OSHA SearchOSHA records by employer

North State Steel, Inc.: OSHA inspections and violations

Greenville, North Carolina · Fabricated Structural Metal Manufacturing · NAICS 332312

10inspections
25citation items
$2,010current penalties
Aug 30, 2024last inspection

OSHA has inspected North State Steel, Inc. 10 times in North Carolina since 1984.

The latest one began on Aug 30, 2024 after a fatality or catastrophe, in Louisburg.

Those inspections ended with 25 citation items: 1 serious and 24 other-than-serious.

Penalties were first proposed at $2,161 and now stand at $2,010, 7% lower after settlements or reviews.

Respiratory protection comes up most often in these citations: 4 items under 1910.134.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and North State Steel, Inc. averages $900 (1 cited inspection).

1 inspection on this page followed a fatal incident.

North State Steel, Inc. also files yearly injury logs with OSHA, summarized below.

The Wage and Hour Division has 1 case on it since 2015, with $0 in back wages owed to workers.

North State Steel, Inc.: OSHA citation items per year, 1984 to 2024
Citation items per year, by inspection date.

North Carolina · latest 90 days of OSHA records

234employers cited

Get notified the morning OSHA posts each new citation in North Carolina: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in North Carolina

Checking a subcontractor, a client or your own company? Watch North State Steel, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347726515 OPENED AUG 30, 2024Closed

Fatality or catastrophe · Partial · Health · 18 employees at the site · Closed Feb 13, 2025

1801 Nc Hwy 98 W, Louisburg, NC 27549 · Fabricated Structural Metal Manufacturing · OSHA's record · Phone and website on Google Maps

Incident on Aug 29, 2024 (fatal): Employee is found unresponsive after complaining of chest pa

At 12:00 a.m. on August 29, 2024, Employee #1, a material handler at a steel fabrication facility, was taking his morning break in the breakroom. Upon returning to work after the break, he began complaining of trouble breathing and chest pain. He called 911, and a coworker remained with him until EMS arrived on scene. When EMS arrived, the employee was found unconscious, and CPR was initiated. The employee was transported to the hospital but was pronounced dead later that night due to a preexisting medical condition. The incident was determined not to be work-related.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.134(e)(1) · Respiratory protection
Other-than-serious$900$900Feb 7, 2025Final
Citation 1, item 1b
29 CFR 1910.134(f)(2) · Respiratory protection
Other-than-serious$0$0Feb 7, 2025Final
Citation 1, item 1c
29 CFR 1910.134(g)(1)(i)(a) · Respiratory protection
Other-than-serious$0$0Feb 7, 2025Final
Citation 1, item 2
29 CFR 1910.305(g)(1)(iv)(a) · Electrical wiring methods
Other-than-serious$0$0Feb 7, 2025Final

Inspection 344225180 OPENED JUL 25, 2019Closed

Fatality or catastrophe · No inspection · Safety · Closed Jul 30, 2019

1010 W Gum Road, Greenville, NC 27834 · Fabricated Structural Metal Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 311339675 OPENED SEP 24, 2007Closed

Planned · Complete · Health · 16 employees at the site · Closed Dec 21, 2007

1801 Nc Hwy 98 West, Louisburg, NC 27549 · Fabricated Structural Metal Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.179(j)(3) · Overhead and gantry cranes
Other-than-serious$250$250Oct 29, 2007Closed
Citation 1, item 2
29 CFR 1910.304(g)(5) · Grounding and circuit protection
Other-than-serious$250$250Oct 29, 2007Closed
Citation 2, item 1 Other-than-serious$100$100Oct 29, 2007Closed
Citation 2, item 2
29 CFR 1910.134(c)(2)(i) · Respiratory protection
Other-than-serious$0$0Oct 29, 2007Closed
Citation 2, item 3
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Other-than-serious$0$0Oct 29, 2007Closed

Inspection 310499546 OPENED DEC 1, 2006Closed

Planned · Complete · Safety · 27 employees at the site · Closed May 15, 2007

1010 W Gum Street, Greenville, NC 27834 · Fabricated Structural Metal Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.23(c)(1) · Guarding floor and wall openings and holes
Other-than-serious$88$0Dec 12, 2006Closed
Citation 1, item 2
29 CFR 1910.22(d)(1) · General requirements
Other-than-serious$63$0Dec 12, 2006Closed
Citation 2, item 1
29 CFR 1910.303(g)(1)(i) · Electrical equipment, general requirements
Other-than-serious$0$0Dec 12, 2006Closed
Citation 2, item 2
29 CFR 1910.305(g)(1)(iii) · Electrical wiring methods
Other-than-serious$0$0Dec 12, 2006Closed
Citation 2, item 3
29 CFR 1910.334(b)(2) · Using electrical equipment
Other-than-serious$0$0Dec 12, 2006Closed

Inspection 308546753 OPENED MAR 15, 2005Closed

Planned · Records only · Health · 16 employees at the site · Closed Mar 28, 2005

1801 Nc Hwy 98 West, Louisburg, NC 27549 · Fabricated Structural Metal Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 308546688 OPENED JAN 26, 2005Closed

