OSHA SearchOSHA records by employer

Northwest Door and Supply Inc: OSHA inspections and violations

Tualatin, Oregon · Wood Window and Door Manufacturing · NAICS 321911

8inspections
44citation items
$7,335current penalties
Aug 11, 2016last inspection

Since 1986, OSHA inspectors have visited Northwest Door and Supply Inc in Oregon 8 times.

The most recent inspection opened on Aug 11, 2016 as a planned inspection, in Tualatin.

In all, OSHA issued 44 citation items: 22 serious and 22 other-than-serious.

The proposed penalties came to $8,415; today they stand at $7,335, 13% less.

The rule cited most here is 1910.213 (woodworking machinery), 7 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $4,500 penalty. Northwest Door and Supply Inc averages $1,980 across 1 cited inspection.

Northwest Door and Supply Inc: OSHA citation items per year, 1986 to 2016
Citation items per year, by inspection date.

Oregon · latest 90 days of OSHA records

385employers cited

Get notified the morning OSHA posts each new citation in Oregon: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Oregon

Checking a subcontractor, a client or your own company? Watch Northwest Door and Supply Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341693166 OPENED AUG 11, 2016Closed

Planned · Complete · Safety · 31 employees at the site · Closed Mar 8, 2017

10550 Sw Manhasset Dr, Tualatin, OR 97062 · Wood Window and Door Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.333(a) · Working near live electrical parts
Serious$2,100$1,260Sep 30, 2016Final
Citation 1, item 2
29 CFR 1910.147(c)(1) · Lockout/tagout
Serious$300$180Sep 30, 2016Final
Citation 1, item 3
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Serious$180$180Sep 30, 2016Final
Citation 1, item 4
29 CFR 1910.242(b) · Hand and power tools
Serious$180$180Sep 30, 2016Final
Citation 1, item 5
29 CFR OAR 437-001-0765(1)
Serious$300$180Sep 30, 2016Final
Citation 2, item 6
29 CFR 1910.303(f)(2) · Electrical equipment, general requirements
Other-than-serious$0$0Sep 30, 2016Final
Citation 2, item 7
29 CFR OAR 437-002-0378(4)(A)
Other-than-serious$0$0Sep 30, 2016Final

Inspection 314968108 OPENED OCT 15, 2010Closed

Planned · Complete · Safety · 25 employees at the site · Closed Mar 21, 2011

10550 Sw Manhasset Dr, Tualatin, OR 97062 · Wood Window and Door Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.213(c)(3) · Woodworking machinery
Serious$275$275Nov 8, 2010Closed
Citation 1, item 2
29 CFR 1910.213(c)(2) · Woodworking machinery
Serious$275$275Nov 8, 2010Closed
Citation 1, item 3 Serious$275$275Nov 8, 2010Closed
Citation 1, item 4 Serious$165$165Nov 8, 2010Closed
Citation 2, item 5
29 CFR 1910.305(b)(2)(i) · Electrical wiring methods
Other-than-serious$0$0Nov 8, 2010Closed

Inspection 311172688 OPENED SEP 12, 2007Closed

Follow-up · Partial · Safety · 71 employees at the site · Closed Sep 12, 2007

10550 Sw Manhasset Dr, Tualatin, OR 97062 · Wood Window and Door Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 310684568 OPENED FEB 15, 2007Closed

Planned · Complete · Safety · 71 employees at the site · Closed Feb 4, 2008

10550 Sw Manhasset Dr, Tualatin, OR 97062 · Wood Window and Door Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.213(c)(2) · Woodworking machinery
Serious$325$325Jun 26, 2007Closed
Citation 1, item 1b
29 CFR 1910.213(c)(3) · Woodworking machinery
Serious$0$0Jun 26, 2007Closed
Citation 1, item 2
29 CFR 1910.213(h)(1) · Woodworking machinery
Serious$325$325Jun 26, 2007Closed
Citation 1, item 3
29 CFR 1910.242(b) · Hand and power tools
Serious$105$105Jun 26, 2007Closed
Citation 2, item 4 Other-than-serious$0$0Jun 26, 2007Closed
Citation 2, item 5 Other-than-serious$0$0Jun 26, 2007Closed
Citation 2, item 6 Other-than-serious$0$0Jun 26, 2007Closed
Citation 2, item 7
29 CFR 1910.178(l)(2)(ii) · Forklifts and other powered industrial trucks
Other-than-serious$0$0Jun 26, 2007Closed
Citation 2, item 8
29 CFR 1910.178(l)(4)(iii) · Forklifts and other powered industrial trucks
Other-than-serious$0$0Jun 26, 2007Closed

