OSHA SearchOSHA records by employer

Ogt, LLC: OSHA inspections and violations

Mentone, Texas · All Other Support Activities for Transportation · NAICS 488999

2inspections
5citation items
$25,608current penalties
Aug 5, 2020last inspection

OSHA has inspected Ogt, LLC 2 times in Texas since 2019.

The latest one began on Aug 5, 2020 after a fatality or catastrophe, in Orla.

Those inspections ended with 5 citation items: 4 serious and 1 other-than-serious.

Penalties were first proposed at $47,760 and now stand at $25,608, 46% lower after settlements or reviews.

Lockout/tagout comes up most often in these citations: 2 items under 1910.147.

How that compares: the median penalty per cited inspection for transportation and warehousing employers since 2015 is $2,408, and Ogt, LLC averages $12,804 (2 cited inspections).

2 inspections on this page followed a fatal incident.

Ogt, LLC: OSHA citation items per year, 2019 to 2020
Citation items per year, by inspection date.

Want to know if OSHA cites Ogt, LLC again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 344869250 OPENED AUG 5, 2020Closed

Fatality or catastrophe · Complete · Safety · 125 employees at the site · Closed Jun 2, 2021

338 Rm 652 East, Orla, TX 79770 · Oil and Gas Pipeline and Related Structures Construction · OSHA's record · Phone and website on Google Maps

Incident on Aug 5, 2020 (fatal): One is killed, one is injured when trapped on lift above fir

At 10:00 a.m. on August 5, 2020, Employees #1 and #2, employed by a pipeline construction company, were working from an aerial lift and removing piping from a stabilizer tower. A fire broke out below, the aerial lift failed to operate, and the two employees were trapped on the lift. Employee #1 jumped off the lift, hit his head on a pipe, and was killed. Employee #2 also jumped off the lift, sustaining injuries in the fall. Employee #2 was transported by emergency services to the hospital, where he was admitted and treated for a fractured leg from the fall and burns from the fire.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.67(c)(2)(i) · Vehicle-mounted elevating and rotating work platforms
Serious$7,724$5,000Feb 1, 2021Final
Citation 1, item 2a
29 CFR 1910.147(f)(2)(i) · Lockout/tagout
Serious$13,516$10,000Feb 1, 2021Final
Citation 1, item 2b
29 CFR 1910.147(d)(6) · Lockout/tagout
Other-than-serious$0$0Feb 1, 2021Final

Inspection 343986212 OPENED MAY 6, 2019Closed

Fatality or catastrophe · Partial · Safety · 52 employees at the site · Closed Nov 13, 2019

6122 State Highway 302, Mentone, TX 79754 · All Other Support Activities for Transportation · OSHA's record · Phone and website on Google Maps

Incident on May 4, 2019 (fatal): Employee is killed by electrocution

At 11:00 a.m. on May 4, 2019, an employee was working by himself and using an electrical knife to clean and strip lines in a breaker box. The employee was killed when he accidentally came in contact with an energized part and was electrocuted. Normally these energized parts would have an arc flash shield in front of them but when the employee was found the shield had been removed. A horizontal cut mark was found on the outer sheath of the electrical box where the employer believed the employee had been cutting. The cutting motion would have put the employee's arm directly in front of the where the energized parts were. There were no signs of electrical gloves. Despite the breaker being locked in the off position, the entire unit was not deenergized.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.333(a)(1) · Working near live electrical parts
Serious$13,260$10,608Sep 18, 2019Final
Citation 1, item 1a
29 CFR 1910.335(a)(1)(i) · Safeguards for personnel protection
Serious$13,260$0Sep 18, 2019Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.147(d)(6)

(6) Verification of isolation. Prior to starting work on machines or equipment that have been locked out or tagged out, the authorized employee shall verify that isolation and deenergization of the machine or equipment have been accomplished.

29 CFR 1910.147(f)(2)(i)

(2) Check the work area to ensure that all employees have been safely positioned or removed from the area.

29 CFR 1910.333 · Working near live electrical parts

29 CFR 1910.333(a)(1)

(1) Deenergized parts. Live parts to which an employee may be exposed shall be deenergized before the employee works on or near them, unless the employer can demonstrate that deenergizing introduces additional or increased hazards or is infeasible due to equipment design or operational limitations. Live parts that operate at less than 50 volts to ground need not be deenergized if there will be no increased exposure to electrical burns or to explosion due to electric arcs.

29 CFR 1910.335 · Safeguards for personnel protection

29 CFR 1910.67 · Vehicle-mounted elevating and rotating work platforms

Other all other support activities for transportation employers in Texas

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.