time for safe escape of employees from the workplace or the immediate work area, or both.

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.179 · Overhead and gantry cranes

29 CFR 1910.212 · Machine guarding

29 CFR 1910.213 · Woodworking machinery

29 CFR 1910.215 · Grinders and abrasive wheels

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.23 · Guarding floor and wall openings and holes

29 CFR 1910.242 · Hand and power tools

29 CFR 1910.252 · Welding fire safety

29 CFR 1910.265 · Sawmills

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.334 · Using electrical equipment

29 CFR 1910.37 · Exit routes

29 CFR 1910.38 · Emergency action plans

29 CFR 2200.801

Other hardwood veneer and plywood manufacturing employers in Indiana

Alert subscribers get notified of each newly cited employer in Indiana the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.