Inspection 307826313 OPENED JUN 25, 2004Closed

Complaint · Partial · Safety · 4 employees at the site · Closed Jan 12, 2005

148th & E Burnside St, Portland, OR 97214 · Wood Window and Door Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Serious$1,750$1,750Jul 26, 2004Closed
Citation 1, item 2
29 CFR 1926.100(a) · Hard hats in construction
Serious$210$210Jul 26, 2004Closed
Citation 1, item 3 Serious$300$300Jul 26, 2004Closed

Inspection 304816614 OPENED JAN 28, 2002Closed

Planned · Complete · Safety · 55 employees at the site · Closed May 19, 2003

10550 Sw Manhasset Dr, Tualatin, OR 97062 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Serious$100$100Mar 6, 2002Closed
Citation 2, item 2
29 CFR 1910.157(c)(1) · Portable fire extinguishers
Other-than-serious$0$0Mar 6, 2002Closed
Citation 2, item 3
29 CFR 1910.1200(e)(1)(i) · Hazard communication
Other-than-serious$0$0Mar 6, 2002Closed
Citation 2, item 4 Other-than-serious$0$0Mar 6, 2002Closed

Inspection 108267980 OPENED JUL 31, 1990Closed

Planned · Complete · Safety · 53 employees at the site · Closed Oct 5, 1990

16358 Sw 72nd, Tigard, OR 97223 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.213(n)(1) · Woodworking machinery
Serious$500$500Aug 23, 1990Closed
Citation 1, item 2
29 CFR 7620600
Serious$150$150Aug 23, 1990Closed
Citation 1, item 3
29 CFR 1910.213(h)(1) · Woodworking machinery
Serious$350$350Aug 23, 1990Closed
Citation 1, item 4
29 CFR 1910.219(e)(5)(i) · Belts, pulleys and power-transmission parts
Serious$105$105Aug 23, 1990Closed
Citation 2, item 5 Other-than-serious$100$100Aug 23, 1990Closed

Inspection 105218341 OPENED SEP 17, 1986Closed

Planned · Complete · Safety · 43 employees at the site · Closed Dec 5, 1986

16358 Sw 72nd, Tigard, OR 97224 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 7640140
Serious$45$45Oct 21, 1986Closed
Citation 2, item 2 Other-than-serious$0$0Oct 21, 1986Closed
Citation 2, item 3 Other-than-serious$0$0Oct 21, 1986Closed
Citation 2, item 4 Other-than-serious$0$0Oct 21, 1986Closed
Citation 2, item 5 Other-than-serious$0$0Oct 21, 1986Closed
Citation 2, item 6 Other-than-serious$0$0Oct 21, 1986Closed
Citation 2, item 7
29 CFR 7920025
Other-than-serious$0$0Oct 21, 1986Closed
Citation 2, item 8 Other-than-serious$0$0Oct 21, 1986Closed
Citation 2, item 9
29 CFR 7620563
Other-than-serious$0$0Oct 21, 1986Closed
Citation 2, item 10 Other-than-serious$0$0Oct 21, 1986Closed
Citation 2, item 11 Other-than-serious$0$0Oct 21, 1986Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(e)(1)(i)

(i) A list of the hazardous chemicals known to be present using a product identifier that is referenced on the appropriate safety data sheet (the list may be compiled for the workplace as a whole or for individual work areas); and,

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.147(c)(1)

(c) General—(1) Energy control program. The employer shall establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, start up or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source, and rendered inoperative.

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.157(c)(1)

(c) General requirements. (1) The employer shall provide portable fire extinguishers and shall mount, locate and identify them so that they are readily accessible to employees without subjecting the employees to possible injury.

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.213 · Woodworking machinery

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.242 · Hand and power tools

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.333 · Working near live electrical parts

29 CFR 1926.100 · Hard hats in construction

29 CFR 6460.7050

29 CFR 7010.7050

29 CFR 7010.7600

29 CFR 7010.7650

29 CFR 7020.1610

29 CFR 7030.5030

29 CFR 7031.5010

29 CFR 7127.15

29 CFR 7410.750

29 CFR 7640.2650

29 CFR 7640.3000

29 CFR 7670.2550

29 CFR 7670.3100

Other wood window and door manufacturing employers in Oregon

Alert subscribers get notified of each newly cited employer in Oregon the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.