Planned · Records only · Health · 26 employees at the site · Closed Mar 28, 2005

1010 W Gum Street, Greenville, NC 27834 · Fabricated Structural Metal Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1904.2(a) · Partial exemption for establishments in certain industries
Other-than-serious$300$300Feb 4, 2005Closed
Citation 1, item 2
29 CFR 1910.1200(e)(1)(i) · Hazard communication
Other-than-serious$0$0Feb 4, 2005Closed

Inspection 305409682 OPENED JUN 3, 2002Closed

Planned · Complete · Safety · 42 employees at the site · Closed Jun 26, 2002

1100 Red Banks Road, Greenville, NC 27858 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.350(h) · Gas welding and cutting
Other-than-serious$0$0Jun 6, 2002Closed

Inspection 3055894 OPENED SEP 20, 1988Closed

Follow-up · No inspection · Safety · Closed Sep 20, 1988

Highways 11 & 13 North, Greenville, NC 27834 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

2 older inspections

Inspection 3023116 OPENED JAN 23, 1986Closed

Unprogrammed related · Complete · Safety · 6 employees at the site · Closed Jan 6, 1989

Highways 11&13 North, Greenville, NC 27834 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.28(a) · Personal protective equipment
Serious$210$210Mar 17, 1986Closed
Citation 2, item 1
29 CFR 1926.25(a) · Housekeeping
Other-than-serious$0$0Mar 17, 1986Closed
Citation 2, item 2
29 CFR 1926.150(a)(4) · Fire protection
Other-than-serious$0$0Mar 17, 1986Closed
Citation 2, item 3
29 CFR 1926.152(g)(9) · Flammable liquids
Other-than-serious$0$0Mar 17, 1986Closed
Citation 2, item 4
29 CFR 1926.152(g)(11) · Flammable liquids
Other-than-serious$0$0Mar 17, 1986Closed
Citation 2, item 5 Other-than-serious$0$0Mar 17, 1986Closed
Citation 2, item 6
29 CFR 1926.450(a)(10) · Scope, application and definitions applicable to this subpart
Other-than-serious$0$0Mar 17, 1986Closed
Citation 2, item 7
29 CFR 1926.500(b)(7) · Scope, application, and definitions applicable to this subpart
Other-than-serious$0$0Mar 17, 1986Closed

Inspection 14984215 OPENED MAY 16, 1984Closed

Planned · Complete · Safety · 3 employees at the site · Closed May 17, 1984

1300 Charles Blvd, Greenville, NC 27834 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2024, the Greenville site logged 2 recordable injuries or illnesses among about 75 workers: 2.8 per 100 full-time workers, against a median of 3.6 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
Greenville site
Greenville · 2024
75 202.83.6
Louisburg site
Louisburg · 2024
19 104.63.6

Included with any plan: 15 more yearly logs from these sites, back to 2016, with each site's average rate over its latest three years. Already a subscriber? Sign in.

See plans

Wage and hour cases

Cases by the Labor Department's Wage and Hour Division since 2015: unpaid minimum wage or overtime, child labor, family leave and more.

Period reviewedViolationsWorkers owedBack wagesPenalties
Jan 13, 2026 to Mar 24, 2026
Louisburg
30$0$36,079

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1904.2 · Partial exemption for establishments in certain industries

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(e)(1)(i)

(i) A list of the hazardous chemicals known to be present using a product identifier that is referenced on the appropriate safety data sheet (the list may be compiled for the workplace as a whole or for individual work areas); and,

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.134(c)(2)(i)

(i) An employer may provide respirators at the request of employees or permit employees to use their own respirators, if the employer determines that such respirator use will not in itself create a hazard. If the employer determines that any voluntary respirator use is permissible, the employer shall provide the respirator users with the information contained in appendix D to this section (“Information for Employees Using Respirators When Not Required Under the Standard”); and

29 CFR 1910.134(e)(1)

(1) General. The employer shall provide a medical evaluation to determine the employee's ability to use a respirator, before the employee is fit tested or required to use the respirator in the workplace. The employer may discontinue an employee's medical evaluations when the employee is no longer required to use a respirator.

29 CFR 1910.179 · Overhead and gantry cranes

29 CFR 1910.22 · General requirements

29 CFR 1910.23 · Guarding floor and wall openings and holes

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.334 · Using electrical equipment

29 CFR 1910.95 · Noise

29 CFR 1926.150 · Fire protection

29 CFR 1926.152 · Flammable liquids

29 CFR 1926.25 · Housekeeping

29 CFR 1926.28 · Personal protective equipment

29 CFR 1926.350 · Gas welding and cutting

29 CFR 1926.400 · Introduction

29 CFR 1926.450 · Scope, application and definitions applicable to this subpart

29 CFR 1926.500 · Scope, application, and definitions applicable to this subpart

Other fabricated structural metal manufacturing employers in North Carolina

Alert subscribers get notified of each newly cited employer in North Carolina the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.